Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 109: 24-29, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26682890

RESUMO

Preparation methods for (133)Xe standards of activity concentration and the results of the 2014 (133)Xe laboratory inter-comparison exercise are described. One element of the quality assurance/quality control (QA/QC) program for laboratories of the International Monitoring System (IMS) will be regular inter-comparison exercises. However, until recently, no activity concentration standards for benchmarking were available. Therefore, two (133)Xe activity concentration reference standards were produced independently by Idaho National Laboratory and Seibersdorf Laboratories and used for the 2014 laboratory inter-comparison exercise. The preparation of a complementary (127)Xe activity concentration standard as well as a (127)Xe laboratory inter-comparison exercise suggests (127)Xe as a suitable isotope for QA/QC of remote IMS noble gas stations.

2.
Appl Radiat Isot ; 89: 176-85, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24657473

RESUMO

(127)Xe has a longer half-life than (131m)Xe, it can be easily purely produced and it is present in the environment at very low level. For these reasons, (127)Xe is supposed to be a convenient quality control radionuclide for remote noble gas stations of the International Monitoring System (IMS) network. As CEA/DAM has recently developed two new photon/electron setups for low-level detection of (131m)Xe, (133m)Xe, (133)Xe and (135)Xe, we took the opportunity to test these setups for the measurement of a (127)Xe standard. The results and a detailed description of these measurements are presented in this paper. They illustrate the complexity of (127)Xe decay, emitting simultaneously several γ, X-rays, conversion electrons and Auger electrons; this results in highly summated coincidence spectra. The measurements performed provide precise electron energy calibration of the setups. The count rate of electrons in coincidence with iodine Kα X-rays was found to be surprisingly low, leading to the study of electron-gated photon spectrum. Finally, a comparison of three photon/electron coincidence spectra obtained with three different setups is given. The use of (127)Xe as a standard for energy calibration of IMS noble gas station is possible, but it appears to be quite complicated for efficiency check of noble gas station equipped with ß/γ detectors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...