Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(7)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37049042

RESUMO

This study investigated the structural behavior of a beam-slab member fabricated using a steel C-Purlins beam carrying a profile steel sheet slab covered by a dry board sheet filled with recycled aggregate concrete, called a CBPDS member. This concept was developed to reduce the cost and self-weight of the composite beam-slab system; it replaces the hot-rolled steel I-beam with a steel C-Purlins section, which is easier to fabricate and weighs less. For this purpose, six full-scale CBPDS specimens were tested under four-point static bending. This study investigated the effect of using double C-Purlins beams face-to-face as connected or separated sections and the effect of using concrete material that contains different recycled aggregates to replace raw aggregates. Test results confirmed that using double C-Purlins beams with a face-to-face configuration achieved better concrete confinement behavior than a separate configuration did; specifically, a higher bending capacity and ductility index by about +10.7% and +15.7%, respectively. Generally, the overall bending behavior of the tested specimens was not significantly affected when the infill concrete's raw aggregates were replaced with 50% and 100% recycled aggregates; however, their bending capacities were reduced, at -8.0% and -11.6%, respectively, compared to the control specimen (0% recycled aggregates). Furthermore, a new theoretical model developed during this study to predict the nominal bending strength of the suggested CBPDS member showed acceptable mean value (0.970) and standard deviation (3.6%) compared with the corresponding test results.

2.
Materials (Basel) ; 15(9)2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-35591317

RESUMO

The aim of this paper is to investigate the flexural performance of a new steel-concrete composite beam system, which is required to carry higher loads when applied in flooring systems with less self-weight and cost compared with conventional composite beams. This new composite member is prepared by filling a single cold-formed steel C-section with concrete material that has varied lightweight-recycled aggregates. In addition, varied stiffening scenarios are suggested to improve the composite behavior of this member, since these cold-formed C-sections are of a slender cross-section and more likely to buckle and twist under high bending loads than those of hot-rolled C-sections. The influence of using four different lightweight-recycled aggregates that combine together in the infill concrete material was investigated. These recycled aggregates are recycled concrete aggregate (RCA), expanded polystyrene (EPS) beads, crumb rubber aggregates (CRA) and fine glass aggregates (FGA). For this purpose, 14 samples of cold-formed galvanized steel C-purlin were filled with concrete material (containing 0 to 100% recycled aggregates) which are experimentally tested under pure bending load, and 1 additional sample was tested without the filling material. Further numerical models were prepared and analyzed using finite element analysis software to investigate the effects of additional parameters that were not experimentally examined. Generally, the results confirm that filling the C-sections with concrete material that contains varied percentages of recycled aggregates offer significantly improved the flexural stiffness, bending capacity, and ductility performances. For example, using infill concrete materials with 0% and 100% recycled aggregate replacement increased the bending capacity of hollow C-section by about 11.4 and 8.6 times, respectively. Furthermore, stiffening of the concrete-filled C-sections with steel strips or screw connectors eventually improved the composite behavior of the specimens which led to an increase in their bending capacities accordingly, and this improvement enhanced more with an increased number of these strips and connectors.

3.
Materials (Basel) ; 14(12)2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-34203973

RESUMO

The study aims to investigate the fire performance of reinforced concrete (RC) slab fabricated from high volume fly ash inclusion with nano-silica (HVFANS) under ISO 834 load curve. The HVFANS concrete slab with dimensions of 1850 mm × 1700 mm × 200 mm was tested via an electrical furnace under an exposing temperature of 1100 °C for 120 min. The slab behaviour was evaluated in terms of residual compressive strength, temperature distribution along its thickness, spalling, and cracks. The results revealed that the slab was capable of maintaining 62.19% of its original compressive strength at room temperature after exposure to the above temperature. Moreover, the distribution of temperature revealed that the temperature of concrete cover and bottom reinforcement was less than 300 °C with a maximum spalling depth of 11 mm within the temperature range of 680 to 840 °C. Furthermore, the thermal conductivity index (K) of the HVFANS concrete was determined, and results indicated that thermal conductivity equalled 0.35 W/mK which is considered low, as compared with other concretes tested in current and previous studies.

4.
PLoS One ; 15(12): e0243293, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33332375

RESUMO

The main cause of problematic soil failure under a certain load is due to low bearing capacity and excessive settlement. With a growing interest in employing shallow foundation to support heavy structures, it is important to study the soil improvement techniques. The technique of using geosynthetic reinforcement is commonly applied over the last few decades. This paper aims to determine the effect of using geogrid Tensar BX1500 on the bearing capacity and settlement of strip footing for different types of soils, namely Al-Hamedat, Ba'shiqah, and Al-Rashidia in Mosul, Iraq. The analysis of reinforced and unreinforced soil foundations was conducted numerically and analytically. A series of conditions were tested by varying the number (N) and the width (b) of the geogrid layers. The results showed that the geogrid could improve the footing's bearing capacity and reduce settlement. The soil of the Al-Rashidia site was sandy and indicated better improvement than the other two sites' soils (clayey soils). The optimum geogrid width (b) was five times the footing width (B), while no optimum geogrid number (N) was obtained. Finally, the numerical results of the ultimate bearing capacity were compared with the analytical results, and the comparison showed good agreement between both the analyses and the optimum range published in the literature. The significant findings reveal that the geogrid reinforcement may induce improvement to the soil foundation, however, not directly subject to the width and number of the geogrid alone. The varying soil properties and footing size also contribute to both BCR and SRR values supported by the improvement factor calculations. Hence, the output complemented the benefit of applying reinforced soil foundations effectively.


Assuntos
Materiais de Construção , Solo , Argila/química , Materiais de Construção/análise , Fenômenos Geológicos , Iraque , Areia/química , Solo/química
5.
Polymers (Basel) ; 8(5)2016 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-30979298

RESUMO

In recent years, attention has been focused on elastomeric polymers as a potential retrofitting material considering their capability in contributing towards the impact resistance of various structural elements. A comprehensive understanding of the behavior and the morphology of this material are essential to propose an effective and feasible alternative to existing structural strengthening and retrofitting materials. This article presents the findings obtained from a series of experimental investigations to characterize the physical, mechanical, chemical and thermal behavior of eight types of palm-based polyurethane (PU) elastomers, which were synthesized from the reaction between palm kernel oil-based monoester polyol (PKO-p) and 4,4-diphenylmethane diisocyanate (MDI) with polyethylene glycol (PEG) as the plasticizer via pre-polymerization. Fourier transform infrared (FT-IR) spectroscopy analysis was conducted to examine the functional groups in PU systems. Mechanical and physical behavior was studied with focus on elongation, stresses, modulus, energy absorption and dissipation, and load dispersion capacities by conducting hardness, tensile, flexural, Izod impact, and differential scanning calorimetry tests. Experimental results suggest that the palm-based PU has positive effects as a strengthening and retrofitting material against dynamic impulsive loadings both in terms of energy absorption and dissipation, and load dispersion. In addition, among all PUs with different plasticizer contents, PU2 to PU8 (which contain 2% to 8% (w/w) PEG with respect to PKO-p content) show the best correlation with mechanical response under quasi-static conditions focusing on energy absorption and dissipation and load dispersion characteristics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...