Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Daru ; 28(1): 57-64, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31808068

RESUMO

BACKGROUND: Chlorpheniramine (CPA), thanks to its relatively lower side effects, is a widely prescribed medicine for alleviating allergic symptoms as well as some medical emergencies. Owning to this extensive use, many efforts have been directed to measure chlorpheniramine both in vivo and in vitro. High performance liquid chromatography (HPLC), both normal and reverse phase, as well as spectrochemical and electrochemical methods are analytical approaches which have been extensively exploited for determination of CPA. Among them, electrochemical techniques have found elegant place for analysis of CPA due to simplicity, sensitivity and ease of instrumentation. METHODS: Herein, we have reported the preparation and characterization of a biosensor by immobilization of double-stranded DNA on the surface of overoxidizedpolypyrrole-reduced graphene oxide modified pencil graphite electrode (ds-DNA-PPyox/RGO/PGE) as well as its novel usability in measurement of chlorpheniramine (CPA). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), UV-Vis spectroscopy and differential pulse voltammetry (DPV) were exploited in order to characterize and evaluate the performance of the proposed biosensor. RESULTS: Final results showed that proposed strategy for modification of PGE introduces an ultra-sensitive biosensor for CPA which offers the best detection limitamong all previously reported electrochemical sensors for CPA. Taking advantage of this biosensor for determination of CPA, a wide linear dynamic range from 0.05 to 200 µM, and a low limit of detection 0.023 µM were obtained by using DPV method. Usability of this biosensor was also confirmed by determination of CPA in tablet and spiked urine samples. CONCLUSIONS: Overoxidized polypyrrole-reduced graphene oxide offered a suitable substrate for immobilization of ds-DNA by which a new biosensor for determination of CPA was fabricated. Proposed biosensor can successfully be used for determination of CPA in urine samples taking advantage of electroanalytical methods. Graphical abstract.


Assuntos
Técnicas Biossensoriais , Clorfeniramina/análise , DNA/química , Grafite/química , Antagonistas dos Receptores Histamínicos H1/análise , Ácidos Nucleicos Imobilizados/química , Polímeros/química , Pirróis/química , Clorfeniramina/química , Técnicas Eletroquímicas , Antagonistas dos Receptores Histamínicos H1/química , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...