Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930026

RESUMO

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

2.
Genes (Basel) ; 15(5)2024 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-38790165

RESUMO

Adams-Oliver syndrome is a rare inherited condition characterized by scalp defects and limb abnormalities. It is caused by variants in different genes such as ARHGAP31. Here, we used an interdisciplinary approach to study a family with lower limb anomalies. We identified a novel variant in the ARHGAP31 gene that is predicted to result in a truncated protein with a constitutively activated catalytic site due to the loss of 688 amino acids involved in the C-terminal domain, essential for protein auto-inhibition. Pathogenic variants in ARHGAP31 exon 12, leading to a premature protein termination, are associated with Adams-Oliver syndrome. Bioinformatic analysis was useful to elucidate the impact of the identified genetic variant on protein structure. To better understand the impact of the identified variant, 3D protein models were predicted for the ARHGAP31 wild type, the newly discovered variant, and other pathogenetic alterations already reported. Our study identified a novel variant probably involved in Adams-Oliver syndrome and increased the evidence on the phenotypic variability in patients affected by this syndrome, underlining the importance of translational research, including experimental and bioinformatics analyses. This strategy represents a successful model to investigate molecular mechanisms involved in syndrome occurrence.


Assuntos
Displasia Ectodérmica , Proteínas Ativadoras de GTPase , Deformidades Congênitas dos Membros , Fosfoproteínas , Dermatoses do Couro Cabeludo , Feminino , Humanos , Masculino , Displasia Ectodérmica/genética , Displasia Ectodérmica/patologia , Proteínas Ativadoras de GTPase/genética , Deformidades Congênitas dos Membros/genética , Mutação , Linhagem , Fenótipo , Dermatoses do Couro Cabeludo/genética , Dermatoses do Couro Cabeludo/congênito , Dermatoses do Couro Cabeludo/patologia
3.
JACC Case Rep ; 29(7): 102259, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38645284

RESUMO

Paravalvular regurgitation remains a frequent finding after transcatheter aortic valve replacement and is associated with unfavorable outcomes if more-than-mild grade. In this case, a patient underwent a third transcatheter aortic valve replacement procedure for worsening symptoms due to severe paravalvular regurgitation. The case underlines the role of preprocedural planning in achieving treatment success.

4.
JACC Cardiovasc Interv ; 17(6): 727-737, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38456879

RESUMO

BACKGROUND: Coronary re-engagement after transcatheter aortic valve replacement (TAVR) using self-expanding transcatheter heart valves (THVs) systematically implanted using commissural alignment (CA) techniques has been poorly investigated. OBJECTIVES: The aim of this study was to evaluate unsuccessful coronary cannulation, and its predictors, after TAVR using self-expanding devices implanted using CA techniques. METHODS: RE-ACCESS 2 (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent 2) was an investigator-driven, single-center, prospective study that enrolled consecutive TAVR patients receiving Evolut and ACURATE THVs implanted using CA techniques. The primary endpoint was unsuccessful coronary cannulation after TAVR. The secondary endpoint was the identification of postprocedural predictors of unfeasible, selective coronary ostia re-engagement on computed tomographic angiography performed after TAVR. RESULTS: Among 127 patients enrolled from September 2021 to December 2022, 7 (5.5%) had unsuccessful coronary cannulation after TAVR, and 6 of them received Evolut THVs (7.5% vs 2.3%; P = 0.26). Failure of left coronary artery cannulation was similar between Evolut and ACURATE THVs (2.5% vs 2.1%; P = 1.00), whereas that of right coronary artery cannulation was prevalent in the Evolut group (6.3% vs 0.0%; P = 0.16). Coronary overlap was associated with the inability to selectively cannulate the right coronary artery (OR: 5.6; 95% CI: 1.2-25.8; P = 0.03), but not in ACURATE recipients (P = 0.39). Severe misalignment of Evolut THVs was associated with the inability to selectively cannulate both coronary arteries (OR: 24.7; 95% CI: 1.9-312.9; P = 0.01). CONCLUSIONS: Unsuccessful coronary cannulation after TAVR using self-expanding THVs implanted using CA techniques was reported in 5.5% of cases, with the majority involving the Evolut THV. Commissural misalignment affected coronary cannulation after TAVR mostly in Evolut recipients.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Fatores de Risco , Desenho de Prótese , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Cateterismo
5.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479968

RESUMO

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia
6.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506737

RESUMO

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Catéteres , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valvas Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos
7.
Am J Cardiol ; 219: 60-70, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38401656

RESUMO

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Fatores Sexuais , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia
8.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982161

RESUMO

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Desenho de Prótese
9.
Foods ; 12(20)2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37893774

RESUMO

The possibility of industrial exploitation of winemaking products, as for all byproducts of vegetal origin, constantly deals with a raw material (grape pomace, GP) whose chemical composition and functional properties vary over time depending on the varietal and geographical origin of the grapes, the climatic conditions (vintage effect), and the winemaking technique. This work studied the compositional variability of polyphenolic skin and seed extracts from GP derived from white and red winemaking of different Italian grape varieties. The total polyphenolic content (GAE), the main classes of polyphenolic compounds, and the DPPH index were determined. Seed extracts were always richer in total polyphenols and condensed tannins and had higher antiradical activity (DPPH) than skin extracts: 144-298 mg GAE/g d.w. extract for skins and 327-540 mg GAE/g for seeds; the DPPH values were 1.77-3.40 mg AAE/g for skins and 3.10-10.48 mg AAE/g for seeds. Furthermore, it was verified that the evaluation of the GAE index of seed extracts, offering a good estimate of the antiradical properties (DPPH index), could represent a simple and rapid method for selecting the best lots of seeds to be used. Conversely, GP skins could be used as flour in the food industry due to their high content of dietary fiber and the presence of flavonols, which possess very interesting functional properties. Important differences in the flavonols profile were observed both between cultivars and between unfermented and fermented pomace.

12.
Minerva Cardiol Angiol ; 71(3): 311-320, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36305774

RESUMO

BACKGROUND: The safety of concomitant percutaneous coronary intervention (PCI) during transcatheter aortic valve implantation (TAVI) setting is still highly debated. This study aimed to assess the safety and the effectiveness of TAVI and PCI performed in the same session compared with TAVI alone. METHODS: Patients with severe aortic stenosis and coronary artery disease (CAD) (N.=786) who underwent TAVI from June 2007 to April 2021 were divided into two groups: patients who underwent TAVI alone (N.=633) and patients treated with TAVI and concomitant PCI (N.=153). The propensity-score matching adjustment was used to account for baseline confounding variables. RESULTS: A total of 302 TAVI with CAD patients (151 matched pairs), undergoing either isolated TAVI or TAVI+PCI were compared. In-hospital death (6% vs. 4%; P=0.427), stroke (2% vs. 0.7%; P=0.314), myocardial infarction (MI) (0% vs. 0.7%; P=0.317), major and life-threatening bleeding (14.6% vs. 15.9%; P=0.749), and acute kidney injury (9.3% vs. 10.6%; P=0.700) were similar for both groups. At 3 years, the rates of all-cause death (25.2% vs. 19.2%; P=0.615), the composite endpoints of all-cause death and MI (27.2% vs. 21.2%; P=0.699) and all-cause death, MI, and stroke (28.5% vs. 22.5%; P=0.739) were also comparable between the two groups. Achieving complete coronary revascularization in the TAVI setting did not impact on long-term mortality (P=0.257). CONCLUSIONS: In patients with severe aortic stenosis and CAD, concomitant TAVI and PCI was as safe and effective as TAVI alone up to 3-year follow-up.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Mortalidade Hospitalar , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Doença da Artéria Coronariana/cirurgia , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/cirurgia , Acidente Vascular Cerebral/complicações
13.
Eur Heart J Suppl ; 24(Suppl I): I170-I174, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36380774

RESUMO

New insights into the natural history and pathophysiology of patients with aortic stenosis (AS), coupled with the dramatic evolution of transcatheter aortic valve implantation (TAVI), are fuelling intense interest in the management of asymptomatic patients with severe AS. This patient presenting for elective intervention poses a unique challenge. These patients are not traditionally offered surgical aortic valve replacement or TAVI given their lack of symptoms; however, they are at increased risk given the severity of their AS. Furthermore, clinical experience has shown that symptoms can be challenging to ascertain in many sedentary, deconditioned, and/or elderly patients. In addition, evolving data based on imaging and biomarker evidence of adverse ventricular remodelling, hypertrophy, inflammation, or fibrosis may radically transform existing clinical decision paradigms. However, management of asymptomatic severe AS is otherwise controversial and the decision to intervene requires careful assessment of the benefits and risks in an individual patient. Further randomized trials [EARLY TAVI (NCT03042104), AVATAR (NCT02436655), EVOLVED (NCT03094143)] will help determine future recommendations.

14.
JACC Cardiovasc Interv ; 15(23): 2398-2407, 2022 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-36121242

RESUMO

BACKGROUND: The latest iterations of devices for transcatheter aortic valve replacement (TAVR) have brought refinements to further improve patient outcomes. OBJECTIVES: This study sought to compare early outcomes of patients undergoing TAVR with the self-expanding (SE) Evolut PRO/PRO+ (Medtronic, Inc) or balloon-expandable (BE) Sapien 3 ULTRA (Edwards Lifesciences) devices. METHODS: The OPERA-TAVI (Comparative Analysis of Evolut PRO vs Sapien 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry collected data from 14 high-volume centers worldwide on patients undergoing TAVR with SE or BE devices. After excluding patients who were not eligible for both devices, patients were compared using 1:1 propensity score matching. The primary efficacy and safety outcomes were Valve Academic Research Consortium-3 device success and early safety, respectively. RESULTS: Among 2,241 patients eligible for the present analysis, 683 pairs of patients were matched. The primary efficacy outcome did not differ between patients receiving SE or BE transcatheter aortic valves (SE: 87.4% vs BE: 85.9%; P = 0.47), but the BE device recipients showed a higher rate of the primary safety outcome (SE: 69.1% vs BE: 82.6%; P < 0.01). This finding was driven by the higher rates of permanent pacemaker implantation (SE: 17.9% vs BE: 10.1%; P < 0.01) and disabling stroke (SE: 2.3% vs BE: 0.7%; P = 0.03) in SE device recipients. On post-TAVR echocardiography, the rate of moderate to severe paravalvular regurgitation was similar between groups (SE: 3.2% vs BE: 2.3%; P = 0.41), whereas lower mean transvalvular gradients were observed in the SE cohort (median SE: 7.0 vs BE: 12.0 mm Hg; P < 0.01). CONCLUSIONS: The OPERA-TAVI registry showed that SE and BE devices had comparable Valve Academic Research Consortium-3 device success rates, but the BE device had a higher rate of early safety. The higher permanent pacemaker implantation and disabling stroke rates in SE device recipients drove this composite endpoint.


Assuntos
Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Radiat Prot Dosimetry ; 198(9-11): 670-674, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005969

RESUMO

The Microtron MT25 is a cyclic electron accelerator with a Kapitza resonator, maximum beam energy of 25 MeV, standard repetition frequency of 423 Hz, pulse length of 3.5 µs and mean current of 30 µA. Studies at conventional particle accelerators allow to understand the response of dosemeters in known and controllable radiation fields. Subsequently, it is possible to develop models and predict their behavior in complex radiation fields, such as those generated at laser and FLASH facilities. Therefore, response of thermally and optically stimulated luminescence detectors outside of the beam was studied at the Microtron MT25. The detectors were placed on a Plexiglas phantom inside a lead and iron bunker to shield-off background radiation. In addition, GAFChromic™ films and track detectors were used. Two irradiations were performed: with and without an 8-cm thick polyethylene moderator. This paper presents a comparison of the responses of the different detection systems.


Assuntos
Elétrons , Aceleradores de Partículas , Luminescência , Imagens de Fantasmas
16.
G Ital Cardiol (Rome) ; 23(6): 461-468, 2022 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-35674037

RESUMO

BACKGROUND: To assess the longitudinal changes in transcatheter aortic valve implantation (TAVI) practice and patients' outcomes in a high-volume Italian center. METHODS: We analyzed all patients undergoing TAVI at our Institution from June 2007 to August 2021. We stratified the overall population considering four time periods according to procedural advancements and changes in clinical practice: period 1 (2007-2009, n=107) vs period 2 (2010-2014, n=449) vs period 3 (2015-2019, n=864) vs period 4 (2019-2021, n=638). Baseline and procedural characteristics, and in-hospital outcomes among the four groups were compared. RESULTS: A total of 2058 patients underwent TAVI receiving all the available devices. Patients had a median age of 82 years (78-85) with no differences among time periods. A stepwise reduction of median Society of Thoracic Surgeons mortality risk score (3.7 [2.8-5.3] vs 3.6 [2.6-5.4] vs 3.6 [2.5-5.5] vs 3.3 [2.2-4.9]; p=0.01) was observed. In-hospital all-cause-death (7.5% vs 5.1% vs 2.9% vs 3.0%; p<0.05), major stroke (4.7% vs 0.7% vs 1.0% vs 0.8%; p<0.05), major vascular complications (17.8% vs 8.7% vs 10.5% vs 5.8%; p<0.05) and permanent pacemaker implantation (23.4% vs 12.0% vs 8.7% vs 8.8%; p<0.05) rates significantly lowered over time. Device success markedly improved (80.4% vs 87.1% vs 95.0% vs 96.3%; p<0.05) with significant improvement of paravalvular regurgitation after TAVI (moderate-to-severe 16.8% vs 8.1% vs 0.7% vs 0.2%; mild 61.4% vs 38.2% vs 38.5% vs 25.6%; p<0.05). CONCLUSIONS: All-cause death and in-hospital outcomes of patients undergoing TAVI significantly improved accordingly to technical advancements and changes in clinical practice over 15-year experience.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
18.
JACC Case Rep ; 4(2): 83-86, 2022 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-35106489

RESUMO

Achieving patient-specific commissural alignment of transcatheter aortic valves is particularly important to ensure coronary reaccess after transcatheter aortic valve implantation. Nevertheless, in case of uncommon origin of coronary arteries, commissural alignment could be counterproductive. This case shows how alignment techniques could serve to intentionally misalign the neocommissures in this subset of patients. (Level of Difficulty: Intermediate.).

19.
Int J Cardiol ; 352: 190-194, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35077726

RESUMO

BACKGROUND: The coronavirus 2019 (COVID-19) pandemic upset healthcare systems and their logistics worldwide. We sought to assess safety and effectiveness of an optimized logistics for transcatheter aortic valve implantation (TAVI) pathway developed during the COVID-19 pandemic. METHODS: This is a retrospective analysis. An optimized TAVI logistics based on performing TAVI work-up and procedure during the same hospitalization was used during the COVID-19 pandemic. In-hospital and 30-day outcomes of patients treated during the pandemic were compared with an historical cohort of patients undergoing TAVI with staged work-up before the pandemic within an homogeneous timeframe. RESULTS: Of 536 patients, 227 (42.4%) underwent TAVI during the COVID-19 pandemic with a reduction of 26.5% compared to the pre-pandemic period (n = 309). The median age was 81 (77-85) years and STS score was 3.4 (2.2-5.6)%. Lower rates of in-hospital major vascular complications (2.2% vs. 8.7%; p < 0.01) and life-threatening bleeding (0.4% vs. 4.2%; p = 0.01) were reported in the COVID-19 period, whereas no difference in acute kidney injury (7.0% vs. 7.4%, p = 0.85) rate was reported between COVID-19 and pre-COVID-19 periods. No difference in 30-day rates of all-cause death (4.0 vs. 4.5, p = 0.75) and of major adverse cardiovascular events (4.0 vs. 6.1, p = 0.26) were reported between COVID-19 and pre-COVID-19 periods. CONCLUSIONS: The use of optimized single-hospitalization logistics for TAVI workup and procedure developed during the COVID-19 pandemic, showed to be as safe and effective as the two-stage TAVI pathway previously adopted, allowing the minimization of potential exposure to COVID-19 infection and shortening times to treatment for severely symptomatic patients.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , COVID-19/epidemiologia , Atenção à Saúde , Humanos , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
20.
Pediatr Res ; 91(7): 1890-1896, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34344991

RESUMO

BACKGROUND: Maternal dietary habits are contributors of maternal and fetal health; however, available data are heterogeneous and not conclusive. METHODS: Nutrient intake during pregnancy was assessed in 503 women with uncomplicated pregnancies, using the validated Food Frequency Questionnaire developed by the European Prospective Investigation into Cancer and Nutrition (EPIC-FFQ). RESULTS: In all, 68% of women had a normal body mass index at the beginning of pregnancy, and 83% of newborns had an appropriate weight for gestational age. Maternal pre-pregnancy body mass index (BMI), gestational weight gain (GWG), and placental weight were independently correlated with birth weight. GWG was not related to the pre-pregnancy BMI. EPIC-FFQ evaluation showed that 30% of women adhered to the European Food Safety Authority (EFSA) ranges for macronutrient intake. In most pregnant women (98.1%), consumption of water was below recommendations. Comparing women with intakes within EFSA ranges for macronutrients with those who did not, no differences were found in BMI, GWG, and neonatal or placental weight. Neither maternal nor neonatal parameters were associated with the maternal dietary profiles. CONCLUSIONS: In our population, maternal pre-pregnancy BMI, GWG, and placental weight are determinants of birth weight percentile, while no association was found with maternal nutrition. Future studies should explore associations through all infancy. IMPACT: Maternal anthropometrics and nutrition status may affect offspring birth weight. In 503 healthy women, maternal pre-pregnancy body mass index (BMI), gestational weight gain (GWG), and placental weight were independently correlated to neonatal birth weight. GWG was not related to the pre-pregnancy BMI. In all, 30% of women respected the EFSA ranges for macronutrients. Neither maternal nor neonatal parameters were associated with maternal dietary profiles considered in this study. Maternal pre-pregnancy BMI, GWG, and placental weight are determinants of neonatal birth weight percentile, while a connection with maternal nutrition profiles was not found.


Assuntos
Ganho de Peso na Gestação , Aumento de Peso , Peso ao Nascer , Índice de Massa Corporal , Ingestão de Alimentos , Feminino , Humanos , Recém-Nascido , Placenta , Gravidez , Resultado da Gravidez , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...