Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1218(23): 3711-7, 2011 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-21543072

RESUMO

The development of a seven-component test mixture designed for use with a generic gradient and a reversed-phase high performance liquid chromatography-mass spectrometry (RP-HPLC-MS) system is discussed. Unlike many test mixtures formulated in order to characterise column quality at neutral pH, the test mixture reported here was designed to permit an overall suitability assessment of the whole liquid chromatography-mass spectrometry (LCMS) system. The mixture is designed to test the chromatographic performance of the column as well as certain aspects of the performance of the individual instrumental components of the system. The System Suitability Test Mix can be used for low and high pH generic reverse phase LCMS analysis. Four phthalates are used: diethyl phthalate (DEP), diamyl phthalate (DAP), di-n-hexyl phthalate (DHP) and dioctyl phthalate (DOP). Three other probes are employed: 8-bromoguanosine (8-BG), amitryptyline (Ami), and 4-chlorocinnamic acid (4-CCA). We show that analysis of this test mixture can alert the user when any part of the system (instrument or column) contributes to loss of overall performance and may require remedial action and demonstrate that it can provide information that enables us to document data quality control.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Espectrometria de Massas/métodos , Software , Amitriptilina/química , Automação , Cromatografia Líquida de Alta Pressão/normas , Cromatografia de Fase Reversa/normas , Cinamatos/química , Guanosina/análogos & derivados , Guanosina/química , Concentração de Íons de Hidrogênio , Espectrometria de Massas/normas , Ácidos Ftálicos/química , Padrões de Referência
3.
Anal Chem ; 77(14): 4354-65, 2005 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-16013846

RESUMO

There is an urgent need for detection technologies that enable accurate and precise quantification of solutions containing small organic molecules in a manner that is rapid, cheap, non-labor-intensive, readily automated, and without a requirement for specific analyte standards. We provide a theoretical analysis that predicts that the logarithmic nature of the working domain of the evaporative light-scattering detector (ELSD) will normally bias toward underestimation of chromatographically resolved impurities, resulting in an overestimation of analyte purity. This analysis is confirmed by experiments with flow injection analysis (FIA) and gradient reversed-phase high performance liquid chromatography (RP-HPLC). Quantification is further compromised by the dependence of response parameters on the matrix composition and hence on the retention time of the analyte. Attempts were made to ameliorate these problems by using the response surface of a single compound to calibrate throughout the HPLC gradient. A chemiluminescent nitrogen detector (CLND) was also used in a similar manner, and the performance of the two techniques were compared against those of each other and that of a reference standard technique. A protocol for this purpose was developed using proton nuclear magnetic resonance (1H NMR) and the ERETIC method to enable quantification by integrating proton signals. The double-blind comparison exercise confirmed molar nitrogen CLND response to be sufficiently stable and robust across a methanol gradient to be used with a single external nitrogenous calibrant to quantify nitrogen-containing compounds of known molecular formula. The performance of HPLC-CLND was very similar to that of NMR, while that of HPLC-ELSD was seen to be significantly worse, showing it to be unsuitable for the purpose of single-calibrant quantification. We report details and experience of our use of RP-HPLC-CLND-MS to characterize and quantify small amounts of solutions of novel compounds at nominal levels of 10mM in microtiter plate (MTP) format.

4.
Chirality ; 15 Suppl: S1-S12, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12884369

RESUMO

Pharmaceutical companies have a continuous need to resolve new racemates. Analysis may be required in aqueous and nonaqueous media, or in the presence of several different sets of potentially interfering compounds. There is often a preparative requirement. For these reasons analysts may require a number of different separation systems capable of resolving a given pair of enantiomers. We wished to improve upon existing approaches that address this situation and undertook a program of work to screen over 100 racemates, selected for their chemical diversity, on over 100 different chiral HPLC, SFC, and CE systems. Here we report results of this comparison and illustrate the use of rapid gradient screening as a valuable tool for chiral method development.

5.
Angew Chem Int Ed Engl ; 37(19): 2661-2663, 1998 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-29711622

RESUMO

The biomimetic synthesis of a pentacyclic alkaloid (keramaphidin B, 1), an intermediate in the biogenetic pathway to the manzamine alkaloids, has been achieved. Compound 1 was formed by an intramolecular Diels-Alder reaction of macrocycle 2 in buffer followed by reduction with NaBH4 . This reaction provides the first direct expeimental evidence for the authors' biosynthetic hypothesis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...