Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(19)2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37837028

RESUMO

Surveyors are occasionally tasked to with determining the coordinates of inaccessible locations or points in civil engineering applications, ground control points for photogrammetry or LiDAR data acquisition, among others. The present work outlines and investigates a novel method for estimating the GNSS coordinates of an inaccessible location where a surveying instrument cannot be set up. The procedure is based on the well-known surveying intersection method and data extracted from an Earth Gravity Model (e.g., EGM 2008). The location's coordinates are obtained from the least-squares adjustment of the angles and distances measured from at least two sites to the unknown point using a total station, within the framework of the Gauss-Helmert method. Field tests confirmed that the accuracy of the determined coordinates of the inaccessible point is at the level of 1 cm. The proposed method bypasses standard coordinate transformation steps performed with the traditional approach, directly producing geocentric coordinates of the unknown points.

2.
Sensors (Basel) ; 21(21)2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34770590

RESUMO

The correct estimation of earth pressure is important for the design of earth retaining structures and depends, among others, on the surface morphology of retaining structures. The diaphragm wall created as a protection of a deep excavation located in an urbanized area was selected as a research object. Terrestrial Laser Scanning (TLS) was used for the investigation of the unique surface (in real-world dimension) obtained by tremieying the concrete in different soil layers. An original and innovative procedure for concrete surface description was developed, which includes steps from the TLS measurement to the determination of the roughness parameters. The tested samples from anthropogenic soil, medium sand, and sandy gravel, map the real diaphragm wall surface. The surface roughness parameters in different soil layers were compared with the reference surface obtained by cast against steel formwork. The following parameters: Sa, Sdr, and Vmc are indicated as being the most useful in numerical description of the concrete surface type and in allowing the determination of the soil surface friction. The novelty of this study is the estimation of the parameter δ (friction angle between the retaining wall surface and the soil), which is, among others, a function of the wall surface roughness. The influence of the type of surface on earth pressure are generally recognized in laboratory tests. Based on the estimated in situ values of δ, the more reliable active and passive pressure coefficients Ka, Kp were calculated for the tested soil layers. The conducted study has a practical significance for designing of retaining construction and makes progress in determination of surface roughness required in Eurocode 7.

3.
Materials (Basel) ; 13(11)2020 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-32503189

RESUMO

The importance of surface roughness and its non-destructive examination has often been emphasised in structural rehabilitation. The presented innovative procedure enables the estimation of concrete-to-concrete strength based on a combination of low-cost, area-limited tests and geostatistical methods. The new method removes the shortcomings of the existing one, i.e., it is neither qualitative nor subjective. The interface strength factors, cohesion and friction, can be estimated accurately based on the collected data on a surface texture. The data acquisition needed to create digital models of the concrete surface can be performed by terrestrial close-range photogrammetry or other methods. In the presented procedure, limitations to the availability of concrete surfaces are overcome by the generation of subsequential Gaussian random fields (via height profiles) based on the semivariograms fitted to the digital surface models. In this way, the randomness of the surface texture is reproduced. The selected roughness parameters, such as mean valley depth and, most importantly, the geostatistical semivariogram parameter sill, were transformed into contact bond strength parameters based on the available strength tests. The proposed procedure estimates the interface bond strength based on the geostatistical methods applied to the numerical surface model and can be used in practical and theoretical applications.

4.
Sensors (Basel) ; 19(5)2019 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-30818847

RESUMO

This article presents in situ research on the side surface of continuous flight auger (CFA) foundation piles using a three-dimensional (3D) laser scanner (Leica ScanStation C10) in order to evaluate the morphology assessment of pile concrete surfaces in various geotechnical layers. Terrestrial laser scanning describes the 3D geometry of the construction with high spatial resolution and accuracy. A total of six areas were selected from the acquired point cloud for which a two-step approach for removing the form was applied. In the first step, the reference surface was fitted using the least squares method, and then, cylindrical projection of the surface was performed. In the second step, an operator of removal of the multi-plane form was applied. For each sample, height parameters (Sq, Ssk, Sku, Sp, Sv, Sz, Sa) and functional volume parameters (Vmp, Vmc, Vvc, Vvv) according to the standard ISO 25178-2:2012 were determined. Significant differences in the values of surface height and functional volume parameters were observed for each geotechnical layer where piles were formed. Because the piles remain embedded in the ground, in situ tests of the side surface of piles are rarely performed and taken into account in the assessment of pile bearing capacity. The study of surface topography is a crucial stage in the assessment of the shear strength at the interface between a concrete pile and the soil layer. The obtained concrete morphology assessments are applicable during the determination of the skin friction factor in the analytical or numerical estimation of pile shaft resistance. The proposed procedure of morphology evaluation may improve the fidelity of the assumed friction factor between the concrete and soil and increase the reliability of direct shear experiments.

5.
Sensors (Basel) ; 18(11)2018 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-30469396

RESUMO

Static load tests of foundation piles are the basic method for the designing or verification of adopted design solutions which concern the foundation of a building structure. Preparation of a typical test station using the so-called inverted beam method is very expensive and labor-intensive. The settlement values of the loaded pile are usually recorded using accurate dial gauges. These gauges are attached to a reference beam located in close proximity to the pile under test, which may cause systematic errors (difficult to detect) caused by the displacement of the adopted reference beam. The application of geodetic methods makes it possible to maintain an independent, external reference system, and to verify the readouts from dial gauges. The article presents an innovative instrumentation for a self-balanced stand for the static load test made from a closed-end, double steel pipe. Instead of typical, precise geometric leveling, the semi-automatic measuring techniques were used: motorized total station measurement and terrestrial laser scanning controlled by a computer. The processing of the acquired data made it possible to determine the vertical displacements of both parts of the examined pile and compare displacements with the results from the dial gauges. On the basis of the excess of the collected observations, it was possible to assess the accuracy, which confirmed the usefulness of measuring techniques under study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA