1.
Gynecol Obstet Fertil Senol ; 48(11): 814-819, 2020 11.
Artigo em Francês | MEDLINE | ID: mdl-32184177

RESUMO

The Odon Device™ has been described in the literature since 2013 and the World Health Organization supports its development through the Human Reproduction Program. This innovative device could be easier to use than usual instruments and could be an alternative to caesarean section during the second stage of labor, especially in countries where access to obstetric care is limited. The aim of the Odon Device™ is to position an air cuff over the fetal head, past its widest point (around the level of the fetal mouth anteriorly and the nape of the fetal neck posteriorly). Three mechanical principles favor the progression of the fetal head with the Odon Device™: partial propulsion, limited flexion and traction. Preliminary clinical studies on animals and simulators are reassuring and show that an appropriate use is no more at risk than the vaccum or forceps. A phase 1 study was conducted in Argentina and South Africa between 2011 and 2017. The reported failure rate was 29%, of which 77% was secondary to a mechanical failure of one of the components of the device. Improvements concerning the applicator, the handles and the inflatable air cuff have been made to the device. Phase II of the clinical research program began in 2018 and includes two studies in two different centers: The ASSIST Study in Bristol, England, and The BESANCON ASSIST Study, Besançon, France.


Assuntos
Extração Obstétrica , Trabalho de Parto , Animais , Cesárea , Feminino , Feto , Cabeça , Humanos , Gravidez
2.
Arch Pediatr ; 20(9): 1022-7, 2013 Sep.
Artigo em Francês | MEDLINE | ID: mdl-23896088

RESUMO

The timing of umbilical cord clamping remains controversial. Although most maternity wards use the early clamping (5-15s), randomized studies and meta-analyses have demonstrated the benefit of delayed clamping for term and preterm newborn infants over the past 10 years. Indeed, placentofetal transfusion of 20-30 ml/kg in 2-3 min improves the iron status of term infants and prevents infant hypochromic anemia. Infant anemia is a public health problem in many developing countries. For preterm newborns, placental transfusion for 45 s or milking the cord for 15 s improves cardiovascular adaptation, with better hemodynamic stability, as well as decreased intraventricular hemorrhages, need for transfusion, and late-onset sepsis. A new look at this symbolic act is needed and professionals need to be persuaded of the importance of the "wait a minute" policy for a better physiological delivery.


Assuntos
Circulação Placentária/fisiologia , Cordão Umbilical , Adaptação Psicológica , Anemia Neonatal/prevenção & controle , Transfusão de Sangue/estatística & dados numéricos , Fenômenos Fisiológicos Cardiovasculares , Hemorragia Cerebral/prevenção & controle , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro/sangue , Ligadura/normas , Gravidez , Sepse/prevenção & controle , Fatores de Tempo