Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 114(4): 517-23, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26213265

RESUMO

STATEMENT OF PROBLEM: Making implant impressions with different angulations requires a more precise and time-consuming impression technique. PURPOSE: The purpose of this in vitro study was to compare the accuracy of nonsplinted, splinted, and snap-fit impression techniques of internal connection implants with different angulations. MATERIAL AND METHODS: An experimental device was used to allow a clinical simulation of impression making by means of open and closed tray techniques. Three different impression techniques (nonsplinted, acrylic-resin splinted, and indirect snap-fit) for 6 internal-connected implants at different angulations (0, 15, 25 degrees) were examined using polyether. Impression accuracy was evaluated by measuring the differences in 3-dimensional (3D) position deviations between the implant body/impression coping before the impression procedure and the coping/laboratory analog positioned within the impression, using a coordinate measuring machine. Data were analyzed by 2-way ANOVA. Means were compared with the least significant difference criterion at P<.05. RESULTS: Results showed that at 25 degrees of implant angulation, the highest accuracy was obtained with the splinted technique (mean ±SE: 0.39 ±0.05 mm) and the lowest with the snap-fit technique (0.85 ±0.09 mm); at 15 degrees of angulation, there were no significant differences among splinted (0.22 ±0.04 mm) and nonsplinted technique (0.15 ±0.02 mm) and the lowest accuracy obtained with the snap-fit technique (0.95 ±0.15 mm); and no significant differences were found between nonsplinted and splinted technique at 0 degrees of implant placement. CONCLUSIONS: Splinted impression technique exhibited a higher accuracy than the other techniques studied when increased implant angulations at 25 degrees were involved.


Assuntos
Implantes Dentários , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica/instrumentação , Prótese Dentária Fixada por Implante , Técnica de Moldagem Odontológica/normas , Desenho de Equipamento , Humanos
2.
Int J Oral Maxillofac Implants ; 27(6): 1422-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23189292

RESUMO

PURPOSE: The purpose of this in vitro study was to investigate the effect of impression technique and implant angulation on the impression accuracy of external- and internal-connection implants using a novel experimental device. MATERIALS AND METHODS: An experimental device was designed and fabricated to make in vitro impressions by means of open- and closed-tray techniques. Impressions of eight implants with two different connections (four external-hex and four internal-hex) at three angulations (0, 15, and 25 degrees) were made using a medium-consistency polyether material. Evaluation of implant impression accuracy was carried out by directly measuring the difference in coordinate values between the implant body/impression coping positioned on the base and the impression coping/laboratory analog positioned in the impression using a touch-probe coordinate measuring machine. Experimental data were analyzed by two-way analysis of variance. The significance level of all hypothesis testing procedures was set at P<.05. RESULTS: The results showed that: (1) for implants with external connections, impression accuracy is not significantly affected by the impression technique, implant angulation, or their interaction; and (2) for implants with internal connections, impression accuracy is significantly affected only by implant angulation: Impression inaccuracy was greater at the 25-degree implant angulation. CONCLUSIONS: Within the limitations of this in vitro study, the open- and closed-tray techniques had no effect on the accuracy of multiple implant impressions. The interaction between impression technique and implant angulation was also not significant. However, implant angulation significantly affected the impression accuracy when implants with internal connections were used.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Análise de Variância , Projeto do Implante Dentário-Pivô/instrumentação , Projeto do Implante Dentário-Pivô/métodos , Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica/instrumentação , Técnica de Moldagem Odontológica/normas , Desenho de Equipamento , Modelos Dentários
3.
Comput Methods Programs Biomed ; 86(1): 30-8, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17267066

RESUMO

The paper presents computer-aided methods that allocate a dental implant and suggest its size, during the pre-operative planning stage, in conformance with introduced optimization criteria and established clinical requirements. Based on computed tomography data of the jaw and prosthesis anatomy, single tooth cases are planned for the best-suited implant insertion at a user-defined region. An optimum implantation axis line is produced and cylindrical implants of various candidate sizes are then automatically positioned, while their occlusal end is leveled to bone ridge, and evaluated. Radial safety margins are used for the assessment of the implant safety distance from neighboring anatomical structures and bone quantity and quality are estimated and taken into consideration. A case study demonstrates the concept and allows for its discussion.


Assuntos
Tomada de Decisões Assistida por Computador , Implantes Dentários , Dentística Operatória/organização & administração , Cuidados Pré-Operatórios , Grécia , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...