Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 131(2): 021802, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37505961

RESUMO

This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely ^{235}U-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. The reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5-7 MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.0 and 3.7 standard deviations the hypotheses that antineutrinos from ^{235}U are solely responsible and noncontributors to the excess observed at commercial reactors, respectively.

2.
Phys Rev C ; 1012020.
Artigo em Inglês | MEDLINE | ID: mdl-33336123

RESUMO

Reactor neutrino experiments have seen major improvements in precision in recent years. With the experimental uncertainties becoming lower than those from theory, carefully considering all sources of ν ¯ e is important when making theoretical predictions. One source of ν ¯ e that is often neglected arises from the irradiation of the nonfuel materials in reactors. The ν ¯ e rates and energies from these sources vary widely based on the reactor type, configuration, and sampling stage during the reactor cycle and have to be carefully considered for each experiment independently. In this article, we present a formalism for selecting the possible ν ¯ e sources arising from the neutron captures on reactor and target materials. We apply this formalism to the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, the ν ¯ e source for the the Precision Reactor Oscillation and Spectrum Measurement (PROSPECT) experiment. Overall, we observe that the nonfuel ν ¯ e contributions from HFIR to PROSPECT amount to 1% above the inverse beta decay threshold with a maximum contribution of 9% in the 1.8-2.0 MeV range. Nonfuel contributions can be particularly high for research reactors like HFIR because of the choice of structural and reflector material in addition to the intentional irradiation of target material for isotope production. We show that typical commercial pressurized water reactors fueled with low-enriched uranium will have significantly smaller nonfuel ν ¯ e contribution.

3.
Artigo em Inglês | MEDLINE | ID: mdl-33093736

RESUMO

Neutral particle detection in high-background environments is greatly aided by the ability to easily load 6Li into liquid scintillators. We describe a readily available and inexpensive liquid scintillation cocktail stably loaded with a Li mass fraction up to 1 %. Compositions that give thermodynamically stable microemulsions (reverse-micellar systems) were explored, using a Compton spectrum quenching technique to distinguish these from unstable emulsions. Scintillation light yield and transmittance were characterized. Pulse shape discrimination (PSD) was measured using a 252Cf source, showing that electron-like and proton-like recoil events are well-resolved even for Li loading up to 1 %, providing a means of background suppression in neutron/neutrino detectors. While samples in this work were prepared with nat Li (7.59 % 6Li), the neutron capture peak was clearly visible in the PSD spectrum; this implies that while extremely high capture efficiency could be achieved with 6Li-enriched material, a very inexpensive neutron-sensitive detector can be prepared with nat Li.

4.
Phys Rev Lett ; 122(25): 251801, 2019 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-31347897

RESUMO

This Letter reports the first measurement of the ^{235}U ν[over ¯]_{e} energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9 m from the 85 MW_{th} highly enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678±304(stat) ν[over ¯]_{e}-induced inverse beta decays, the largest sample from HEU fission to date, 99% of which are attributed to ^{235}U. Despite broad agreement, comparison of the Huber ^{235}U model to the measured spectrum produces a χ^{2}/ndf=51.4/31, driven primarily by deviations in two localized energy regions. The measured ^{235}U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the ν[over ¯]_{e} energy region of 5-7 MeV.

5.
Phys Rev C ; 100(1)2019.
Artigo em Inglês | MEDLINE | ID: mdl-35005330

RESUMO

Neutron spin rotation is expected from quark-quark weak interactions in the standard model, which induce weak interactions among nucleons that violate parity. We present the results from an experiment searching for the effect of parity violation via the spin rotation of polarized neutrons in a liquid 4He medium. The value for the neutron spin rotation angle per unit length in 4He, d ϕ / d z = [ + 2.1 ± 8.3 (stat.) - 0.2 + 2.9 (sys.) ] × 10 - 7 rad/m, is consistent with zero. The result agrees with the best current theoretical estimates of the size of nucleon-nucleon weak amplitudes from other experiments and with the expectations from recent theoretical approaches to weak nucleon-nucleon interactions. In this paper we review the theoretical status of parity violation in the n → + 4He system and discuss details of the data analysis leading to the quoted result. Analysis tools are presented that quantify systematic uncertainties in this measurement and that are expected to be essential for future measurements.

6.
Artigo em Inglês | MEDLINE | ID: mdl-30983652

RESUMO

Liquid scintillation cocktails loaded with neutron capture agents such as 6Li are used in both neutron and neutrino detectors. For detectors designed to operate over extended timespans, long-term stability can be a concern. We demonstrate the identification of thermodynamically unstable emulsions as distinct from stable microemulsions, driving phase separation with centrifugation. Phase separation was identified by monitoring the quench indicating parameter, measured using an external Compton source. Samples were also characterized by dynamic light scattering, where in an extreme case, phase separation could be observed in real time. We describe a stable cocktail with 0.01 mass fraction added Li, a relatively high Li concentration.

7.
Phys Rev Lett ; 116(24): 242501, 2016 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-27367385

RESUMO

The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the ß decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782 keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335±0.00005[stat]±0.00015[syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14 keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582±0.00023[stat]±0.00062[syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.

8.
Rev Sci Instrum ; 87(2): 021301, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931826

RESUMO

We present the development of the miniTimeCube (mTC), a novel compact neutrino detector. The mTC is a multipurpose detector, aiming to detect not only neutrinos but also fast/thermal neutrons. Potential applications include the counterproliferation of nuclear materials and the investigation of antineutrino short-baseline effects. The mTC is a plastic 0.2% (10)B-doped scintillator (13 cm)(3) cube surrounded by 24 Micro-Channel Plate (MCP) photon detectors, each with an 8 × 8 anode totaling 1536 individual channels/pixels viewing the scintillator. It uses custom-made electronics modules which mount on top of the MCPs, making our detector compact and able to both distinguish different types of events and reject noise in real time. The detector is currently deployed and being tested at the National Institute of Standards and Technology Center for Neutron Research nuclear reactor (20 MWth) in Gaithersburg MD. A shield for further tests is being constructed, and calibration and upgrades are ongoing. The mTC's improved spatiotemporal resolution will allow for determination of incident particle directions beyond previous capabilities.

9.
Rev Sci Instrum ; 86(5): 055101, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26026552

RESUMO

We present the design, description, calibration procedure, and an analysis of systematic effects for an apparatus designed to measure the rotation of the plane of polarization of a transversely polarized slow neutron beam as it passes through unpolarized matter. This device is the neutron optical equivalent of a crossed polarizer/analyzer pair familiar from light optics. This apparatus has been used to search for parity violation in the interaction of polarized slow neutrons in matter. Given the brightness of existing slow neutron sources, this apparatus is capable of measuring a neutron rotary power of dϕ/dz = 1 × 10(-7) rad/m.

10.
Phys Rev Lett ; 107(10): 102301, 2011 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-21981496

RESUMO

We report the results of an improved determination of the triple correlation DP·(p(e)×p(v)) that can be used to limit possible time-reversal invariance in the beta decay of polarized neutrons and constrain extensions to the standard model. Our result is D=[-0.96±1.89(stat)±1.01(sys)]×10(-4). The corresponding phase between gA and gV is ϕAV=180.013°±0.028° (68% confidence level). This result represents the most sensitive measurement of D in nuclear ß decay.

11.
Rev Sci Instrum ; 79(3): 031301, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18376990

RESUMO

We describe the design, construction, and performance of three generations of superconducting Ioffe magnetic traps. The first two are low current traps, built from four racetrack shaped quadrupole coils and two solenoid assemblies. Coils are wet wound with multifilament NbTi superconducting wires embedded in epoxy matrices. The magnet bore diameters are 51 and 105 mm with identical trap depths of 1.0 T at their operating currents and at 4.2 K. A third trap uses a high current accelerator-type quadrupole magnet and two low current solenoids. This trap has a bore diameter of 140 mm and tested trap depth of 2.8 T. Both low current traps show signs of excessive training. The high current hybrid trap, on the other hand, exhibits good training behavior and is amenable to quench protection.

12.
J Res Natl Inst Stand Technol ; 110(3): 205-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308122

RESUMO

In the meson exchange model of weak nucleon-nucleon (NN) interactions, the exchange of virtual mesons between the nucleons is parameterized by a set of weak meson exchange amplitudes. The strengths of these amplitudes from theoretical calculations are not well known, and experimental measurements of parity-violating (PV) observables in different nuclear systems have not constrained their values. Transversely polarized cold neutrons traveling through liquid helium experience a PV spin rotation due to the weak interaction with an angle proportional to a linear combination of these weak meson exchange amplitudes. A measurement of the PV neutron spin rotation in helium (φ PV ( n ,α)) would provide information about the relative strengths of the weak meson exchange amplitudes, and with the longitudinal analyzing power measurement in the p + α system, allow the first comparison between isospin mirror systems in weak NN interaction. An earlier experiment performed at NIST obtained a result consistent with zero: φ PV ( n ,α) = (8.0 ±14(stat) ±2.2(syst)) ×10(-7) rad / m[1]. We describe a modified apparatus using a superfluid helium target to increase statistics and reduce systematic effects in an effort to reach a sensitivity goal of 10(-7) rad/m.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...