Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
2.
Sports Med ; 53(Suppl 1): 97-113, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37787844

RESUMO

A growing number of companies are developing or using wearable sensor technologies that can monitor, analyse and transmit data from humans in real time that can be used by the sporting, biomedical and media industries. To explore this phenomenon, we describe and review two high-profile sporting events where innovations in wearable technologies were trialled: the Tokyo 2020 Summer Olympic Games (Tokyo 2020, Japan) and the 2022 adidas Road to Records (Germany). These two major sporting events were the first time academic and industry partners came together to implement real-time wearable solutions during major competition, to protect the health of athletes competing in hot and humid environments, as well as to better understand how these metrics can be used moving forwards. Despite the undoubted benefits of such wearables, there are well-founded concerns regarding their use including: (1) limited evidence quantifying the potential beneficial effects of analysing specific parameters, (2) the quality of hardware and provided data, (3) information overload, (4) data security and (5) exaggerated marketing claims. Employment and sporting rules and regulations also need to evolve to facilitate the use of wearable devices. There is also the potential to obtain real-time data that will oblige medical personnel to make crucial decisions around whether their athletes should continue competing or withdraw for health reasons. To protect athletes, the urgent need is to overcome these ethical/data protection concerns and develop wearable technologies that are backed by quality science. The fields of sport and exercise science and medicine provide an excellent platform to understand the impact of wearable sensors on performance, wellness, health, and disease.


Assuntos
Esportes , Dispositivos Eletrônicos Vestíveis , Humanos , Atletas , Exercício Físico , Tecnologia
3.
Sports Med ; 53(6): 1255-1271, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36862339

RESUMO

BACKGROUND: Advanced footwear technology improves average running economy compared with racing flats in sub-elite athletes. However, not all athletes benefit as performance changes vary from a 10% drawback to a 14% improvement. The main beneficiaries from such technologies, world-class athletes, have only been analyzed using race times. OBJECTIVE: The aim of this study was to measure running economy on a laboratory treadmill in advanced footwear technology compared to a traditional racing flat in world-class Kenyan (mean half-marathon time: 59:30 min:s) versus European amateur runners. METHODS: Seven world-class Kenyan and seven amateur European male runners completed a maximal oxygen uptake assessment and submaximal steady-state running economy trials in three different models of advanced footwear technology and a racing flat. To confirm our results and better understand the overall effect of new technology in running shoes, we conducted a systematic search and meta-analysis. RESULTS: Laboratory results revealed large variability in both world-class Kenyan road runners, which ranged from a 11.3% drawback to a 11.4% benefit, and amateur Europeans, which ranged from a 9.7% benefit to a 1.1% drawback in running economy of advanced footwear technology compared to a flat. The post-hoc meta-analysis revealed an overall significant medium benefit of advanced footwear technology on running economy compared with traditional flats. CONCLUSIONS: Variability of advanced footwear technology performance appears in both world-class and amateur runners, suggesting further testing should examine such variability to ensure validity of results and explain the cause as a more personalized approach to shoe selection might be necessary for optimal benefit.


Assuntos
Corrida , Humanos , Masculino , Atletas , Fenômenos Biomecânicos , Quênia , Corrida de Maratona , Sapatos
4.
Sports Med Open ; 8(1): 82, 2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35727377

RESUMO

INTRODUCTION: Scientific and public interest in the potential ergogenic effects of sodium alginate added to a carbohydrate (CHO) beverage has increased in the last ~ 5 years. Despite an extensive use of this technology by elite athletes and recent research into the potential effects, there has been no meta-analysis to objectively elucidate the effects of adding sodium alginate to a CHO beverage on parameters relevant to exercise performance and to highlight gaps in the literature. METHODS: Three literature databases were systematically searched for studies investigating the effects of sodium alginate added to CHO beverage during prolonged, endurance exercise in healthy athletes. For the systematic review, the PROSPERO guidelines were followed, and risk assessment was made using the Cochrane collaboration's tool for assessing the risk of bias. Additionally, a random-effects meta-analysis model was used to determine the standardised mean difference between a CHO beverage containing sodium alginate and an isocaloric control for performance, whole-body CHO oxidation and blood glucose concentration. RESULTS: Ten studies were reviewed systematically, of which seven were included within the meta-analysis. For each variable, there was homogeneity between studies for performance (n = 5 studies; I2 = 0%), CHO oxidation (n = 7 studies; I2 = 0%) and blood glucose concentration (n = 7 studies; I2 = 0%). When compared with an isocaloric control, the meta-analysis demonstrated that there is no difference in performance (Z = 0.54, p = 0.59), CHO oxidation (Z = 0.34, p = 0.71) and blood glucose concentration (Z = 0.44, p = 0.66) when ingesting a CHO beverage containing sodium alginate. The systematic review revealed that several of the included studies did not use sufficient exercise intensity to elicit significant gastrointestinal disturbances or demonstrate any ergogenic benefit of CHO ingestion. Risk of bias was generally low across the included studies. CONCLUSIONS: This systematic review and meta-analysis demonstrate that the current literature indicates no benefit of adding sodium alginate to a CHO beverage during exercise. Further research is required, however, before firm conclusions are drawn considering the range of exercise intensities, feeding rates and the apparent lack of benefit of CHO reported in the current literature investigating sodium alginate.

5.
Artigo em Inglês | MEDLINE | ID: mdl-35162340

RESUMO

The introduction of carbon fiber plate shoes has triggered a plethora of world records in running, which has encouraged shoe industries to produce novel shoe designs to enhance running performance, including shoes containing conductor elements or "grounding shoes" (GS), which could potentially reduce the energy cost of running. The aim of this study was to examine the physiological and perceptual responses of athletes subjected to grounding shoes during running. Ten elite runners were recruited. Firstly, the athletes performed an incremental running test for VO2max and anaerobic threshold (AT) determination, and were familiarized with the two shoe conditions (traditional training shoe (TTS) and GS, the latter containing a conductor element under the insole). One week apart, athletes performed running economy tests (20 min run at 80% of the AT) on a 400 m dirt track, with shoe conditions randomized. VO2, heart rate, lactate, and perceived fatigue were registered throughout the experiment. No differences in any of the physiological or perceptual variables were identified between shoe conditions, with an equal running economy in both TTS and GS (51.1 ± 4.2 vs. 50.9 ± 5.1 mL kg-1 min-1, respectively). Our results suggest that a grounding stimulus does not improve the energy cost of running, or the physiological/perceptual responses of elite athletes.


Assuntos
Corrida , Sapatos , Atletas , Fenômenos Biomecânicos , Humanos , Ácido Láctico , Corrida/fisiologia
6.
J Strength Cond Res ; 36(4): 1162-1170, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32149877

RESUMO

ABSTRACT: Muniz-Pardos, B, Gomez-Bruton, A, Matute-Llorente, A, Gonzalez-Aguero, A, Gomez-Cabello, A, Gonzalo-Skok, O, Casajus, JA, and Vicente-Rodriguez, G. Nonspecific resistance training and swimming performance: Strength or power? A systematic review. J Strength Cond Res 36(4): 1162-1170, 2022-The purpose of this systematic review was to determine the type of nonspecific resistance intervention that is more effective to enhance swimming performance and to determine the nonspecific strength- or power-related variable that better predicts swimming performance. A search was conducted on PubMed, Cochrane Plus, and SportDiscus up to June 2018. Studies were distributed into 4 categories: dry-land strength (DLS), dry-land power (DLP), combination of training methods, and strength and power in start performance. From 1,844 citations, 33 met the inclusion criteria. Cross-sectional DLS studies showed positive associations between swimming performance and DLS development (especially through upper-body isometric assessments), although the efficacy of DLS training interventions remains unclear. Dry-land power training (principally through plyometrics) was a proficient, nonspecific method to enhance swimming block start performance (SBS; the start phase off the block and during the first 5-15 m), and jump assessment was the best predictor of SBS. Some pioneering nonspecific practices such as the acute exposure to high altitude or the maintenance of a high core temperature during the transition phase before competition seem to improve performance, although more research is required to confirm their efficacy. Further high-quality intervention studies are required to clarify the effect of DLP training on sprint swimming performance.


Assuntos
Desempenho Atlético , Treinamento Resistido , Estudos Transversais , Humanos , Força Muscular , Treinamento Resistido/métodos , Natação
7.
Nutrients ; 13(10)2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34684665

RESUMO

INTRODUCTION: Recent original research and meta-analyses suggest that acute caffeine supplementation improves exercise performance in team-sport athletes (TSA). Nonetheless, most of the studies testing the effects of caffeine on TSA included samples of male athletes, and there is no meta-analysis of the performance-enhancing effects of caffeine on female TSA. The aim of the present study was to synthesize the existing literature regarding the effect of caffeine supplementation on physical performance in adult female TSA. METHODS: A search was performed in Pubmed/Medline, SPORTDiscus and Scopus. The search was performed from the inception of indexing until 1 September 2021. Crossover randomized controlled trials (RCT) assessing the effects of oral caffeine intake on several aspects of performance in female TSA were selected. The methodological quality and risk of bias were assessed for individual studies using the Physiotherapy Evidence Database scale (PEDro) and the RoB 2 tool. A random-effects meta-analysis of standardized mean differences (SMD) was performed for several performance variables. RESULTS: The search retrieved 18 articles that fulfilled the inclusion/exclusion criteria. Overall, most of the studies were of excellent quality with a low risk of bias. The meta-analysis results showed that caffeine increased performance in specific team-sport skills (SMD: 0.384, 95% confidence interval (CI): 0.077-0.691), countermovement jump (SMD: 0.208, CI: 0.079-0.337), total body impacts (SMD: 0.488; 95% CI: 0.050, 0.927) and handgrip strength (SMD: 0.395, CI: 0.126-0.665). No effects were found on the ratings of perceived exertion, squat jumps, agility, repeated sprint ability or agility tests performed after fatigue. CONCLUSIONS: The results of the meta-analysis revealed that acute caffeine intake was effective in increasing some aspects of team-sports performance in women athletes. Hence, caffeine could be considered as a supplementation strategy for female athletes competing in team sports.


Assuntos
Atletas , Desempenho Atlético , Cafeína/farmacologia , Suplementos Nutricionais , Desempenho Físico Funcional , Feminino , Humanos
8.
Sports Med ; 51(11): 2237-2250, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34468950

RESUMO

Millions of consumer sport and fitness wearables (CSFWs) are used worldwide, and millions of datapoints are generated by each device. Moreover, these numbers are rapidly growing, and they contain a heterogeneity of devices, data types, and contexts for data collection. Companies and consumers would benefit from guiding standards on device quality and data formats. To address this growing need, we convened a virtual panel of industry and academic stakeholders, and this manuscript summarizes the outcomes of the discussion. Our objectives were to identify (1) key facilitators of and barriers to participation by CSFW manufacturers in guiding standards and (2) stakeholder priorities. The venues were the Yale Center for Biomedical Data Science Digital Health Monthly Seminar Series (62 participants) and the New England Chapter of the American College of Sports Medicine Annual Meeting (59 participants). In the discussion, stakeholders outlined both facilitators of (e.g., commercial return on investment in device quality, lucrative research partnerships, and transparent and multilevel evaluation of device quality) and barriers (e.g., competitive advantage conflict, lack of flexibility in previously developed devices) to participation in guiding standards. There was general agreement to adopt Keadle et al.'s standard pathway for testing devices (i.e., benchtop, laboratory, field-based, implementation) without consensus on the prioritization of these steps. Overall, there was enthusiasm not to add prescriptive or regulatory steps, but instead create a networking hub that connects companies to consumers and researchers for flexible guidance navigating the heterogeneity, multi-tiered development, dynamicity, and nebulousness of the CSFW field.


Assuntos
Medicina Esportiva , Esportes , Dispositivos Eletrônicos Vestíveis , Consenso , Exercício Físico , Humanos
9.
J Sports Med Phys Fitness ; 61(8): 1061-1072, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34256539

RESUMO

Rapid advances in wearable technologies and real-time monitoring have resulted in major inroads in the world of recreational and elite sport. One such innovation is the application of real-time monitoring, which comprises a smartwatch application and ecosystem, designed to collect, process and transmit a wide range of physiological, biomechanical, bioenergetic and environmental data using cloud-based services. We plan to assess the impact of this wireless technology during Tokyo 2020, where this technology could help characterize the physiological and thermal strain experienced by an athlete, as well as determine future management of athletes during a medical emergency as a result of a more timely and accurate diagnosis. Here we describe some of the innovative technologies developed for numerous sports at Tokyo 2020 ranging from race walking (20 km and 50 km events), marathon, triathlon, road cycling (including the time trial event), mountain biking, to potentially team sports played outdoors. A more symbiotic relationship between sport, health and technology needs to be encouraged that harnesses the unique demands of elite sport (e.g., the need for unobtrusive devices that provide real-time feedback) and serves as medical and preventive support for the athlete's care. The implementation of such applications would be particularly welcome in the field of medicine (i.e., telemedicine applications) and the workplace (with particular relevance to emergency services, the military and generally workers under extreme environmental conditions). Laboratory and field-based studies are required in simulated scenarios to validate such emerging technologies, with the field of sport serving as an excellent model to understand and impact disease.


Assuntos
Esportes , Telemedicina , Dispositivos Eletrônicos Vestíveis , Atletas , Ecossistema , Humanos
10.
J Sports Med Phys Fitness ; 61(8): 1173-1183, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34256541

RESUMO

The coronavirus disease (COVID-19) pandemic has had an unprecedent impact on the world of sport and society at large. Many of the challenges with respect to integrity previously facing competitive sport have been accentuated further during the pandemic. Threats to the integrity of sporting competition include traditional doping, issues of technological fairness, and integration of transgender and intersex athletes in elite sport. The enforced lull in competitive sport provides an unprecedented opportunity for stakeholders in sport to focus on unresolved integrity issues and develop and implement long-lasting solutions. There needs to be a concerted effort to focus on the many technological innovations accelerated by and perfected during COVID-19 that have enabled us to work from home, such as teaching students on-line, applications for medical advice, prescriptions and referrals, and treating patients in hospitals/care homes via video links and use these developments and innovations to enhance sport integrity and anti-doping procedures. Positive sports integrity actions will require a considered application of all such technology, as well as the inclusion of "omics" technology, big data, bioinformatics and machine learning/artificial intelligence approaches to modernize sport. Applications include protecting the health of athletes, considered non-discriminative integration of athletes into elite sport, intelligent remote testing to improve the frequency of anti-doping tests, detection windows, and the potential combination with omics technology to improve the tests' sensitivity and specificity in order to protect clean athletes and deter doping practices.


Assuntos
COVID-19 , Dopagem Esportivo , Inteligência Artificial , Atletas , Humanos , Pandemias , SARS-CoV-2
12.
BMJ Open Sport Exerc Med ; 7(2): e001041, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33927884

RESUMO

The Tokyo 2020 Olympic Games is expected to be among the hottest Games in modern history, increasing the chances for exertional heat stroke (EHS) incidence, especially in non-acclimatised athletes/workers/spectators. The urgent need to recognise EHS symptoms to protect all attendees' health has considerably accelerated research examining the most effective cooling strategies and the development of wearable cooling technology and real-time temperature monitoring. While these technological advances will aid the early identification of EHS cases, there are several potential ethical considerations for governing bodies and sports organisers. For example, the impact of recently developed cooling wearables on health and performance is unknown. Concerning improving athletic performance in a hot environment, there is uncertainty about this technology's availability to all athletes. Furthermore, the real potential to obtain real-time core temperature data will oblige medical teams to make crucial decisions around their athletes continuing their competitions or withdraw. Therefore, the aim of this review is (1) to summarise the practical applications of the most novel cooling strategies/technologies for both safety (of athletes, spectators and workers) and performance purposes, and (2) to inform of the opportunities offered by recent technological developments for the early recognition and diagnosis of EHS. These opportunities are presented alongside several ethical dilemmas that require sports governing bodies to react by regulating the validity of recent technologies and their availability to all.

13.
Children (Basel) ; 8(5)2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33926063

RESUMO

Most of the studies analyzing the effect of moderate to vigorous physical activity (MVPA) on children's health do not contain information on early stages or do not use accurate methods. We investigated the association between PA and body composition using objective methods, perinatal data, lifestyle behaviors, and World Health Organization (WHO) physical activity (PA) recommendations. The CALINA study is a longitudinal observational cohort study of children born in Aragon (Spain) in 2009. A total of 308 7-year-old children (52.3% boys) were assessed. We used dual-energy X-ray absorptiometry (DXA) and accelerometry. Rapid weight gain until 12 months and lifestyle behaviors were considered as covariates both in the ANCOVA and linear regression models. A higher percentage of boys met the WHO PA recommendations compared to girls (69.6% vs. 40.9%, respectively; p < 0.001). There was a negative association between MVPA and subtotal fat and abdominal fat in both girls and boys. After adjusting for perinatal and lifestyle variables, we found that subtotal body fat, abdominal fat, and fat mass index (FMI) were significantly lower in those classified as active. MVPA was associated with body fat both in boys and girls. More research is needed to identify the cutoffs points of MVPA that generate benefit to boys and girls in all body composition components.

15.
J Appl Physiol (1985) ; 130(5): 1421-1426, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33734832

RESUMO

The traditional method to measure 13CO2 enrichment in breath involves isotope ratio mass spectrometry (IRMS), which has several limitations such as cost, extensive training, and large space requirements. Here, we present the validity and reliability data of an isotope ratio infrared spectrometer (IRIS)-based method developed to combat these limitations. Eight healthy male runners performed 105 min of continuous running on a motorized treadmill while ingesting various carbohydrate beverages enriched with 13C and expired breath samples were obtained every 15 min in triplicates. A total of 213 breath samples were analyzed using both methods, whereas 212 samples were repeated using IRIS to determine test-retest reliability. Bland-Altman analysis was performed to determine systematic and proportional bias, and intraclass correlation coefficient (ICC) and coefficient of variation (CV) to assess level of agreement and magnitude of error. The IRIS method demonstrated a small but significant systematic bias to overestimate δ13CO2 (0.18‰; P < 0.05) compared with IRMS, without any proportional bias or heteroscedasticity and a small CV (0.5%). There was a small systematic bias during the test-retest of the IRIS method (-0.07‰; P < 0.05), no proportional bias, an excellent ICC (1.00), and small CV (0.4%). The use of the Delta Ray IRIS to determine 13C enrichment in expired breath samples captured during exercise has excellent validity and reliability when compared with the gold standard IRMS.NEW & NOTEWORTHY The use of IRIS to determine 13C enrichment in expired breath samples captured during exercise to determine exogenous glucose oxidation during exercise has excellent validity and reliability when compared with the gold standard IRMS.


Assuntos
Testes Respiratórios , Isótopos de Carbono , Humanos , Masculino , Espectrometria de Massas , Reprodutibilidade dos Testes , Espectrofotometria Infravermelho
16.
Sports Med Open ; 7(1): 19, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33721127

RESUMO

In an effort to reduce transmission and number of infections of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 or COVID-19) virus, governments and official bodies around the world have produced guidelines on the use of face masks and face coverings. While there is a growing body of recommendations for healthcare professionals and the wider population to use facial protection in "enclosed spaces" where minimal distancing from other individuals is not possible, there is a dearth of clear guidelines for individuals undertaking exercise and sporting activity. The present viewpoint aims to propose recommendations for face coverings while exercising during the COVID-19 pandemic that consider physical distancing, the environment, the density of active cases associated with the specific sports activity, and the practical use of face coverings in order to reduce potential viral transmission. Recommendations are provided on the basis of very limited available evidence in conjunction with the extensive collective clinical experience of the authors and acknowledging the need to consider the likelihood of the presence of the SARS-CoV-2 in the general population. We recommend that face coverings should be used in any environment considered to be of a high or moderate transmission risk, where tolerated and after individual risk assessment. In addition, as national caseloads fluctuate, individual sporting bodies should consider up to date guidance on the use of face coverings during sport and exercise, alongside other preventative measures.

17.
Sports Med ; 51(7): 1401-1415, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33761127

RESUMO

Sport is historically designated by the binary categorization of male and female that conflicts with modern society. Sport's governing bodies should consider reviewing rules determining the eligibility of athletes in the female category as there may be lasting advantages of previously high testosterone concentrations for transwomen athletes and currently high testosterone concentrations in differences in sex development (DSD) athletes. The use of serum testosterone concentrations to regulate the inclusion of such athletes into the elite female category is currently the objective biomarker that is supported by most available scientific literature, but it has limitations due to the lack of sports performance data before, during or after testosterone suppression. Innovative research studies are needed to identify other biomarkers of testosterone sensitivity/responsiveness, including molecular tools to determine the functional status of androgen receptors. The scientific community also needs to conduct longitudinal studies with specific control groups to generate the biological and sports performance data for individual sports to inform the fair inclusion or exclusion of these athletes. Eligibility of each athlete to a sport-specific policy needs to be based on peer-reviewed scientific evidence made available to policymakers from all scientific communities. However, even the most evidence-based regulations are unlikely to eliminate all differences in performance between cisgender women with and without DSD and transwomen athletes. Any remaining advantage held by transwomen or DSD women could be considered as part of the athlete's unique makeup.


Assuntos
Atletas , Desempenho Atlético , Consenso , Feminino , Humanos , Masculino , Desenvolvimento Sexual , Testosterona
18.
Sports Med ; 51(3): 371-378, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33442838

RESUMO

Every women's and men's world records from 5 km to the marathon has been broken since the introduction of carbon fibre plate (CFP) shoes in 2016. This step-wise increase in performance coincides with recent advancements in shoe technology that increase the elastic properties of the shoe thereby reducing the energy cost of running. The latest CFP shoes are acknowledged to increase running economy by more than 4%, corresponding to a greater than 2% improvement in performance/run time. The recently modified rules governing competition shoes for elite athletes, announced by World Athletics, that includes sole thickness must not exceed 40 mm and must not contain more than one rigid embedded plate, appear contrary to the true essence and credibility of sport as access to this performance-defining technology becomes the primary differentiator of sporting performance in elite athletes. This is a particular problem in sports such as athletics where the primary sponsor of the athlete is very often a footwear manufacturing company. The postponement of the 2020 Summer Olympics provides a unique opportunity for reflection by the world of sport and time to commission an independent review to evaluate the impact of technology on the integrity of sporting competition. A potential solution to solve this issue can involve the reduction of the stack height of a shoe to 20 mm. This simple and practical solution would prevent shoe technology from having too large an impact on the energy cost of running and, therefore, determining the performance outcome.


Assuntos
Corrida de Maratona , Corrida , Atletas , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Sapatos , Tecnologia
20.
Front Nutr ; 8: 810041, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35127792

RESUMO

PURPOSE: The purpose of this study is to quantify the effect of adding sodium alginate and pectin to a carbohydrate (CHO) beverage on exogenous glucose (ExGluc) oxidation rate compared with an isocaloric CHO beverage. METHODS: Following familiarization, eight well-trained endurance athletes performed four bouts of prolonged running (105 min; 71 ± 4% of VO2max) while ingesting 175 mL of one of the experimental beverages every 15 min. In randomized order, participants consumed either 70 g.h-1 of maltodextrin and fructose (10% CHO; NORM), 70 g.h-1 of maltodextrin, fructose, sodium alginate, and pectin (10% CHO; ENCAP), 180 g.h-1 of maltodextrin, fructose, sodium alginate, and pectin (26% CHO; HiENCAP), or water (WAT). All CHO beverages had a maltodextrin:fructose ratio of 1:0.7 and contained 1.5 g.L-1 of sodium chloride. Total substrate oxidation, ExGluc oxidation rate, blood glucose, blood lactate, serum non-esterified fatty acid (NEFA) concentration, and RPE were measured for every 15 min. Every 30 min participants provided information regarding their gastrointestinal discomfort (GID). RESULTS: There was no significant difference in peak ExGluc oxidation between NORM and ENCAP (0.63 ± 0.07 and 0.64 ± 0.11 g.min-1, respectively; p > 0.5), both of which were significantly lower than HiENCAP (1.13 ± 0.13 g.min-1, p < 0.01). Both NORM and HiENCAP demonstrated higher total CHO oxidation than WAT from 60 and 75 min, respectively, until the end of exercise, with no differences between CHO trials. During the first 60 min, blood glucose was significantly lower in WAT compared with NORM and HiENCAP, but no differences were found between CHO beverages. Both ENCAP and HiENCAP demonstrated a higher blood glucose concentration from 60-105 min than WAT, and ENCAP was significantly higher than HiENCAP. There were no significant differences in reported GID symptoms between the trials. CONCLUSIONS: At moderate ingestion rates (i.e., 70 g.h-1), the addition of sodium alginate and pectin did not influence the ExGluc oxidation rate compared with an isocaloric CHO beverage. At very high ingestion rates (i.e., 180 g.h-1), high rates of ExGluc oxidation were achieved in line with the literature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...