Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(3)2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33572751

RESUMO

The paper presents the measurement process and test results for six thin-walled plates with different dynamic characteristics caused by different defects of welded joints. The tests were carried out using non-destructive testing (NDT). The authors made an attempt to determine the validity of the use and degree of effectiveness of the tests based on laser vibrometry in detecting defects in welded joints. The tests of welded plates were carried out using displacement laser sensors and piezoelectric accelerometers, while the source of vibration extortion was a modal hammer. In the adopted measurement methodology, the application of accelerometers was to obtain the reference data, which allowed for comparison with the measurement data obtained from the laser vibrometer. The analysis of the obtained measurement data, in the fields of time and frequency, made it possible to verify the correctness of the data obtained by means of laser vibrometry and to determine the requirements which are necessary for the correct performance of NDT tests and in the future structural health monitoring (SHM) system of welded joints with the use of a laser vibrometer. The mathematical model developed in the MSC software Pastran-Nastran was also used in the work. The model was developed for the purpose of mutual verification of the measurement and calculation tests. At the present stage of work, it can be stated that the results obtained by laser vibrometry methods should be treated as a supplement to the research conducted with traditional piezoelectric accelerometers. In certain situations, they can be used as an alternative to accelerometers, due to the fact that laser sensors do not require direct contact with the examined object. Where the object under test may be in a strong electromagnetic field, optical sensors are better suited than contact sensors.

2.
Adv Exp Med Biol ; 1176: 71-80, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31098943

RESUMO

In this study we hypothesized that the alleviation of neurological symptoms long after internal carotid artery (ICA) stenting may be related to sustained improvement of cerebral perfusion. Thirty-four subjects (F/M; 15/19) with >70% stenosis of a single internal carotid artery and neurological symptoms, who underwent a carotid artery stenting procedure, were studied. Brain computed tomography perfusion (CTP) imaging was performed before and 3 years after ICA stenting. The following relative variables were compared: cerebral blood flow (rCBF), cerebral blood volume (rCBV), mean transit time (rMTT), time to peak (rTTP), and permeability surface area product (rPS). A survey also was conducted to compare the patients' clinical symptoms. Overall, we found that a trend toward rMTT decline was the only persisting change after ICA stenting. We then stratified the patients into the subgroups of <2%, 2-5%, and > 5% rMTT decline and found that those with a rMTT decline >2% reported a prominent reduction in subjective clinical symptoms such as headache, dizziness, tinnitus, blurred vision, transient blindness, a sense of gravity of the head, and pain in the eyeballs. We conclude that a shortened mean rMTT, likely reflecting improved cerebral microcirculation, underlies the improvement of neurological symptoms in patients with ICA stenosis.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas , Circulação Cerebrovascular , Stents , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Feminino , Humanos , Masculino , Stents/normas , Tempo , Tomografia Computadorizada por Raios X
3.
Pol J Radiol ; 80: 57-61, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25674196

RESUMO

BACKGROUND: The common access to imaging methods based on ionizing radiation requires also radiation protection. The knowledge of ionizing radiation exposure risks among the medical staff is essential for planning diagnostic procedures and therapy. Evaluation of the knowledge of radiation safety during diagnostic procedures among the medical staff. MATERIAL/METHODS: The study consisted of a questionnaire survey. The questionnaire consisted of seven closed-ended questions concerning the knowledge of the effects of exposure to ionizing radiation as well as questions related to responder's profession and work experience. The study group included a total of 150 individuals from four professional groups: nurses, doctors, medical technicians, support staff. The study was carried out in the three largest hospitals in Gdansk between July and October 2013. RESULTS: The highest rates of correct answers to questions related to the issue of radiation protection were provided by the staff of radiology facilities and emergency departments with 1-5 years of professional experience. The most vulnerable group in terms of the knowledge of these issues consisted of individuals working at surgical wards with 11-15 years of professional experience. CONCLUSIONS: Education in the field of radiological protection should be a subject of periodic training of medical personnel regardless of position and length of service.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...