Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Int Ophthalmol ; 38(6): 2451-2462, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29075940

RESUMO

PURPOSE: The aim of this pilot study was to evaluate a new semiautomatic procedure to assess in vivo changes in the crystalline lens and ciliary muscle during accommodation. METHODS: A total of 14 subjects were divided into two groups, young (aged between 20 and 25 years) and adult (aged between 35 and 40 years), and measured with an anterior segment optical coherence tomography. A semiautomatic procedure was implemented to measure the central lens thickness (CLT), anterior lens radius (ALR) and the ciliary muscle area (CMA) for the unaccommodated eye and for a vergence of - 3.00 D. RESULTS: The CLT increase for each population group was smaller than 5%, and the dispersion of each group was similar between them. Contrariwise, the reduction in the ALR was about 30% for both groups, although the young one showed the largest variability. The CMA increase was smaller than 30% for both groups, and the dispersion was similar between them. For each metric, differences between both groups were not statistically significant. CONCLUSIONS: The semiautomatic procedure seems to be useful for the in vivo analysis of the accommodative system. Additionally, the results obtained showed that changes in the CLT were much smaller compared to those obtained for the ALR or CMA.


Assuntos
Acomodação Ocular/fisiologia , Corpo Ciliar/anatomia & histologia , Diagnóstico por Computador/métodos , Cristalino/anatomia & histologia , Músculos Oculomotores/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Adulto , Feminino , Humanos , Masculino , Projetos Piloto , Refração Ocular/fisiologia , Adulto Jovem
2.
Arq Bras Oftalmol ; 80(6): 364-368, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29267571

RESUMO

PURPOSE: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. METHODS: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. RESULTS: Central corneal thickness was not altered at any stimulus vergence during accommodation (p>0.05). Conversely, anterior chamber depth was significantly reduced (p<0.05), whereas central lens thickness was significantly increased (p<0.05). Anterior segment length also increased with accommodation (p<0.05), indicating backward movement of the posterior pole. CONCLUSIONS: There are significant variations in anterior segment lengths that occur with accommodation. Studying these changes will provide useful information regarding the accommodation mechanism that can improve our understanding of this process and facilitate clinical decision-making by practitioners.


Assuntos
Acomodação Ocular/fisiologia , Segmento Anterior do Olho/anatomia & histologia , Segmento Anterior do Olho/diagnóstico por imagem , Tomografia de Coerência Óptica , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Arq. bras. oftalmol ; 80(6): 364-368, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888165

RESUMO

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any stimulus vergence during accommodation (p>0.05). Conversely, anterior chamber depth was significantly reduced (p<0.05), whereas central lens thickness was significantly increased (p<0.05). Anterior segment length also increased with accommodation (p<0.05), indicating backward movement of the posterior pole. Conclusions: There are significant variations in anterior segment lengths that occur with accommodation. Studying these changes will provide useful information regarding the accommodation mechanism that can improve our understanding of this process and facilitate clinical decision-making by practitioners.


RESUMO Objetivo: Avaliar as mudanças das estruturas anatômicas no segmento anterior do olho em termos de comprimentos axiais com acomodação por meio da tomografia de coerência óptica. Métodos: Neste estudo observacional, foram incluídos 25 olhos de vinte e cinco adultos saudáveis e medidos com o sistema Visante® omni tomografia de coerência óptica. A espessura corneana central, a profundidade da câmara anterior, a espessura central da lente e o comprimento do segmento anterior foram avaliados. Os parâmetros avaliados foram obtidos com acomodação usando diferentes vergências de estímulo: 0,0, -1,0, -2,0 e -3,0 D. A variação desses parâmetros foi comparada para os diferentes níveis de acomodação. Resultados: A espessura corneana central não foi alterada em nenhum estímulo durante a acomodação (p>0,05). A ACD mostrou uma redução significativa (p<0,05), enquanto a espessura central da lente foi significativamente aumentada (p<0,05). O comprimento do segmento anterior também aumentou com acomodação (p<0,05) indicando um movimento do polo posterior para trás. Conclusões: Há variações significativas nos comprimentos do segmento anterior que ocorrem com acomodação. Estudar essas mudanças fornece informações úteis sobre o mecanismo de acomodação para os profissionais, a fim de obter uma melhor compreensão desse processo e ajudá-los a tomar suas decisões clínicas.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Tomografia de Coerência Óptica , Acomodação Ocular/fisiologia , Segmento Anterior do Olho/anatomia & histologia , Segmento Anterior do Olho/diagnóstico por imagem
4.
Int J Ophthalmol ; 10(6): 955-960, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28730088

RESUMO

AIM: To investigate the potential effect that odd and even-order monochromatic aberrations may have on the accommodation response of the human eye. METHODS: Eight healthy subjects with astigmatism below 1 D, best corrected visual acuity 20/20 or better and normal findings in an ophthalmic examination were enrolled. An adaptive optics system was used in order to measure the accommodation response of the subjects' eyes under different conditions: with the natural aberrations being present, and with the odd and even-order aberrations being corrected. Three measurements of accommodation response were monocularly acquired at accommodation demands ranging from 0 to 4 D (0.5 D step). RESULTS: The accommodative lag was greater for the accommodative demands of 1.5, 3, 3.5 and 4 D for the condition in which the even-order aberrations were corrected, in comparison to that obtained for the natural aberrations and corrected odd-order aberrations for the same accommodation demands. No statistically significant differences were found between the accommodation responses under the three conditions. CONCLUSION: The odd and even-order aberrations are not helping the visual system to accommodate, because their partial correction do not affect the accommodation performance.

5.
Arq Bras Oftalmol ; 80(1): 9-13, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28380093

RESUMO

PURPOSE:: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. METHODS:: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation response were monocularly acquired at stimulus vergences ranging from 0 to 4 D (1-D step). RESULTS:: No statistically significant differences were found in the accommodation responses among the conditions. A moderate but gradually increasing root mean square, coma-like aberration was found for every condition. Conversely, the spherical aberration decreased as stimulus vergences increased. These outcomes were identified in comparison to the one-to-one ideal accommodation response, implying that a certain lag value was present in all stimulus vergences different from 0 D. CONCLUSIONS:: The results support the hypothesis that the difference between the ideal and real accommodation responses is mainly attributed to parameters associated with the accommodation process, such as the near visual acuity, depth of focus, pupil diameter, and wavefront aberrations. The wavefront aberrations were dependent on the 3-mm pupil size selected in this study. The accommoda tion response was not dependent on the electronic device employed in each condition, and it was mainly associated with young age and level of amplitude of accommodation of the subjects.


Assuntos
Acomodação Ocular/fisiologia , Telefone Celular , Computadores de Mão , Aberrações de Frente de Onda da Córnea/diagnóstico , Acuidade Visual/fisiologia , Aberrometria , Adulto , Humanos , Refração Ocular
6.
Arq. bras. oftalmol ; 80(1): 9-13, Jan.-Feb. 2017. graf
Artigo em Inglês | LILACS | ID: biblio-838777

RESUMO

ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation response were monocularly acquired at stimulus vergences ranging from 0 to 4 D (1-D step). Results: No statistically significant differences were found in the accommodation responses among the conditions. A moderate but gradually increasing root mean square, coma-like aberration was found for every condition. Conversely, the spherical aberration decreased as stimulus vergences increased. These outcomes were identified in comparison to the one-to-one ideal accommodation response, implying that a certain lag value was present in all stimulus vergences different from 0 D. Conclusions: The results support the hypothesis that the difference between the ideal and real accommodation responses is mainly attributed to parameters associated with the accommodation process, such as the near visual acuity, depth of focus, pupil diameter, and wavefront aberrations. The wavefront aberrations were dependent on the 3-mm pupil size selected in this study. The accommoda tion response was not dependent on the electronic device employed in each condition, and it was mainly associated with young age and level of amplitude of accommodation of the subjects.


RESUMO Objetivo: Avaliar a resposta de acomodação após períodos de leitura curtos usando um tablet e um smartphone, bem como para determinar potenciais diferenças na resposta de acomodação em estímulos de várias vergências com uma aberrômetro Hartmann-Shack. Método: Dezoito indivíduos saudáveis com astigmatismo inferior a 1 D, apresentando acuidade visual corrigida de 20/20 ou melhor com exame oftalmológico normal foram avaliados. As respostas acomodativas foram obtidas em três condições diferentes: sistema de acomodação com o olho relaxado, e visualmente estressado com um tablet e um smartphone por 10 min, a uma distância de 0,25 m dos olhos dos sujeitos. Três medidas de resposta acomodativa foram obtidas monocularmente com estímulos cujas vergências variaram de 0 a 4 D (intervalos de 1 D). Resultados: Não houve diferença estatisticamente significativa entre as respostas acomodativas em todas as condições. Foi observada moderada aberração do tipo coma com aumento progressivo para cada condição, enquanto houve diminuição da aberração esférica com o aumento das vergências do estímulo. Estes resultados foram identificados em comparação com a resposta acomodativa de um-para-um ideal, o que implica que um certo valor de desfasagem estava presente em todos os estímulos com vergências diferentes de 0 D. Conclusões: Os resultados apoiam a hipótese de que a diferença entre as respostas acomodativas ideal e real é atribuída principalmente a parâmetros tais como a acuidade visual para perto, profundidade de foco, diâmetro pupilar e aberrações de frente de onda, associados ao processo acomodativo. As aberrações de frente de onda foram dependentes do tamanho da pupila de 3 mm, selecionado neste estudo. A resposta acomodativa não foi dependente do dispositivo eletrônico empregue em cada condição e foi associada principalmente à idade jovem e ao nível da amplitude de acomodação dos sujeitos avaliados.


Assuntos
Humanos , Adulto , Acuidade Visual/fisiologia , Telefone Celular , Computadores de Mão , Aberrações de Frente de Onda da Córnea/diagnóstico , Acomodação Ocular/fisiologia , Refração Ocular , Aberrometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...