Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-36423594

RESUMO

INTRODUCTION: High indoxyl sulfate (IS) concentration is a serious problem for patients with CKD increasing the risk of cardiovascular diseases and CKD progression. Thus, the methods of decreasing the toxin concentrations are highly desired. The study aimed to discover the role of selected intestine related factors on IS concentration. METHODS: We evaluated the impact of ABCG2 and ABCC2 polymorphisms influencing activity and protein intake by normalized protein catabolic rate. Additionally, we examined the relation of IS and uric acid (UA), that can share common elimination transporters. A monocentric, prospective, open cohort pilot study was performed on 108 patients undergoing dialysis treatment. RESULTS: The positive effect of residual diuresis on the reduction of IS levels was confirmed (p = 0.005). Also, an increase in IS depending on the dietary protein intake was confirmed (p = 0.040). No significant correlation between ABC gene polymorphisms was observed either, suggesting the negligible role of ABCG2 and ABCC2 in the elimination of IS in small bowel. The significant difference was observed for UA where ABCG2 421C>A (rs72552713) gene polymorphism was higher (505.3 µmol/L) in comparison with a wild type genotype (360.5 µmol/L). Discussion/ Conclusion: No evidence of bowel elimination pathway via ABCC2 and ABCG2 transporters was found in renal replacement therapy patients.

2.
J Cardiovasc Transl Res ; 14(6): 1043-1050, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33974231

RESUMO

The evidence supporting surgical aneurysmectomy in ischemic heart failure is inconsistent. The aim of the study was to describe long-term effect of minimally invasive hybrid transcatheter and minithoracotomy left ventricular (LV) reconstruction in patients with ischemic cardiomyopathy. Twenty-three subjects with transmural anterior wall scarring, LV ejection fraction 15-45%, and New York Heart Association class ≥ II were intervened using Revivent TC anchoring system. LV end-systolic volume index was reduced from 73.2 ± 27 ml at baseline to 51.5 ± 22 ml after 6 months (p < 0.001), 49.9 ± 20 ml after 2 years (p < 0.001), and 56.1 ± 16 ml after 5 years (p = 0.047). NYHA class improved significantly at 5 years compared to baseline. Six-min walk test distance increased at 2 years compared to the 6-month visit. Hybrid LV reconstruction using the anchoring system provides significant and durable LV volume reduction during 5-year follow-up in preselected patients with ischemic heart failure. Legend: Hybrid left ventricular reconstruction using the anchoring system provides significant and durable LV volume reduction throughout 5-year follow-up in preselected patients with ischemic heart failure.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiomiopatias/cirurgia , Isquemia Miocárdica/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Disfunção Ventricular Esquerda/cirurgia , Cardiomiopatias/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Estudos Prospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Teste de Caminhada
3.
J Cardiovasc Electrophysiol ; 32(5): 1367-1375, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33682228

RESUMO

INTRODUCTION: When cardiac magnetic resonance (MR) is performed after previous leadless transcatheter pacemaker implantation, an image distortion has to be expected in the heart region and evaluation of myocardial tissue can be affected. In this clinical prospective study, we aim to assess the extent and impact of this artifact on individual ventricular segments and compare it to conventional pacing devices. METHODS: Total of 20 patients with leadless pacemaker placed in the right ventricle underwent cardiac MR imaging in a 1.5 Tesla scanner. A multiplanar segmentation was used to demarcate the left and right ventricular myocardium as well as the pacemaker-caused image artifact in systolic and diastolic time frames. Artifact size and its relative influence on myocardial segments were quantitatively assessed and expressed in AHA-17 model. RESULTS: Implanted leadless pacemaker caused an image artifact with a volume of 48 ± 5 ml. Most distorted were the apical septal (53 ± 23%), apical inferior (30 ± 18%), and midventricular inferoseptal (30 ± 20%) segments. The artifact intersection with basal and lateral segments was none or negligible (up to 2%). The portion of left ventricular (LV) myocardium affected by the artifact was significantly higher in systole (8 ± 4%) compared to diastole (10 ± 3%; p < .001). CONCLUSION: Implantation of leadless pacemaker represents no obstacle for cardiac MR imaging but causes an image artifact located mostly in septal, inferoseptal, and anteroseptal segments of apical and midventricular LV myocardium. With the exception of the apex, diastolic timing reduces the image distortion of all segments and improves global ventricular assessment.


Assuntos
Artefatos , Marca-Passo Artificial , Coração , Humanos , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
4.
Dis Markers ; 2018: 3985861, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30186534

RESUMO

Indoxyl sulfate has been identified as a major factor in the dysregulation of several genes. It is classified as a poorly dialyzable uremic toxin and thus a leading cause in the poor survival rate of dialysis patients. A monocentric, prospective, open cohort study was performed in 43 male patients undergoing chronic renal replacement therapy in a single hemodialysis center. The aim of the study was to determine the influence of acetate- versus citrate-buffered dialysis fluids in hemodialysis (HD) and postdilution hemodiafiltration (HDF) settings on the elimination of indoxyl sulfate. Also, additional factors potentially influencing the serum concentration of indoxyl sulfate were evaluated. For this purpose, the predialysis and postdialysis concentration ratio of indoxyl sulfate and total protein was determined. The difference was of 1.15 (0.61; 2.10), 0.89 (0.53; 1.66), 0.32 (0.07; 0.63), and 0.44 (0.27; 0.77) µmol/g in acetate HD and HDF and citrate HD and HDF, respectively. Acetate HD and HDF were superior when concerning IS elimination when compared to citrate HD and HDF. Moreover, residual diuresis was determined as the only predictor of lower indoxyl sulfate concentration, suggesting that it should be preserved as long as possible. This trial is registered with EU PAS Register of Studies EUPAS23714.


Assuntos
Acetatos/farmacologia , Ácido Cítrico/farmacologia , Soluções para Diálise/farmacologia , Indicã/sangue , Diálise Renal/métodos , Idoso , Bicarbonatos , Ácido Cítrico/sangue , Soluções para Diálise/química , Hemodiafiltração/métodos , Humanos , Indicã/farmacocinética , Nefropatias/terapia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Kidney Blood Press Res ; 40(1): 13-21, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25661822

RESUMO

BACKGROUND/AIMS: In recent years, one of technical attempts to improve biocompatibility and tolerability of the hemodialysis procedure is the substitution of acetate in dialysis solution with citrate. The aim of our study was to compare two dialysis solutions: traditional bicarbonate dialysis solution containing acetate (3 mmol/L) (solution A); and (solution C) commercially produced citrate-enriched bicarbonate dialysis solution (0.8 mmol/L citrate). METHODS: Patients from a single hemodialysis center (N=126) were included in the study. Both conventional low-flux hemodialysis and on-line hemodiafiltration procedures were studied. Both dialysis solutions contained identical calcium (1.5 mmol/L) and magnesium (0.5 mmol/L) concentrations. RESULTS: Parathyroid hormone (iPTH) concentration decreased during procedures with solution A by 64%. On the contrary, when solution C was used, iPTH concentration increased insignificantly by 4%. For solution A, serum calcium and magnesium increased during procedures in patients with predialysis concentrations lower than 2.33 and 0.76 mmol/L, respectively. In procedures with dialysis solution C these concentrations were significantly lower: 2.19 mmol/L for Ca and 0.68 mmol/L for Mg. CONCLUSION: Our study clearly shows that the substitution of part of acetate with citrate in dialysis solution significantly influences changes of serum calcium, magnesium and parathyroid hormone concentrations during hemodialysis and hemodiafiltration procedures.


Assuntos
Cálcio/sangue , Ácido Cítrico/administração & dosagem , Soluções para Diálise/administração & dosagem , Magnésio/sangue , Hormônio Paratireóideo/sangue , Diálise Renal/tendências , Idoso , Biomarcadores/sangue , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
6.
Ren Fail ; 32(1): 21-6, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20113261

RESUMO

BACKGROUND: Cardiovascular mortality in hemodialysis (HD) patients remains high despite improvements in HD technique such as dialysis adequacy, dialysis fluid purity, and membrane biocompatibility. Optimal fluid balance to maintain optimal hemodynamic stability during hemodialysis (HD) procedure is essential. At the present time, hemodynamic stability is conventionally assessed as stability of macrocirculation, especially as maintenance of systemic blood pressure with no attention paid to peripheral perfusion. Peripheral ischemic vascular disease represents a serious problem with high mortality and morbidity. We estimated skin microcirculation changes during HD using new device, Laser Doppler Line Scanner (Moor Instruments, Devon, UK). AIMS: The aims were to introduce the novel method of detection of skin perfusion changes during hemodialysis and to evaluate possible relationship of these to ultrafiltration as well as to selected biochemical characteristics. METHODS: In 36 hemodynamically stable patients, we performed paired measurements of skin blood flow in both hands before and during HD with registering the time of dialysis and the total ultrafiltration achieved. RESULTS: We found a significant decrease in a majority of the evaluated areas. However, the skin blood flow change was not homogenous as it decreased more on the fingers. CONCLUSION: To our knowledge, this is the first study when the microcirculatory changes during hemodialysis are demonstrated and evaluated in large skin surface area, and showing not only a decrease in a majority of areas but also the heterogeneity of the changes.


Assuntos
Microcirculação , Diálise Renal , Pele/irrigação sanguínea , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...