1.
J Oral Sci ; 64(4): 274-278, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36070925

RESUMO

PURPOSE: This study investigates the attenuation of radiation doses by four materials, heat-polymerized, and self-polymerized polymethyl methacrylate (PMMA), putty-type, and injection-type polyvinyl siloxane (PVS) impression material. This in vitro study should aid in the selection of dental materials for radiotherapy prostheses, thereby minimizing the possibility of radiotherapy side effects. METHODS: Specimens of each type were fabricated as a 5 × 5 cm squares with a thickness of 10 mm. Heat-polymerizing PMMA, self-polymerizing PMMA, putty-type PVS impression material, and injection-type PVS impression material were selected. A calibration curve was created to determine the association of radiation doses and grayscale value. A linear accelerator was used to irradiate the specimens. The radiation doses above and below the materials were measured using radiochromic film dosimetry. After film irradiation, the pixel scale of color change was used to determine the radiation dose based on the created calibration curve. The results were exported to find average doses to calculate the percentage of the attenuated dose for a comparison of the four materials. RESULTS: The average attenuated doses of heat-polymerizing PMMA, self-polymerizing PMMA, putty-type PVS, and injection-type PVS were 10.8%, 6.2%, 17.2%, and 14.2% respectively. CONCLUSION: PVS showed higher attenuating radiation exposure compared with PMMA.


Assuntos
Implantes Dentários , Polimetil Metacrilato , Materiais para Moldagem Odontológica , Polivinil , Siloxanas
2.
J Contemp Brachytherapy ; 9(2): 151-157, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28533804

RESUMO

PURPOSE: To assess the feasibility of applying trans-applicator intracavitary ultrasonography to image-guided brachytherapy for cervical cancer. MATERIAL AND METHODS: For this experiment, a phantom was created and included a polyethylene tube, intended to simulate a tandem applicator, which was inserted into chicken meat and embedded in agar, along with magnetic resonance imaging (MRI)-compatible ovoid applicators. Three-dimensional images of the phantom were obtained using computed tomography (CT), MRI (T2-weighted), and intracavitary ultrasonography sectional images acquired at 1 mm slice intervals. Intracavitary ultrasonography images were acquired from within the simulated tandem applicator using a radial transducer. Magnetic resonance imaging and intracavitary ultrasonography images were manually registered onto CT images. The chicken meat was contoured as the target volume independently on the CT, MRI, and intracavitary ultrasonography images, and the Dice similarity coefficient was used to compare the target volumes. The dose distributions of a sample brachytherapy plan were also evaluated. RESULTS: Computed tomography, MRI, and intracavitary ultrasonography all visualized the three-dimensional phantom volumes. Intracavitary ultrasonography images depicted the meat with high echoic signals and a border clearly distinguishable from the surrounding agar. The Dice similarity coefficient values for the target volumes on CT vs. MRI, CT vs. intracavitary ultrasonography, and MRI vs. intracavitary ultrasonography were 0.966, 0.965, and 0.971, respectively, indicating similar contouring with the three modalities. Among the modalities, the differences in D50, D90, D98, and D100 values were 1.8%, 2.9%, 3.7%, and 2.9%, respectively. CONCLUSIONS: Three-dimensional reconstructed trans-applicator intracavitary ultrasonographic images clearly depicted meat tissue within the phantom, and could thus be used for brachytherapy planning. This study proves the concept of trans-applicator intracavitary ultrasonography for intracavitary brachytherapy. Further research such as development of intracavitary ultrasonography system, 3D reconstruction method, ultrasonography-compatible applicators, and ultrasonography-based target concept is warranted to assess the potential clinical application.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...