Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1720: 464769, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38442499

RESUMO

In this study, we introduce a novel approach for the analysis of salivary ions using capillary electrophoresis (CE) with a triple-layer coated capillary. The capillary is sequentially coated with cationic silylating reagents, poly(vinylsulfonate), and polybrene to form a custom designed surface that effectively inhibits adsorption of protein matrix on the capillary inner wall and allows for reproducible ion analysis. For the CE with capacitively coupled contactless conductivity detection, we used suitable background electrolytes (BGEs) for salivary ion analysis. Anions were separated using a mixture of 2-(N-morpholino)ethanesulfonic acid and l-arginine, and cations were separated using that with 18-crown-6. This setup enabled rapid separation, within 4 min, together with sensitive detection. We quantified nine common anions and five cations typically found in saliva samples using this CE method, both before and after a cold pressure test (CPT, a standard stress test). The CE system demonstrated consistent ion separation across 30 consecutive measurements without requiring capillary replacement. Notably, the salivary ion balance remained predominantly anion-rich, regardless of the CPT. Cold water exposure induced greater variation in the total anion concentration than in the total cation concentration. Further analysis using multiple regression analysis revealed strong relationships between nitrate and nitrite, formate and phosphate, and potassium and nitrate, before and after the CPT. Notably, potassium and nitrate ions exhibited variations in response to stress. These results provided a method for assessing salivary ion composition and insights into the potential of salivary ions as biomarkers for stress.


Assuntos
Eletroforese Capilar , Nitratos , Cátions/análise , Ânions/análise , Eletroforese Capilar/métodos , Água , Potássio
2.
J Chromatogr A ; 1635: 461647, 2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33291035

RESUMO

This paper describes the simultaneous capillary electrophoresis (CE) of anions and cations using an anion exchange-modified capillary, which was prepared by chemical coating with a cationic silylating reagent, and its application to saliva analysis. The CE method provides high-throughput (5 min for a single sample injection) analysis by generating a high-velocity electroosmotic flow at pH 3.0-3.5. The detection limits at a signal-to-noise ratio of 3 ranged from 1.2 to 18 µM for anions and 1.0 to 2.7 µM for cations. The relative standard deviations for the migration times and peak areas of analytes (n = 4) ranged from 0.05% to 0.40% and 0.94% to 4.7%, respectively. The CE system was used to analyze 11 common ions in saliva samples collected from long-distance runners and sedentary university students before and after running for a set distance or a set time. Interestingly, the SCN- concentrations decreased in the saliva samples of all 14 athletes and 16 sedentary students after running. Furthermore, when the concentrations of the analyzed ions were compared with that of cortisol as a typical stress marker by multiple regression analysis, SCN- and NO3- in saliva samples from the two subject groups strongly correlated with cortisol levels, as determined by an electrochemiluminescence immunoassay. This study improves our knowledge of both the analytical methodology for CE and statistical methods for identifying common ions that could be used as physical stress markers.


Assuntos
Ânions/isolamento & purificação , Cátions/isolamento & purificação , Eletroforese Capilar/métodos , Saliva/química , Biomarcadores/análise , Eletro-Osmose , Humanos , Indicadores e Reagentes , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...