Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Artif Organs ; 25(2): 136-40, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11908488

RESUMO

Peripheral cannulation for cardiopulmonary bypass (CPB) is of prime interest in minimally invasive open heart surgery. As CPB is initiated with percutaneous cannulae, venous drainage is impeded due to smaller vessel and cannula size. A new cannula was developed which can change shape in situ and therefore may improve venous drainage. An in vitro circuit was set-up with a penrose latex tubing placed between the preload reservoir and the cannula, encasing the cannula's inlet and simulating the vena cava. The preload (P) was stabilised at 2 and at 5 mmHg respectively. The maximum flow rate was determined for 4 conditions: passive venous drainage (PVD) and assisted venous drainage (AVD) using a centrifugal pump at the 2 preload settings. We compared the results of the prototype cannula to classical femoral venous cannulae: basket 28Fr, a thoracic 28Fr and a percutaneous 27Fr. Under PVD conditions and a CVP of 2 mmHg, the prototype cannula's flow rate outperformed the next best cannula by 14% (p=0.0002) and 13% under AVD conditions (p=0.0001). Under PVD conditions and a CVP of 5 mmHg, the prototype cannula outperformed the percutaneous cannula by 19% (p=0.0001) and 14% under AVD conditions (p=0.0002). The new cannula outperforms the classical percutaneous venous cannulae during all of the four conditions tested in vitro.


Assuntos
Ponte Cardiopulmonar/instrumentação , Cateterismo/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Ponte Cardiopulmonar/métodos , Desenho de Equipamento , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
2.
Swiss Surg ; 7(5): 209-12, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11678019

RESUMO

BACKGROUND: A device to perform sutureless end-to-side coronary artery anastomosis has been developed by means of stent technology (GraftConnector). The present study assesses the long-term quality of the GraftConnector anastomosis in a sheep model. METHODS: In 8 adult sheep, 40-55 kg in weight, through left anterior thoracotomy, the right internal mammary artery (RIMA) was prepared and connected to the left anterior descending artery (LAD) by means of GraftConnector, on beating heart, without using any stabilizer. Ticlopidine 250 mg/day for anticoagulation for 4 weeks and Aspirin 100 mg/day for 6 months were given. The animals were sacrificed after 6 months and histological examination of anastomoses was carried out after slicing with the connector in situ for morphological analysis. RESULTS: All animals survived at 6 months. All anastomoses were patent and mean luminal width at histology was 1.8 +/- 0.2 mm; mean myotomia hyperplasia thickness was 0.21 +/- 0.1 mm. CONCLUSIONS: Long-term results demonstrate that OPCABGs performed with GraftConnector had 100% patency rate. The mean anastomotic luminal width corresponds to mean LAD's adult sheep diameter. We may speculate that myotomia hyperplasia occurred as a result of local device oversizing.


Assuntos
Anastomose de Artéria Torácica Interna-Coronária/instrumentação , Animais , Vasos Coronários/patologia , Displasia Fibromuscular/patologia , Ovinos , Grau de Desobstrução Vascular/fisiologia , Cicatrização/fisiologia
3.
Ann Thorac Surg ; 72(3): S999-1003, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11565736

RESUMO

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.


Assuntos
Anastomose Cirúrgica/instrumentação , Anastomose de Artéria Torácica Interna-Coronária/instrumentação , Técnicas de Sutura , Animais , Angiografia Coronária , Vasos Coronários/patologia , Estudos de Viabilidade , Fluoroscopia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Ovinos , Stents , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...