Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J La State Med Soc ; 161(5): 287-9, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19927944

RESUMO

This study compared the accuracy of a formula calculating cardiac output utilizing a patient size modification of a pulse pressure formula of Starr with that measured with a standard thermal dilution technique. During a six-month period 111 patients in the intensive care unit (ICU) on the cardiothoracic and vascular surgical services had comparison of their cardiac output by these two methods. The basic formula of Starr for stroke volume was converted to a stroke volume index by dividing by 1.7 and the empirically derived average body surface area in meters square. The stroke volume index was multiplied by the body surface area (BSA) of the patient to determine the patient's stroke volume in ml. Thus the modified stroke volume formula was 100-0.6 age-0.6 Diastolic Pressure + 0.5 Pulse Pressure x Patients BSA (m2)" over 1.7. Cardiac output was calculated by multiplying the stroke volume by heart rate. Nearly 60% of the patients had less than a 5% difference between the two methods, and over 90% had less than a 10% variance. In this particular population the highest variation was 18%. Thus, using only a carefully measured sphygmomanometer blood pressure, stroke volume and cardiac output can be determined with sufficient accuracy for clinical use.


Assuntos
Débito Cardíaco , Técnicas de Diluição do Indicador , Humanos , Esfigmomanômetros , Volume Sistólico , Termodiluição
2.
J Surg Res ; 134(1): 107-13, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16488437

RESUMO

BACKGROUND: Procedures that induce ischemic pre-conditioning during cardiac surgery will require a rapidly visualized hemodynamic monitor of acute ischemia. This study investigated the utility of a continuous loop tracing of left ventricular pressure (LVP) plotted against its derivative (dP/dt) as a visual beat-to-beat monitor of acute changes in myocardial relaxation due to global ischemia. MATERIALS AND METHODS: In 11 dogs, LVP, recorded via a micromanometer-tip catheter, was plotted against dP/dt as a continuous loop. The angle of the loop during relaxation is inversely related to tau, the time constant of isovolumic relaxation. The angle was measured before and during: infusion of dextran to increase pre-load, infusion of nitroprusside to reduce after-load, and a 30-s occlusion of the left main coronary artery to induce temporary global ischemia. RESULTS: The relaxation angle of the loop did not change with dextran or nitroprusside infusion. During left main occlusion, the angle increased from 57 +/- 7 degrees to 92 +/- 3 degrees (P < 0.001), reflecting markedly impaired relaxation. In five of nine cases, the angle became greater than 90 degrees, rendering the monoexponential model of pressure decay inapplicable. However, the beat-to-beat progression of the angle could easily be followed visually. CONCLUSIONS: The LVP-dP/dt loop is a readily visualized, continuous display of beat-to-beat changes in myocardial relaxation. It provides a dynamic and specific display of immediate changes in relaxation during global ischemia, even when the exponential model of pressure decay is not applicable. The loop may be useful for guiding procedures that induce ischemic pre-conditioning or post-conditioning during cardiac surgery.


Assuntos
Contração Miocárdica , Isquemia Miocárdica/fisiopatologia , Função Ventricular Esquerda , Animais , Diástole , Cães , Frequência Cardíaca , Monitorização Fisiológica
3.
Mol Genet Metab ; 82(1): 38-47, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15110320

RESUMO

Congenital adrenal hyperplasia (CAH) is a common inborn error of steroidogenesis. The clinical spectrum of CAH ranges from the severe classical form, which can be fatal in the newborn, to simple virilizing forms or a milder non-classical form which is often not diagnosed until puberty. Recessive mutations in the autosomal gene encoding 21-hydroxylase (CYP21) are responsible for approximately 95% of CAH cases. Since CYP21 genotype is generally predictive of the presence and severity of the disorder, accurate CYP21 genotyping is of clear medical significance. Determining the CYP21 genotype of an individual, using standard methods, is difficult due to the presence of a nearly identical pseudogene (CYP21P) in close proximity to the functional gene. To address the need for a comprehensive test for mutations in the CYP21 gene, we developed a multiplexed peptide mass signature genotyping (PMSG) assay and applied the assay to 151 DNA samples. CAH patients had been previously characterized for the 10 most common mutations. The PMSG assay detected all common mutations; in addition it identified six known rare mutations and also discovered four new mutations (two frameshifts in the first half of the gene, P42fs and S171fs, and two point mutations, H365Y and R479L). This assay has the potential to provide high-throughput, cost-effective analysis of the CYP21 gene to detect known mutations and identify novel variants in samples obtained from patients with CAH, individuals suspected to have CAH, and heterozygous carriers.


Assuntos
Hiperplasia Suprarrenal Congênita/genética , Mutação/genética , Peptídeos/química , Análise de Sequência de DNA/métodos , Esteroide 21-Hidroxilase/genética , Hiperplasia Suprarrenal Congênita/diagnóstico , Alelos , Análise Mutacional de DNA/métodos , Éxons/genética , Genótipo , Humanos , Recém-Nascido , Peptídeos/genética , Polimorfismo Genético/genética , Fases de Leitura/genética , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
4.
Artif Organs ; 20(5): 503-512, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-28868693

RESUMO

The Findlay centrifugal pump is unique in its two-stage pumping mechanisms and in its complementary interrelationship of the stages to each other and to the exit system, and it forms an extremely efficient unit. The first stage is a lift force pump as an inlet. The second and major stage is a shear force pump. Twenty-six prototypes, many multiply modified, have been hand fabricated, and most have had classic pump function analyses. Six pumps have demonstrated minimal hemolysis (3.5-5 h). At modest rotation speeds, it pumps water up to 10 L/min. Forty-four acute studies in normal dogs have been performed with the Findlay pump in a ventricular assist system. Blood flows through the pump ranged from 1.2 to 4.5 L/min. The conclusion is that the Findlay pump has the ability to operate with low blood damage, performs at acceptable rotational speed with reasonable hydraulic and mechanical efficiency, and is small and implantable.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...