Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mater Today Bio ; 17: 100451, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36444341

RESUMO

Cardiovascular surgery involves reconstruction of tissues that are under cyclical mechanical loading, and in constant contact with pulsatile blood flow. Durable biomaterials for such tissue reconstruction are scarce, as they need to be mechanically strong, hemocompatible, and resist structural deterioration from calcification. While homografts are ideal, they are scarce; xenografts are immunogenic and rendered inactive from glutaraldehyde fixation, causing them to calficy and structurally deteriorate over time; decellularized xenografts are devoid of cells, mechanically weak; and synthetic polymeric scaffolds are thrombogenic or too dense to enable host cell infiltration. In this work, we report the in vivo feasibility of a new polymer-decellularized matrix composite material (decellularized bovine pericardium-polycaprolactone: chitosan) fabricated by electrospinning, which is designed to be mechanically strong and achieve programmed host cell honing to integrate into the host. In a rodent and sheep model, this new material was found to be hemocompatible, and enabled host cell infiltration into the polymer and the decellularized matrix core underlying the polymer. Presence of M2 macrophages and several vascular cell types, with matrix remodeling in the vicinity of the cells was observed in the explanted tissues. In summary, the proposed composite material is a novel approach to create in-situ host integrating tissue substitutes, with better non-thrombogenicity, reduced infections and endocarditis, and potentially the ability to grow with the patient and remodeling into a native tissue structure.

2.
Physiol Rep ; 10(14): e15305, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35871778

RESUMO

Cardiac volume overload from mitral regurgitation (MR) is a trigger for left ventricular dilatation, remodeling, and ultimate failure. While the functional and structural adaptations to this overload are known, the adaptation of myocardial mechanical properties remains unknown. Using a rodent model of MR, in this study, we discern changes in the passive material properties of the intact and decellularized myocardium. Eighty Sprague-Dawley rats (350-400 g) were assigned to two groups: (1) MR (n = 40) and (2) control (n = 40). MR was induced in the beating heart by perforating the mitral leaflet with a 23G needle, and rats were terminated at 2, 10, 20, or 40 weeks (n = 10/time-point). Echocardiography was performed at baseline and termination, and explanted hearts were used for equibiaxial mechanical testing of the intact myocardium and after decellularization. Two weeks after inducing severe MR, the myocardium was more extensible compared to control, however, stiffness and extensibility of the extracellular matrix did not differ from control at this timepoint. By 20 weeks, the myocardium was stiffer with a higher elastic modulus of 1920 ± 246 kPa, and a parallel rise in extracellular matrix stiffness. Despite some matrix stiffening, it only contributed to 31% and 36% of the elastic modulus of the intact tissue in the circumferential and longitudinal directions. At 40 weeks, similar trends of increasing stiffness were observed, but the contribution of extracellular matrix remained relatively low. Chronic MR induces ventricular myocardial stiffening, which seems to be driven by the myocyte compartment of the muscle, and not the extracellular matrix.


Assuntos
Matriz Extracelular/fisiologia , Ventrículos do Coração/fisiopatologia , Insuficiência da Valva Mitral/complicações , Animais , Insuficiência da Valva Mitral/fisiopatologia , Ratos , Ratos Sprague-Dawley , Remodelação Ventricular/fisiologia
3.
Front Cardiovasc Med ; 9: 807255, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402573

RESUMO

Objective: To investigate the feasibility of a hybrid material in which decellularized pericardial extracellular matrix is functionalized with polymeric nanofibers, for use as a cardiovascular tissue substitute. Background: A cardiovascular tissue substitute, which is gradually resorbed and is replaced by host's native tissue, has several advantages. Especially in children and young adults, a resorbable material can be useful in accommodating growth, but also enable rapid endothelialization that is necessary to avoid thrombotic complications. In this study, we report a hybrid material, wherein decellularized pericardial matrix is functionalized with a layer of polymeric nanofibers, to achieve the mechanical strength for implantation in the cardiovascular system, but also have enhanced cell honing capacity. Methods: Pericardial sacs were decellularized with sodium deoxycholate, and polycaprolactone-chitosan fibers were electrospun onto the matrix. Tissue-polymer interaction was evaluated using spectroscopic methods, and the mechanical properties of the individual components and the hybrid material were quantified. In-vitro blood flow loop studies were conducted to assess hemocompatibility and cell culture methods were used to assess biocompatibility. Results: Encapsulation of the decellularized matrix with 70 µm thick matrix of polycaprolactone-chitosan nanofibers, was feasible and reproducible. Spectroscopy of the cross-section depicted new amide bond formation and C-O-C stretch at the interface. An average peel strength of 56.13 ± 11.87 mN/mm2 was measured, that is sufficient to withstand a high shear of 15 dynes/cm2 without delamination. Mechanical strength and extensibility ratio of the decellularized matrix alone were 18,000 ± 4,200 KPa and 0.18 ± 0.03% whereas that of the hybrid was higher at 20,000 ± 6,600 KPa and 0.35 ± 0.20%. Anisotropy index and stiffness of the biohybrid were increased as well. Neither thrombus formation, nor platelet adhesion or hemolysis was measured in the in-vitro blood flow loop studies. Cellular adhesion and survival were adequate in the material. Conclusion: Encapsulating a decellularized matrix with a polymeric nanofiber coating, has favorable attributes for use as a cardiovascular tissue substitute.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...