Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Virol Methods ; 172(1-2): 78-80, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21172389

RESUMO

The Abbott RealTime HIV-1 assay is a real-time nucleic acid amplification assay available for HIV-1 viral load quantitation. The assay has a platform for automated extraction of viral RNA from plasma or dried blood spot samples, and an amplification platform with real time fluorescent detection. Overall, this study found no clinically relevant differences in viral load, if samples were extracted manually.


Assuntos
Infecções por HIV/virologia , HIV-1/fisiologia , Carga Viral/métodos , HIV-1/genética , HIV-1/isolamento & purificação , Humanos , RNA Viral/sangue , RNA Viral/genética , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Virol Methods ; 162(1-2): 218-22, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19729037

RESUMO

The performance of the Abbott m2000rt RealTime HIV-1 assay (RealTime HIV-1) with manual sample preparation was compared against the ROCHE COBAS AmpliPrep/AMPLICOR HIV-1 MONITOR Test v1.5 (CAP/CA HIV-1) using samples collected from 100 donors infected with HIV and 20 donors not infected with HIV in northern Tanzania where HIV-1 subtypes A, C, D, and their recombinant forms predominate. The RealTime HIV-1 appeared to have more within-run variability at high HIV-1 RNA concentrations, but total assay variability over the dynamic range tested was within the manufacturer's claim of <0.3 SD copies/mL. Accuracy studies showed 100% concordance for positive and negative values. When continuous values were examined, CAP/CA HIV-1 yielded higher values than the RealTime HIV-1 at higher nominal HIV-1 RNA concentrations. The RealTime HIV-1 assay showed excellent linearity between 2.5 and 7.0 log copies/mL. Of negative samples, 100% showed negative results, and >95% of samples with nominal concentrations of 40 copies/mL were detected at > or = 40 copies/mL by RealTime HIV-1. Manual sample preparation may contribute to higher total assay variability. This study suggests that the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation is an acceptable and feasible alternative to the conventional ROCHE COBAS AmpliPrep/AMLICOR HIV-1 Monitor v1.5 assay and that the RealTime HIV-1 assay performs well on samples from East Africa.


Assuntos
Infecções por HIV/diagnóstico , HIV-1 , Técnicas de Amplificação de Ácido Nucleico/métodos , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Doadores de Sangue , Genótipo , Infecções por HIV/virologia , HIV-1/classificação , HIV-1/genética , HIV-1/isolamento & purificação , HIV-1/fisiologia , Humanos , RNA Viral/sangue , Reprodutibilidade dos Testes , Tanzânia , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...