Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
BMJ Open ; 14(2): e078264, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38341207

RESUMO

INTRODUCTION: The prevalence of gestational diabetes mellitus (GDM) is rising in the UK and is associated with maternal and neonatal complications. National Institute for Health and Care Excellence guidance advises first-line management with healthy eating and physical activity which is only moderately effective for achieving glycaemic targets. Approximately 30% of women require medication with metformin and/or insulin. There is currently no strong evidence base for any particular dietary regimen to improve outcomes in GDM. Intermittent low-energy diets (ILEDs) are associated with improved glycaemic control and reduced insulin resistance in type 2 diabetes and could be a viable option in the management of GDM. This study aims to test the safety, feasibility and acceptability of an ILED intervention among women with GDM compared with best National Health Service (NHS) care. METHOD AND ANALYSIS: We aim to recruit 48 women with GDM diagnosed between 24 and 30 weeks gestation from antenatal clinics at Wythenshawe and St Mary's hospitals, Manchester Foundation Trust, over 13 months starting in November 2022. Participants will be randomised (1:1) to ILED (2 low-energy diet days/week of 1000 kcal and 5 days/week of the best NHS care healthy diet and physical activity advice) or best NHS care 7 days/week until delivery of their baby. Primary outcomes include uptake and retention of participants to the trial and adherence to both dietary interventions. Safety outcomes will include birth weight, gestational age at delivery, neonatal hypoglycaemic episodes requiring intervention, neonatal hyperbilirubinaemia, admission to special care baby unit or neonatal intensive care unit, stillbirths, the percentage of women with hypoglycaemic episodes requiring third-party assistance, and significant maternal ketonaemia (defined as ≥1.0 mmol/L). Secondary outcomes will assess the fidelity of delivery of the interventions, and qualitative analysis of participant and healthcare professionals' experiences of the diet. Exploratory outcomes include the number of women requiring metformin and/or insulin. ETHICS AND DISSEMINATION: Ethical approval has been granted by the Cambridge East Research Ethics Committee (22/EE/0119). Findings will be disseminated via publication in peer-reviewed journals, conference presentations and shared with diabetes charitable bodies and organisations in the UK, such as Diabetes UK and the Association of British Clinical Diabetologists. TRIAL REGISTRATION NUMBER: NCT05344066.


Assuntos
Diabetes Mellitus Tipo 2 , Diabetes Gestacional , Metformina , Feminino , Humanos , Recém-Nascido , Gravidez , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Gestacional/diagnóstico , Dieta , Estudos de Viabilidade , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Metformina/uso terapêutico , Obesidade/tratamento farmacológico , Medicina Estatal , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
BMJ Open ; 13(7): e071395, 2023 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-37474169

RESUMO

INTRODUCTION: Rising levels of overweight and obesity among people with type 1 diabetes (T1D) contribute to insulin resistance, dyslipidaemia, retinopathy, cardiometabolic complications and psychological morbidity. Continuous low-energy diets (CLED) providing approximately 800 kcal (3347 kJ)/day can produce significant weight loss in type 2 diabetes, and intermittent low-energy diets (ILED) may be an alternative. The Manchester Intermittent and Daily diet Type 1 Diabetes App Study (MIDDAS-Type 1) aims to assess the safety, acceptability and feasibility of remotely delivered ILED and CLED programmes for people with T1D and overweight and obesity. METHODS AND ANALYSIS: Twelve participants with T1D and body mass index ≥27.5 kg/m2 (≥25 kg/m2 in high-risk ethnic minorities) recruited from an National Health Service (NHS) trust and research register in England will be randomised to a remotely delivered CLED (n=6) or ILED (n=6) for 12 weeks. The CLED includes a daily Optifast 850 kcal (3556 kJ) 75 g carbohydrate formula diet. The ILED includes 2 days/week of Optifast and 5 days of a portion-controlled Mediterranean diet (170-250 g carbohydrate/day). Both groups will receive matched high-frequency remote support from a dietitian, nurse and psychologist via telephone and/or the Oviva app. The primary outcome will assess safety (occurrence of severe hypoglycaemia, ketonaemia, ketoacidosis and time above and below target blood glucose). Secondary outcomes include study uptake, retention, dietary adherence, acceptability, intervention delivery fidelity and potential efficacy in relation to change in weight, insulin requirements, glycated haemoglobin, lipids, insulin resistance (estimated glucose disposal rate) and quality of life. Participants will be invited for optional repeat measurements at 52 weeks. ETHICS AND DISSEMINATION: The trial protocol (V4.0/08.06.2022) was granted ethical approval by Cambridge East Research Ethics Committee (Ref: 21/EE/0014). The study will inform progression to a full-scale randomised controlled trial to test the efficacy of these programmes for patients with T1D and overweight and obesity. TRIAL REGISTRATION NUMBER: NCT04674384; Pre-results.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Resistência à Insulina , Aplicativos Móveis , Humanos , Sobrepeso , Diabetes Mellitus Tipo 1/psicologia , Qualidade de Vida , Estudos de Viabilidade , Medicina Estatal , Obesidade , Dieta , Glicemia , Ensaios Clínicos Controlados Aleatórios como Assunto
6.
J Diabetes Sci Technol ; : 19322968221141924, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36475908

RESUMO

OBJECTIVE: Many hybrid closed-loop (HCL) systems struggle to manage unusually high glucose levels as experienced with intercurrent illness or pre-menstrually. Manual correction boluses may be needed, increasing hypoglycemia risk with overcorrection. The Cambridge HCL system includes a user-initiated algorithm intensification mode ("Boost"), activation of which increases automated insulin delivery by approximately 35%, while remaining glucose-responsive. In this analysis, we assessed the safety of "Boost" mode. METHODS: We retrospectively analyzed data from closed-loop studies involving young children (1-7 years, n = 24), children and adolescents (10-17 years, n = 19), adults (≥24 years, n = 13), and older adults (≥60 years, n = 20) with type 1 diabetes. Outcomes were calculated per participant for days with ≥30 minutes of "Boost" use versus days with no "Boost" use. Participants with <10 "Boost" days were excluded. The main outcome was time spent in hypoglycemia <70 and <54 mg/dL. RESULTS: Eight weeks of data for 76 participants were analyzed. There was no difference in time spent <70 and <54 mg/dL between "Boost" days and "non-Boost" days; mean difference: -0.10% (95% confidence interval [CI] -0.28 to 0.07; P = .249) time <70 mg/dL, and 0.03 (-0.04 to 0.09; P = .416) time < 54 mg/dL. Time in significant hyperglycemia >300 mg/dL was 1.39 percentage points (1.01 to 1.77; P < .001) higher on "Boost" days, with higher mean glucose and lower time in target range (P < .001). CONCLUSIONS: Use of an algorithm intensification mode in HCL therapy is safe across all age groups with type 1 diabetes. The higher time in hyperglycemia observed on "Boost" days suggests that users are more likely to use algorithm intensification on days with extreme hyperglycemic excursions.

7.
N Engl J Med ; 387(16): 1477-1487, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36198143

RESUMO

BACKGROUND: In persons with type 1 diabetes and high glycated hemoglobin levels, the benefits of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels are uncertain. METHODS: In a parallel-group, multicenter, randomized, controlled trial involving participants with type 1 diabetes and glycated hemoglobin levels between 7.5% and 11.0%, we investigated the efficacy of intermittently scanned continuous glucose monitoring as compared with participant monitoring of blood glucose levels with fingerstick testing. The primary outcome was the glycated hemoglobin level at 24 weeks, analyzed according to the intention-to-treat principle. Key secondary outcomes included sensor data, participant-reported outcome measures, and safety. RESULTS: A total of 156 participants were randomly assigned, in a 1:1 ratio, to undergo intermittently scanned continuous glucose monitoring (the intervention group, 78 participants) or to monitor their own blood glucose levels with fingerstick testing (the usual-care group, 78 participants). At baseline, the mean (±SD) age of the participants was 44±15 years, and the mean duration of diabetes was 21±13 years; 44% of the participants were women. The mean baseline glycated hemoglobin level was 8.7±0.9% in the intervention group and 8.5±0.8% in the usual-care group; these levels decreased to 7.9±0.8% and 8.3±0.9%, respectively, at 24 weeks (adjusted mean between-group difference, -0.5 percentage points; 95% confidence interval [CI], -0.7 to -0.3; P<0.001). The time per day that the glucose level was in the target range was 9.0 percentage points (95% CI, 4.7 to 13.3) higher or 130 minutes (95% CI, 68 to 192) longer in the intervention group than in the usual-care group, and the time spent in a hypoglycemic state (blood glucose level, <70 mg per deciliter [<3.9 mmol per liter]) was 3.0 percentage points (95% CI, 1.4 to 4.5) lower or 43 minutes (95% CI, 20 to 65) shorter in the intervention group. Two participants in the usual-care group had an episode of severe hypoglycemia, and 1 participant in the intervention group had a skin reaction to the sensor. CONCLUSIONS: Among participants with type 1 diabetes and high glycated hemoglobin levels, the use of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels resulted in significantly lower glycated hemoglobin levels than levels monitored by fingerstick testing. (Funded by Diabetes UK and others; FLASH-UK ClinicalTrials.gov number, NCT03815006.).


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem
8.
Lancet Healthy Longev ; 3(3): e135-e142, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35359882

RESUMO

Background: Older adults with type 1 diabetes have distinct characteristics that can make optimising glycaemic control challenging. We sought to test our hypothesis that hybrid closed-loop glucose control is safe and more effective than sensor-augmented pump (SAP) therapy in older adults with type 1 diabetes. Methods: In an open-label, multicentre, multinational (UK and Austria), randomised, crossover study, adults aged 60 years and older with type 1 diabetes using insulin pump therapy underwent two 16-week periods comparing hybrid closed-loop (CamAPS FX, CamDiab, Cambridge, UK) and SAP therapy in random order. Block randomisation by means of central randomisation software to one of two treatment sequences was stratified by centre. The primary endpoint was the proportion of time sensor glucose was in target range between 3·9 and 10·0 mmol/L. Analysis for the primary endpoint and adverse events was by intention-to-treat. The study has completed and is registered at ClinicalTrials.gov NCT04025762. Findings: 38 participants were enrolled. One participant withdrew during run-in because of difficulties with the study pump infusion sets. 37 participants (median [IQR] age 68 [63-70] years, mean [SD] baseline glycated haemoglobin [HbA1c]; 7·4% [0·9%]; 57 [10] mmol/mol) were randomly assigned between Sept 4, 2019, and Oct 2, 2020. The proportion of time with glucose between 3·9 and 10·0 mmol/L was significantly higher in the closed-loop group compared to the SAP group (79·9% [SD 7·9] vs 71·4% [13·2], difference 8·6 percentage points [95% CI 6·3 to 11·0]; p<0·0001). Two severe hypoglycaemia events occurred during the SAP period. There were two non-treatment related serious adverse events: cardiac arrest from pulmonary embolism associated with COVID-19 during the SAP period resulting in death, and a hospital presentation for parenteral hydrocortisone because of COVID-19 in a participant with adrenal insufficiency during the run-in period. Interpretation: Hybrid closed-loop insulin delivery is safe and achieves superior glycaemic control to SAP therapy in older adults with long duration of type 1 diabetes. Importantly this was achieved without increasing the risk of hypoglycaemia in this population with risk factors for severe hypoglycaemia. This suggests that hybrid closed-loop therapy is a clinically important treatment option for older adults with type 1 diabetes.


Assuntos
COVID-19 , Diabetes Mellitus Tipo 1 , Hipoglicemia , Idoso , Glicemia , Estudos Cross-Over , Glucose , Humanos , Hipoglicemiantes , Insulina , Sistemas de Infusão de Insulina , Pessoa de Meia-Idade , Resultado do Tratamento
10.
Acta Diabetol ; 58(2): 231-237, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33067723

RESUMO

AIMS: People with type 1 diabetes (T1D) face the daily task of implementing self-management strategies to achieve their glycaemic goals. The UK COVID-19 lockdown has had an impact on day-to-day behaviour, which may affect diabetes self-management and outcomes. We assessed whether sensor-based outcomes pre- and during lockdown periods were different in a cohort of glucose sensor users with T1D. METHODS: Data were collected from Freestyle Libre (FSL) or Dexcom G6 sensor users who remotely shared their data with the diabetes clinic web platform. Sensor metrics according to international consensus were analysed and compared between pre-lockdown period and 2 and 3 weeks into lockdown (periods 1 and 2). RESULTS: Two hundred and sixty-nine T1D patients (baseline HbA1c 57 ± 14 mmol/mol) were identified as FSL (n = 190) or Dexcom G6 (n = 79) users. In patients with sensor use > 70% (N = 223), compared to pre-lockdown period percentage TIR 3.9-10 mM (TIR) significantly increased during period 1 (59.6 ± 18.2 vs. 57.5 ± 17.2%, p = 0.002) and period 2 (59.3 ± 18.3 vs. 57.5 ± 17.2%, p = 0.035). The proportion of patients achieving TIR ≥ 70% increased from 23.3% pre-lockdown to 27.8% in period 1 and 30.5% in period 2. A higher proportion also achieved the recommended time below and above range, and coefficient of variation in periods 1 and 2. Dexcom G6 users had significantly lower % time below range (< 3.9 mM) compared to FSL users during both lockdown periods (period 1: Dexcom G6 vs. FSL: 1.8% vs. 4%; period 2: 1.4% vs. 4%, p < 0.005 for both periods). CONCLUSION: Sensor-based glycaemic outcomes in people with T1D in the current cohort improved during COVID-19 lockdown, which may be associated with positive changes in self-management strategies. Further work is required to evaluate long-term sustainability and support.


Assuntos
Glicemia/análise , COVID-19/epidemiologia , Diabetes Mellitus Tipo 1/sangue , Quarentena , Tecnologia de Sensoriamento Remoto/instrumentação , Telemedicina , Adulto , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Auditoria Clínica , Controle de Doenças Transmissíveis/métodos , Sistemas Computacionais , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Inglaterra/epidemiologia , Feminino , Acessibilidade aos Serviços de Saúde/organização & administração , Acessibilidade aos Serviços de Saúde/normas , Hospitais de Ensino , Humanos , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Pandemias , Tecnologia de Sensoriamento Remoto/normas , Estudos Retrospectivos , SARS-CoV-2/fisiologia , Telemedicina/instrumentação , Telemedicina/organização & administração , Telemedicina/normas
11.
Diabetes Care ; 43(10): 2537-2543, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32723843

RESUMO

OBJECTIVE: International type 1 diabetes registries have shown that HbA1c levels are highest in young people with type 1 diabetes; however, improving their glycemic control remains a challenge. We propose that use of the factory-calibrated Dexcom G6 CGM system would improve glycemic control in this cohort. RESEARCH DESIGN AND METHODS: We conducted a randomized crossover trial in young people with type 1 diabetes (16-24 years old) comparing the Dexcom G6 CGM system and self-monitoring of blood glucose (SMBG). Participants were assigned to the interventions in random order during two 8-week study periods. During SMBG, blinded continuous glucose monitoring (CGM) was worn by each participant for 10 days at the start, week 4, and week 7 of the control period. HbA1c measurements were drawn after enrollment and before and after each treatment period. The primary outcome was time in range 70-180 mg/dL. RESULTS: Time in range was significantly higher during CGM compared with control (35.7 ± 13.5% vs. 24.6 ± 9.3%; mean difference 11.1% [95% CI 7.0-15.2]; P < 0.001). CGM use reduced mean sensor glucose (219.7 ± 37.6 mg/dL vs. 251.9 ± 36.3 mg/dL; mean difference -32.2 mg/dL [95% CI -44.5 to -20.0]; P < 0.001) and time above range (61.7 ± 15.1% vs. 73.6 ± 10.4%; mean difference 11.9% [95% CI -16.4 to -7.4]; P < 0.001). HbA1c level was reduced by 0.76% (95% CI -1.1 to -0.4) (-8.5 mmol/mol [95% CI -12.4 to -4.6]; P < 0.001). Times spent below range (<70 mg/dL and <54 mg/dL) were low and comparable during both study periods. Sensor wear was 84% during the CGM period. CONCLUSIONS: CGM use in young people with type 1 diabetes improves time in target and HbA1c levels compared with SMBG.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Hemoglobinas Glicadas/metabolismo , Controle Glicêmico , Adolescente , Adulto , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/normas , Calibragem , Estudos de Coortes , Sistemas Computacionais/normas , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/etnologia , Feminino , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/efeitos dos fármacos , Controle Glicêmico/instrumentação , Controle Glicêmico/métodos , Controle Glicêmico/normas , Humanos , Insulina/administração & dosagem , Sistemas de Infusão de Insulina/normas , Masculino , Planejamento de Assistência ao Paciente , Fatores de Tempo , Reino Unido/epidemiologia , Adulto Jovem
12.
Br J Pain ; 14(1): 14-22, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32110394

RESUMO

BACKGROUND: Monitoring and improving the quality of care is an ever increasing concern for health care organisations. Measuring the effectiveness of clinical outcomes is done by looking at specific markers of high quality care. Pain management is considered one of the markers of high quality care and satisfaction with pain management is a crucial and important quality assurance marker; yet, we know little about what contributes to a patient's decision about satisfaction. METHODS: A qualitative study drawing on phenomenological approach aiming to evaluate the perspective of patients experiencing post-operative pain. Patients undergoing major abdominal surgery were recruited from a Renal Transplant and Urology ward in the North of England, UK. Data were collected using in-depth semi-structured interviews and were analysed using Colaizzi's approach. RESULTS: Ten patients participated in the study and three themes emerged from the analysis. The findings of this study revealed that in order to achieve satisfaction with the management of pain, patient care has to include information delivery which is timely and adequate according to a patient's individual needs, nurses should have a caring attitude and pain should be well controlled. CONCLUSION: Satisfaction with pain management is influenced by good communication and information transfer, appropriate pain management and an empathic presence throughout.

13.
Sci Rep ; 10(1): 3371, 2020 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-32099076

RESUMO

Neuropathic pain is believed to arise from damage to nociceptive C fibres in diabetic neuropathy (DN). We have utilised corneal confocal microscopy (CCM) to quantify the severity of small nerve fibre damage in relation to the severity of neuropathic pain and quality of life (QoL) in patients with and without painful DN. 30 controls and patients with painful (n = 78) and painless (n = 62) DN underwent assessment of large and small nerve fibre function, CCM, neuropathic symptoms (small fibre neuropathy symptom inventory questionnaire, neuropathic pain scale) and QoL (SF-36, pre-R-ODS and hospital anxiety and depression scale). Patients with painful compared to painless DN, had comparable neurophysiology and vibration perception, but lower corneal nerve fibre density (20.1 ± 0.87 vs. 24.13 ± 0.91, P = 0.005), branch density (44.4 ± 3.31 vs. 57.74 ± 3.98, P = 0.03), length (19.61 ± 0.81 vs. 22.77 ± 0.83, P = 0.01), inferior whorl length (18.03 ± 1.46 vs. 25.1 ± 1.95, P = 0.005) and cold sensation threshold (21.35 ± 0.99 vs. 26.08 ± 0.5, P < 0.0001) and higher warm sensation threshold (43.7 ± 0.49 vs. 41.37 ± 0.51, P = 0.004) indicative of small fibre damage. There was a significant association between all CCM parameters and the severity of painful neuropathic symptoms, depression score and QoL. CCM identifies small nerve fibre loss, which correlates with the severity of neuropathic symptoms and reduced QoL in patients with painful diabetic neuropathy.


Assuntos
Córnea/patologia , Neuropatias Diabéticas/fisiopatologia , Fibras Nervosas/fisiologia , Idoso , Estudos de Casos e Controles , Depressão/patologia , Neuropatias Diabéticas/complicações , Feminino , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Neuralgia/etiologia , Neuralgia/patologia , Qualidade de Vida , Limiar Sensorial , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...