Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 50(12): 7525-7538, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37843980

RESUMO

BACKGROUND: Owing to its portability, affordability, and energy-efficiency, LED-based photoacoustic (PA) imaging is increasingly becoming popular when compared to its laser-based alternative, mainly for superficial vascular imaging applications. However, this technique suffers from low SNR and thereby limited imaging depth. As a result, visual image quality of LED-based PA imaging is not optimal, especially in sub-surface vascular imaging applications. PURPOSE: Combination of linear ultrasound (US) probes and LED arrays are the most common implementation in LED-based PA imaging, which is currently being explored for different clinical imaging applications. Traditional delay-and-sum (DAS) is the most common beamforming algorithm in linear array-based PA detection. Side-lobes and reconstruction-related artifacts make the DAS performance unsatisfactory and poor for a clinical-implementation. In this work, we explored a new weighting-based image processing technique for LED-based PAs to yield improved image quality when compared to the traditional methods. METHODS: We are proposing a lag-coherence factor (LCF), which is fundamentally based on the combination of the spatial auto-correlation of the detected PA signals. In LCF, the numerator contains lag-delay-multiply-and-sum (DMAS) beamformer instead of a conventional DAS beamformer. A spatial auto-correlation operation is performed between the detected US array signals before using DMAS beamformer. We evaluated the new method on both tissue-mimicking phantom (2D) and human volunteer imaging (3D) data acquired using a commercial LED-based PA imaging system. RESULTS: Our novel correlation-based weighting technique showed LED-based PA image quality improvement when it is combined with conventional DAS beamformer. Both phantom and human volunteer imaging results gave a direct confirmation that by introducing LCF, image quality was improved and this method could reduce side-lobes and artifacts when compared to the DAS and coherence-factor (CF) approaches. Signal-to-noise ratio, generalized contrast-to-noise ratio, contrast ratio and spatial resolution were evaluated and compared with conventional beamformers to assess the reconstruction performance in a quantitative way. Results show that our approach offered image quality enhancement with an average signal-to-noise ratio and spatial resolution improvement of around 20% and 25% respectively, when compared with conventional CF based DAS algorithm. CONCLUSIONS: Our results demonstrate that the proposed LCF based algorithm performs better than the conventional DAS and CF algorithms by improving signal-to-noise ratio and spatial resolution. Therefore, our new weighting technique could be a promising tool to improve the performance of LED-based PA imaging and thus accelerate its clinical translation.


Assuntos
Técnicas Fotoacústicas , Humanos , Técnicas Fotoacústicas/métodos , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Aumento da Imagem/métodos , Razão Sinal-Ruído , Ultrassonografia/métodos , Imagens de Fantasmas , Algoritmos
2.
J Opt Soc Am A Opt Image Sci Vis ; 39(10): 1805-1814, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36215552

RESUMO

Although a delay-and-sum (DAS) beamformer is best suited for real-time photoacoustic (PA) image formation, the reconstructed images are often afflicted by noises, sidelobes, and other intense artifacts due to inaccurate assumptions in PA signal correlation. The present work aims to develop a reconstruction method that reduces the occurrence of sidelobes and artifacts and thus improves the reconstructed image quality or imaging performance. This beamformer is fundamentally based on higher-order signal correlation wherein a higher number of delayed PA signals-compared to conventional delay-multiply-and-sum (DMAS)-are combined and summed up. The proposed technique provides significant improvements in resolution, contrast, and signal-to-noise ratio (SNR) compared to traditional beamformers. For real-time implementation, the proposed algorithms were simplified, and their computational complexities were shrunk to the order of DAS [O(N)]. A GPU based study was also performed to validate the real-time capability of the proposed beamformers. For validation studies, both numerical simulation and experiments were conducted. Quantitative evaluation studies involving SNR, contrast ratio, generalized contrast-to-noise ratio, and FWHM demonstrate that the proposed higher-order DMAS beamformer is superior in PA image reconstruction. Conclusively, the proposed beamformer uniquely facilitates real-time PA image reconstruction with an achievable frame rate close to DAS and DMAS but with better imaging performance, which holds promise for real-time PA imaging and its clinical applications.


Assuntos
Processamento de Imagem Assistida por Computador , Técnicas Fotoacústicas , Ácido 4-Acetamido-4'-isotiocianatostilbeno-2,2'-dissulfônico/análogos & derivados , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Técnicas Fotoacústicas/métodos , Razão Sinal-Ruído , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...