Australas Phys Eng Sci Med ; 18(4): 185-96, 1995 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8867389

RESUMO

The three-detector TRIAD 88 is a variable cylindrical FOV whole-body SPECT system designed for both brain as well as body organ imaging. The system performance was assessed in terms of physical indices and clinical quality. Measures of low contrast resolution using contrast-detail curves, high contrast resolution using LSFs and associated frequency descriptors, display characteristics, system sensitivity, energy resolution and uniformity analysis were utilized. In addition, images of Carlson phantom, Hoffman brain phantom and clinical brain images were used to compare two collimators subjectively. Measurements and calculations were obtained for two sets of parallel hole collimators, i.e., LEUR_PAR and LEHR_PAR. Of special interest is the consistency among the three detectors. The planar and volume sensitivities for the LEUR_PAR collimator were about 58% of those of the LEHR_PAR collimator. The planar spatial resolution of the two collimators differed by about 14%. The display was characterized by a logistic model H & D curve. The planar contrast-detail curves demonstrated no statistical difference in lesion detectability between the two collimator types, however SPECT phantom and clinical images demonstrated improved performance with the LEUR_PAR collimator. Images of Hoffman single slice brain and Carlson phantoms and Tc-99m (HMPAO) brain images demonstrated excellent image quality. There was similarity in performance parameters of the three detector heads.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Fenômenos Biofísicos , Biofísica , Encéfalo/diagnóstico por imagem , Estudos de Avaliação como Assunto , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
Med Phys ; 15(2): 211-4, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3386591

RESUMO

A full radioscintigraphic monitor/film system sensitometric curve has been obtained utilizing a bootstrap technique in which individual characteristic curve segments, obtained from stepwedge-graded exposures, are tied together at the point of overlap. Curve segments were first smoothed by employing the linearized form of the logistic distribution function. This function allows calculation of gradient-exposure and gradient-density relations for the full characteristic curve.


Assuntos
Modelos Teóricos , Radiometria/métodos , Humanos , Matemática