Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(24)2020 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-33348634

RESUMO

In this work, we compare first acquisitions from the ASI-PRISMA (Agenzia Spaziale Italiana-PRecursore IperSpettrale della Missione Applicativa) space mission with model simulations, past data acquired by the Hyperion sensor and field spectrometer measurements. The test site is 'Piano delle Concazze' (Mt. Etna, Italy), suitable for calibration purposes due to its homogeneity characteristics. The area measures at about 0.2 km2 and is composed of very homogeneous trachybasalt rich in plagioclase and olivine. Three PRISMA acquisitions, achieved on 31 July and 8 and 17 August 2019, are analyzed. Firstly, spectral profiles of PRISMA top of atmosphere (TOA) radiance are compared with MODerate resolution atmospheric TRANsmission (MODTRAN) simulations. The Pearson correlation coefficient is equal to 0.998 and 0.994 for VNIR (Visible and Near InfraRed) and SWIR (Short-Wave InfraRed) spectral ranges, respectively. PRISMA radiance overestimates values simulated by MODTRAN for all considered days, showing a mean bias of +5.22 and of +0.91 Wm-2sr-1µm-1 for VNIR and SWIR, respectively. The relative mean difference between reflectance values estimated by PRISMA and Hyperion, on the test area, is around +19%, despite the great difference in time acquisition (up to 19 years); PRISMA slightly overestimates Hyperion reflectance with an absolute mean difference of about +0.0083, within the variability of Hyperion acquisitions of ±0.0250 (corresponding to ±2 standard deviation). Finally, FieldSpec measurements also confirm the great quality of PRISMA reflectance estimations. The absolute mean difference results are around +0.0089 (corresponding to a relative error of about +21%). In the study, we investigate only the lower values of reflectance characterizing the test site. A more complete evaluation of PRISMA performances needs to consider other test sites with different optical characteristics.

2.
Sensors (Basel) ; 15(1): 194-213, 2014 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-25609042

RESUMO

The conservation of architectural heritage usually requires a multidisciplinary approach involving a variety of specialist expertise and techniques. Nevertheless, destructive techniques should be avoided, wherever possible, in order to preserve the integrity of the historical buildings, therefore the development of non-destructive and non-contact techniques is extremely important. In this framework, a methodology for combining the terrestrial laser scanning and the infrared thermal images is proposed, in order to obtain a reconnaissance of the conservation state of a historical building. The proposed case study is represented by St. Augustine Monumental Compound, located in the historical centre of the town of Cosenza (Calabria, South Italy). Adopting the proposed methodology, the paper illustrates the main results obtained for the building test overlaying and comparing the collected data with both techniques, in order to outline the capabilities both to detect the anomalies and to improve the knowledge on health state of the masonry building. The 3D model, also, allows to provide a reference model, laying the groundwork for implementation of a monitoring multisensor system based on the use of non-destructive techniques.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...