Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(7): 1311-1316, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37890001

RESUMO

BACKGROUND: Vascular complications following transfemoral TAVR are associated with increased morbidity and mortality. Measures that may mitigate this risk are important. AIM: To evaluate the utility of routine, access-vessel angiography post sheath-removal in the detection and management of complications in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: This was a retrospective study of 512 consecutive patients who underwent transfemoral TAVR with routine post access-closure angiography from the radial artery. Rates of mild angiographically evident bleeding, bleeding requiring surgery/interventional-radiology, ischemia, 90-day access-site-related events, and major and minor vascular complications using Valve Academic Research Consortium 3 definitions were recorded. RESULTS: Of 512 patients, digital subtraction angiography (DSA) was undertaken via the radial artery in 467 patients (91%). In the remaining patients (9%) DSA was either not attempted, due to concerns regarding kidney disease and contrast volume, or failed due to anatomical factors (aortic tortuosity/calcification). Significant chronic kidney disease was present at baseline in 72.4% of this cohort (stages III-IV or dialysis). Ninety-four percent of cases underwent TAVR using a balloon-expandable platform. Mild iliofemoral extravasation was observed in 7.7% of the DSA cases. These cases were managed by manual compression with none requiring any vascular intervention subsequently. Valve Academic Research Consortium 3 major and minor access-site-related complications were observed in 0.4% and 12.2%, respectively. Access-site-related bleeding and ischemic events requiring interventional-radiology or vascular-surgery were observed in 0.9% and 1.7% of the DSA cases, respectively. No new renal replacement therapy was needed in any of the DSA cases. Discharge to 90-day access-related complications was 0.8%. CONCLUSIONS: Routine post access-closure angiography is feasible via the radial artery in patients undergoing transfemoral TAVR and appears safe. It facilitates early identification of complications and mitigates risk by enabling prompt action to be taken. Larger studies are needed to confirm these findings.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Fatores de Risco , Artéria Femoral , Resultado do Tratamento , Hemorragia/etiologia , Angiografia Digital/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
2.
Catheter Cardiovasc Interv ; 101(3): 660-667, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36640417

RESUMO

Transcatheter aortic valve replacement (TAVR) has revolutionized the management of severe symptomatic aortic valve stenosis. TAVR is now indicated as an alternative to surgical replacement in a wide risk profile ranging from high to low surgical risk. Although vascular complications have decreased in frequency over time, with the introduction of lower profile delivery systems and sheaths, they remain one of the most frequently encountered and serious complications of TAVR. Patient-specific predisposing factors have been well characterized. However, much less is known about device-specific complications. Awareness of the possible device-related complications may lead to earlier identification, prompt management, and better outcomes. We report a previously unreported complication of the Edwards expandable eSheath that lead to avulsion of the external iliac artery following successful TAVR with a 29-mm Edwards Sapien 3 transcatheter heart valve. Bleeding was promptly controlled with an occlusion balloon and emergency surgical repair was required with a favorable outcome.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
4.
Circ Heart Fail ; 7(3): 440-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24619369

RESUMO

BACKGROUND: A paradoxical inspiratory rise in right atrial pressure (in contrast to the normal fall during inspiration), Kussmaul sign, has been described in congestive heart failure (CHF). However, the clinical and hemodynamic characteristics and clinical outcomes of patients with CHF and Kussmaul physiology have not been studied. METHODS AND RESULTS: This is a single-center study of consecutive ambulant patients with CHF (New York Heart Association class III/IV) referred for assessment for heart transplantation between November 2011 and April 2013. Kussmaul physiology was defined as inspiratory rise in right atrial pressure during right heart catheterization. Clinical, biochemical, echocardiographic, and hemodynamic correlates were studied and outcomes assessed in patients with or without Kussmaul physiology after a mean follow-up of 379±227 days. Ninety ambulant patients (age, 53±12 years; 86% men) with CHF were studied. Kussmaul physiology was demonstrated in 39 (43%) patients, and it was associated with higher pulmonary pressures and lower cardiac index and pulmonary capacitance (all P<0.05). Patients with Kussmaul physiology were more likely to be treated with higher doses of diuretics, while higher filling pressures, N-terminal pro-B natriuretic peptide levels, and hyponatremia reflected greater neurohormonal activation. Echocardiography revealed greater left and right ventricular dimensions/volumes, restrictive transmitral filling pattern, and lower left ventricular ejection fraction and lower tricuspid annular plane systolic excursion. Peak oxygen uptake was low and comparable in both groups, but ventilation slope was higher in patients with Kussmaul physiology who also had a higher incidence of post-transplant right ventricular failure and overall mortality (P<0.05). CONCLUSIONS: Kussmaul physiology is common in patients with CHF referred for heart transplantation and is associated with adverse cardiopulmonary hemodynamics. As a result of the latter, Kussmaul physiology is associated with poorer clinical outcomes. Kussmaul physiology may be useful during assessment of right heart function and pulmonary pressures before transplantation.


Assuntos
Cateterismo Cardíaco , Átrios do Coração/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/fisiologia , Inalação/fisiologia , Adulto , Idoso , Doença Crônica , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Consumo de Oxigênio/fisiologia , Fragmentos de Peptídeos/sangue , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...