Med Phys ; 2018 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-29989176

RESUMO

PURPOSE: The purpose of this study was to evaluate the photon field effective energy (Eeff ) distribution and percentage depth-dose (PDD) within a mammography phantom by the analysis of the CaF2 :Tm (TLD-300) thermoluminescent (TL) glow curve. The experimental procedure involves the use of TLD-300 to determine with single dosimeter exposures both the relative dose and the beam quality. METHODS: TLD-300 chips were exposed to x rays from a GE Senographe 2000D mammography unit at the surface and different depths within a BR12 phantom. X-ray beams were generated with Mo/Mo, Mo/Rh, and Rh/Rh anode/filter combinations and voltages between 25 and 34 kV. Glow curves were deconvoluted into component peaks and the high- to low-temperature ratio (HLTR) was evaluated. The photon field Eeff was obtained from the HLTR values using a calibration curve determined previously. PDD was established from the peak 5 TL signal (TLSP5 ) at depths between 0.0 and 3.5 cm inside the phantom. Taking into account the differences in density and composition between CaF2 :Tm and breast tissue, an energy-dependent correction factor (ß(E)) was applied to TLSP5 . Measurements were compared with radiation transport Monte Carlo (MC) simulations performed with PENELOPE-2008. RESULTS: A typical 5% change in the HLTR from the phantom top surface to 3.5 cm depth was measured, which corresponds to a 2.2 keV increase in photon field Eeff . Values of the ß(E) correction factor were 0.33 and 0.13 for Eeff equal to 15.1 and 22.5 keV, respectively. This strong energy dependence of ß(E) is mostly due to the differences in fluence attenuation between CaF2 and breast tissue. According to PDD measurements, dose decreased to half the surface value at depths between 0.7 and 1.0 cm for Mo/Mo/25 and Rh/Rh/34 beams, respectively. Values of PDD, less than 10% at 3.5 cm depth, would have been overestimated by about 3.5% (a large relative error) if an energy-independent correction factor had been assumed. Mean differences between experiments and MC simulations were 0.8 keV and 1.2% in the determination of Eeff and PDD, respectively. CONCLUSION: The TLD-300 glow curve was used to accurately measure the photon field Eeff and PDD within a mammographic phantom. This work has demonstrated that Eeff and dose can be established simultaneously by using solely TLD-300.

3.
Phys Med Biol ; 60(6): 2135-44, 2015 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-25683355

RESUMO

We study the high- to low- temperature signal ratio (HLTR) of the CaF2:Tm glow curve as a function of beam quality for low-energy photon beams with effective energy between 15.2 and 33.6 keV, generated with W, Mo and Rh anodes. CaF2:Tm dosemeters (TLD-300) were exposed to x-rays and (60)Co gamma-rays. Glow curves were deconvoluted into 7 peaks, using computerized glow curve deconvolution and HLTR was evaluated. Air kerma and dose in water were between 2.1-15.0 mGy and 49.8-373.8 mGy, respectively. All peaks in the glow curve showed a linear response with respect to air kerma and dose in water. HLTR values decreased monotonically between 1.029 ± 0.010 (at 15.2 keV) and 0.821 ± 0.011 (33.6 keV), and no effects due to the use of different anode/filter combinations were observed. The results indicate a relatively high value of HLTR (about 1 for 17 keV effective energy, or 3 keV µm(-1) track-average LET) and a measurable dependence on the photon beam quality. Comparison of these photon data with HLTR for ions shows good quantitative agreement. The reported evolution of the CaF2:Tm glow curve could facilitate the estimation of the effective energy of unknown photon fields by this technique.


Assuntos
Fótons , Dosimetria Termoluminescente/métodos , Fluoreto de Cálcio/química , Raios gama , Doses de Radiação , Tálio/química , Dosimetria Termoluminescente/instrumentação , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...