Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 197(2): 63-77, 2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34729602

RESUMO

The aim of the present study was to estimate the volume CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED) to patients from five multi-detector computed tomography angiography (MDCTA) procedures: brain, carotid, coronary, entire aorta and lower limb from four medical institutions in Tanzania; to compare these doses to those reported in the literature, and to compare the data obtained with ICRP 103 and Monte Carlo software. The radiation doses for 217 patients were estimated using patient demographics, patient-related exposure parameters, the geometry of examination and CT-Expo V 2.4 Monte Carlo-based software. The median values of the CTDIvol, DLP and ED for MDCTA procedures of the brain and carotids were 36.8 mGy, 1481.0 mGy∙cm and 5.2 mSv, and 15.9 mGy, 1224.0 mGy∙cm and 7.8 mSv, respectively; while for the coronary, entire aortic, and lower limbs were 49.4 mGy, 1493.0 mGy∙cm and 30.6 mSv; 16.2 mGy, 2287.0 mGy∙cm and 41.1 mSv; and 6.4 mGy, 1406.0 mGy∙cm and 10.5 mSv, respectively. The ratio of the maximum to minimum ED values to individual patients across the four medical centers were 41.4, 11.1, 4.6, 9.5 and 37.4, respectively, for the brain, carotid, coronary, entire aortic and lower limb CT angiography procedures. The mean values of CTDIvol, DLP and ED in the present study were typically higher than the values reported from Kenya, Korea and Saudi Arabia. The 75th percentile values of the DLP were above the preliminary diagnostic references levels proposed by Kenya, Switzerland and Korea. The observed wide range of examination scanning protocols and patient doses for similar MDCTA procedures within and across hospitals; and the observed relatively high patient doses compared to those reported in the literature, call for the need to standardize scanning protocols and optimise patient dose from MDCTA procedures.


Assuntos
Angiografia por Tomografia Computadorizada , Humanos , Quênia , Doses de Radiação , República da Coreia , Tanzânia
2.
Radiat Prot Dosimetry ; 181(4): 317-332, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29474654

RESUMO

Although contemporary cardiac X-ray exams are typically set so benefits outweighs the risk, the growing use and increasing complexity of the cardiovascular interventional radiological (CVIR) procedures does increase the risk of radiation-related tissue effects and stochastic effects to the individual patients and the population. In view of these radiological concerns there is a need to investigate factors that influence the doses received by the patients and enable optimisation needed. The air kerma area product (KAP), cumulative air kerma (CAK) and fluoroscopy time (FT) to patients from two major CVIR procedures: coronary angiography (CA) and percutaneous coronary interventions (PCI), were obtained from two major hospitals in Tanzania. The CAK and KAP were determined using ionisation chambers equipped in each angiographic unit. The median values of the KAP, CAK and FT for the CA procedures were 37.8 Gy cm2, 425.5 mGy and 7.6 min, respectively, while for the PCI were 86.5 Gy cm2, 1180.3 mGy and 19.0 min, respectively. The overall differences among individual KAP, CAK and FT values across the two hospitals investigated differed by factors of up to 33.5, 58.7 and 26.3 for the CA, while for the PCI procedures differed by factors of up to 10.9, 25.3 and 13.8, respectively. The mean values of KAP and FT for both CA and PCI were mostly higher than those reported values for Ireland, Belgium, Greece, France, China and Australia. The third quartiles of the KAP, CAK and FT for both CA and PCI were relatively above the preliminary diagnostic reference levels proposed by the IAEA, DIMOND III and SENTINEL. The observed substantial variations of mean values of technical parameters and patient doses (KAP, CAK and FT values) observed for the CA and PCI procedures inter and intra-hospitals were mainly explained by the complexity of the CVIR procedures, the nature of pathology, patient-specific characteristics, the variation in levels of skills and experiences among IC personnel, and the different procedural protocols employed among interventional cardiologists and hospitals. The observed great variations of procedural protocols and patient doses within and across the hospitals and relative higher dose than reported values from the literature call for the need to optimise radiation dose to patient from IC procedures.


Assuntos
Intervenção Coronária Percutânea , Doses de Radiação , Radiografia Intervencionista/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Tanzânia , Fatores de Tempo
3.
Radiat Prot Dosimetry ; 174(2): 262-274, 2017 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-27311734

RESUMO

The aim of this study was to investigate the nature and causes of radiation dose imparted to patients undergoing barium-based X-ray fluoroscopy procedures in Tanzania and to compare these doses to those reported in the literature from other regions worldwide. The air kerma area product (KAP) to patient undergoing barium investigations of gastrointestinal tract system was obtained from four consultant hospitals. The KAP was determined using a flat transparent transmission ionization chamber. Mean values of KAP for barium swallow (BS), barium meal (BM) and barium enema (BE) were 2.79, 2.62 and 15.04 Gy cm2, respectively. The mean values of KAP per hospital for the BS, BM and BE procedures varied by factors of up to 7.3, 1.6 and 2.0, respectively. The overall difference between individual patient doses across the four consultant hospitals investigated differed by factors of up to 53, 29.5 and 12 for the BS, BM and BE procedures, respectively. The majority of the mean values of KAP was lower than the reported values for Ghana, Greece, Spain and the UK, while slightly higher than those reported for India. The observed wide variation of KAP values for the same fluoroscopy procedure within and among the hospitals was largely attributed to the dynamic nature of the procedures, the patient characteristics, the skills and experience of personnel, and the different examination protocols employed among hospitals. The observed great variations of procedural protocols and patient doses within and across the hospitals call for the need to standardize examination protocols and optimize barium-based fluoroscopy procedures.


Assuntos
Bário , Fluoroscopia , Doses de Radiação , Gana , Grécia , Hospitais , Humanos , Índia , Exposição à Radiação , Espanha , Tanzânia
4.
Radiat Prot Dosimetry ; 173(1-3): 203-211, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27885088

RESUMO

The aim of this study was to assess the radiation burden imparted to patients from contrast-based X-ray fluoroscopy procedures in Tanzania. The effective doses (EDs) to patients from five contrast-based fluoroscopy procedures were obtained from four hospitals. The ED was estimated using the knowledge of the patient characteristics, patient-related exposure parameters, measurements of air kerma area product and PCXCM software. The median EDs for the barium swallow (BS), barium meal (BM), barium enema (BE), hysterosalpingography (HSG) and retrograde urethrography (RUG) were 0.50, 1.43, 2.83, 0.65 and 0.59 mSv, respectively. The median ED per hospital for the BS and BM procedures varied by factors of up to 9.9 and 4.2, respectively, while for the BE, HSG and RUG varied by factors of up to 2.3, 2.4 and 4.3, respectively. The overall differences between individual EDs across the four hospitals varied by factors of up to 53, 58.9 and 11.4 for the BS, BM and BE, respectively, while for the HSG and RUG differed by factors of up to 22 and 46.7, respectively. The mean EDs in this study were mostly lower than reported values from Spain, the UK, Ghana and Greece, while slightly higher than those reported from India. The observed wide variations of procedural protocols and patient doses within and across the hospitals; and the observed high patient doses in this study relative to those from the literature call for the need to standardize procedural protocols and optimize contrast-based fluoroscopy procedures.


Assuntos
Fluoroscopia , Doses de Radiação , Exposição à Radiação , Humanos , Inquéritos e Questionários , Tanzânia , Raios X
5.
J Appl Clin Med Phys ; 16(5): 435­441, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699324

RESUMO

The aim of this study was to evaluate the radiation doses to patient during chest and abdomen CR examinations, and assess the related level of optimization at five referral hospitals in Tanzania. The international code of practice for dosimetry in diagnostic radiology was applied to determine the entrance surface air kerma (ESAK) to patients. The level of optimization was assessed from low-contrast objects scores of phantom images at different exposures. The results show that mean ESAK varied from 0.16 to 0.37 mGy for chest PA and from 2 to 6 mGy for abdomen AP. Assuming similar patient and phantom attenuations, the optimization performed at all facilities was consistent with phantom evaluations in terms of tube potential settings in use. However, all facilities seemed to operate at higher tube load values above 5 mAs for chest examination, which can lead to unnecessary patient doses. Inadequate initial training on CR technology explains in large proportion the inappropriate use of exposure parameters.


Assuntos
Radiografia Abdominal/normas , Radiografia Torácica/normas , Encaminhamento e Consulta , Tomografia Computadorizada por Raios X/normas , Carga Corporal (Radioterapia) , Humanos , Doses de Radiação , Medição de Risco , Tanzânia
SELEÇÃO DE REFERÊNCIAS