Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 31(4): 564-77, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-14689241

RESUMO

Due to the stochastic nature of radioactive decay, any measurement of radioactivity concentration requires spatial averaging. In pharmacokinetic analysis of time-activity curves (TAC), such averaging over heterogeneous tissues may introduce a systematic error (heterogeneity error) but may also improve the accuracy and precision of parameter estimation. In addition to spatial averaging (inevitable due to limited scanner resolution and intended in ROI analysis), interindividual averaging may theoretically be beneficial, too. The aim of this study was to investigate the effect of such averaging on the binding potential ( BP) calculated with Logan's non-invasive graphical analysis and the "simplified reference tissue method" (SRTM) proposed by Lammertsma and Hume, on the basis of simulated and measured positron emission tomography data [[(11)C] d- threo-methylphenidate (dMP) and [(11)C]raclopride (RAC) PET]. dMP was not quantified with SRTM since the low k(2) (washout rate constant from the first tissue compartment) introduced a high noise sensitivity. Even for considerably different shapes of TAC (dMP PET in parkinsonian patients and healthy controls, [(11)C]raclopride in patients with and without haloperidol medication) and a high variance in the rate constants (e.g. simulated standard deviation of K(1)=25%), the BP obtained from average TAC was close to the mean BP (error <5%). However, unfavourably distributed parameters, especially a correlated large variance in two or more parameters, may lead to larger errors. In Monte Carlo simulations, interindividual averaging before quantification reduced the variance from the SRTM (beyond a critical signal to noise ratio) and the bias in Logan's method. Interindividual averaging may further increase accuracy when there is an error term in the reference tissue assumption E= DV(2)- DV' ( DV(2) = distribution volume of the first tissue compartment, DV' = distribution volume of the reference tissue). This can be explained by the fact that the distribution volume ratio ( DVR= DV/DV') obtained from averaged TAC is an approximation for Sigma DV/Sigma DV' rather than for Sigma DVR/ n. We conclude that Logan's non-invasive method and SRTM are suitable for heterogeneous tissues and that discussion of group differences in PET studies generally should include qualitative and quantitative assessment of interindividually averaged TAC.


Assuntos
Corpo Estriado/diagnóstico por imagem , Corpo Estriado/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/metabolismo , Racloprida/farmacocinética , Simulação por Computador , Técnicas de Diagnóstico por Radioisótopos , Humanos , Aumento da Imagem , Cinética , Taxa de Depuração Metabólica , Modelos Biológicos , Modelos Estatísticos , Ligação Proteica , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...