Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Surg ; 12(5): 426-31, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24681094

RESUMO

BACKGROUND: The aim of this study was to evaluate colonic wall changes and enteric neuropathy in patients with either uncomplicated (UDD) or complicated diverticular disease (CDD). Furthermore, we evaluated the presence of an anatomic sphincter at the rectosigmoid junction (RSJ). METHODS: Samples of colonic tissue from fifteen patients with UDD, fifteen patients with CDD and fifteen patients as control were collected. Collagen quotient I/III was measured with the Sirius-red test, expression of MMP-1, MMP-13, innervation (S100), proliferation (Ki67) and apoptosis (TUNEL) in the colonic wall were investigated by immunohistochemical studies. Furthermore, measurements of the different layers were performed to investigate the RSJ. RESULTS: Patients with either UDD or CDD had lower collagen I/III quotients compared to the control group, significant for CDD (p = 0.007). For MMP-1 and MMP-13 only a slight increase for patients with CDD was found. The percentage of proliferating (Ki67) and apoptotic (TUNEL) cells was significantly higher for patients with CDD than in the control group (p = 0.016; p = 0.037). Upon investigating the S100-expression a significant reduce in glial cells density was found in the myenteric and mucosal plexus for both groups (UDD and CDD) compared to the control group. Measurements of the different colon layers oral, aboral and at the RSJ revealed equal values. CONCLUSIONS: This study has shown that colonic wall changes and enteric neuropathy seem to play a role in the pathogenesis of colonic diverticulosis. None of our results suggest a predisposition for a complicated diverticular disease. Furthermore, the presence of an anatomic sphincter at the rectosigmoid junction could not be detected.


Assuntos
Colo/metabolismo , Colo/patologia , Doença Diverticular do Colo/metabolismo , Doença Diverticular do Colo/patologia , Idoso , Apoptose/fisiologia , Estudos de Casos e Controles , Colágeno/metabolismo , Humanos , Antígeno Ki-67/metabolismo , Metaloproteinase 1 da Matriz/metabolismo , Metaloproteinase 13 da Matriz/metabolismo , Pessoa de Meia-Idade , Neuroglia/metabolismo , Neuroglia/patologia , Reto/metabolismo , Reto/patologia
2.
Endoscopy ; 42(7): 599-602, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20432210

RESUMO

The incidence of clinically significant anastomotic leaks after upper gastrointestinal surgery is approximately 4 % - 20 %, and the associated mortality can be as high as 80 %. Depending on the clinical presentation, the treatment options are surgery, conservative treatment with external drainage, or endoscopic treatment. This report presents 39 cases of clinically apparent anastomotic leaks or fistulas after surgery for upper gastrointestinal cancers that were treated by endoscopy with insertion of fibrin glue alone (n = 24) or with a combination of Vicryl plug and fibrin glue (n = 15). Thirteen of the 15 patients who underwent Vicryl/fibrin treatments showed complete healing of the anastomotic leak or fistula after one to four sessions. Long-term follow-up results are presented. Postoperative upper gastrointestinal fistulas or anastomotic leaks can be managed successfully with low morbidity by means of endoscopic insertion of Vicryl mesh with fibrin glue, thereby avoiding repeated major surgery and its associated risks.


Assuntos
Fístula do Sistema Digestório/terapia , Neoplasias Esofágicas/cirurgia , Esofagectomia/efeitos adversos , Adesivo Tecidual de Fibrina/uso terapêutico , Gastrectomia/efeitos adversos , Telas Cirúrgicas , Algoritmos , Anastomose Cirúrgica/efeitos adversos , Fístula do Sistema Digestório/etiologia , Seguimentos , Fístula Gástrica/etiologia , Fístula Gástrica/terapia , Humanos , Fístula Intestinal/etiologia , Fístula Intestinal/terapia , Poliglactina 910 , Complicações Pós-Operatórias , Cicatrização
3.
Rofo ; 177(5): 632-6, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15871077

RESUMO

PURPOSE: In-vitro evaluation of a new caval filter (Cook Celect Filter) developed for delayed percutaneous retrieval in comparison to the Gunther Tulip filter. MATERIALS AND METHODS: The new Celect filter is constructed on the basis of the Tulip filter and consists of 4 primary anchoring legs and additional 8 thinner secondary wires to stabilize the filter and to guarantee adequate filtering efficiency. The filtering wires are of the same amount and equal distribution as the filtering wires of the Tulip filter. The secondary wires are arranged in such a way that percutaneous filter retrieval should be possible even if the wires are incorporated into the caval wall. In a flow model (tube size ø15-, ø22- and ø30 mm), the filter was exposed to single and multiple emboli (blood clots) of different sizes (3 x 5, 3 x 10, 5 x 10, 3 x 20, 5 x 20, 7 x 10, 7 x 20 to 10 x 24 mm) to analyse the embolus capturing efficiency under different conditions including eccentric and concentric, horizontal and vertical positions in comparison to the Tulip filter. All testing was carried out in SPSS analytic software; statistical significance was assumed for p-values < 0.05. RESULTS: The in-vitro embolus capturing efficiency of the Celect filter proved to be equivalent to the Tulip filter. In the single-embolus test, 91.6 % of the clots were captured by the Celect filter and 87.2 % by the Tulip filter (p = 0.042). Large clots ranging from 7 x 10 to 10 x 24 mm were captured in all cases, whereas the capture rates for the 3 x 5-mm and 3 x 10-mm clots were lower. The filters captured significantly more clots in the concentric than in the eccentric location. There was no significant difference between the overall capture rates of the two filters in the multi-clot test (72.2 % vs. 75.1 %), which showed deterioration of filter function during multiple clot exposure. With the 15-mm tube, the Celect filter had a significantly higher capture rate than the Tulip filter, whereas it was lower with the ø30-mm tube. There was no significant difference between the filters in a ø22-mm tube. The pressure gradient across the filters when exposed to blood clots ranged from 4.9 - 7.4 mm Hg for the Celect filter and 5.7 - 6.8 mm Hg for the Tulip filter in the single-embolus testing. There was no significant difference in the multi-clot tests. CONCLUSION: The new Celect filter showed similar in-vitro capture properties as the Gunther Tulip filter and deserves further in-vivo testing.


Assuntos
Prótese Vascular , Embolia/prevenção & controle , Embolia/cirurgia , Análise de Falha de Equipamento/métodos , Filtros de Veia Cava , Veia Cava Inferior/fisiopatologia , Veia Cava Inferior/cirurgia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Hemofiltração/instrumentação , Hemofiltração/métodos , Humanos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...