1.
Int J Legal Med ; 130(3): 751-7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26496804

RESUMO

In contact shots, the muzzle imprint is an informative finding associated with the entrance wound. It typically mirrors the constructional components being in line with the muzzle or just behind. Under special conditions, other patterned skin marks located near a gunshot entrance wound may give the impression to be part of the muzzle imprint. A potential mechanism causing a patterned pressure abrasion in close proximity to the bullet entrance site is demonstrated on the basis of a suicidal shot to the temple. The skin lesion in question appeared as a ring-shaped excoriation with a diameter corresponding to that of the cartridge case. Two hypotheses concerning the causative mechanism were investigated by test shots: - After being ejected, the cartridge case ricocheted inside a confined space (car cabin in the particular case) and secondarily hit the skin near the gunshot entrance wound. - The ejection of the cartridge case failed so that the case became stuck in the ejection port and its mouth contacted the skin when the body collapsed after being hit.


Assuntos
Traumatismos Cranianos Penetrantes/patologia , Suicídio , Ferimentos por Arma de Fogo/patologia , Idoso , Armas de Fogo , Humanos , Masculino
2.
Arch Kriminol ; 236(3-4): 73-84, 2015.
Artigo em Alemão | MEDLINE | ID: mdl-26548032

RESUMO

On 26 Nov 2012, a serious fire occurred at Neustadt/Black Forest in which 14 persons in a sheltered workshop died and 10 other individuals were injured. The fire was caused by the unbridled escape of propane gas due to accidental disconnection of the screw fixing between a gas bottle and a catalytic heater. Deflagration of the propane gas-air mixture set the workshop facilities on fire. In spite of partly extensive burns the fatally injured victims could be rapidly identified. The results of the fire investigations at the scene and the autopsy findings are presented. Carboxyhemoglobin concentrations ranged between 8 and 56 % and signs of fire fume inhalation were present in all cases. Three victims had eardrum ruptures due to the sudden increase in air pressure during the deflagration.


Assuntos
Traumatismos por Explosões/patologia , Queimaduras/patologia , Explosões/classificação , Incêndios , Traumatismo Múltiplo/patologia , Propano , Ar , Medicina Legal/métodos , Alemanha , Humanos
3.
Int J Legal Med ; 129(1): 125-31, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25119685

RESUMO

In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.


Assuntos
Armas de Fogo , Gases , Pós , Suicídio , Ferimentos por Arma de Fogo/patologia , Diafragma/lesões , Diafragma/patologia , Balística Forense , Gelatina , Ruptura Cardíaca/patologia , Humanos , Fígado/lesões , Fígado/patologia , Pessoa de Meia-Idade , Modelos Biológicos , Traumatismos Torácicos/patologia
4.
Arch Kriminol ; 231(5-6): 183-92, 2013.
Artigo em Alemão | MEDLINE | ID: mdl-23878897

RESUMO

Report on the clinical and medicolegal findings in a survived suicide attempt by hanging. A 39-year-old woman was found unconscious in a crouching position on the balcony of her flat. The hanging device was an electric cable running around her neck in a single loop and attached to the balcony wall. After removing the noose, resuscitation measures were started immediately. For 5 hours, the victim was at first in a comatose and then in a somnolent state. The period of amnesia covered also the preparations for the suicidal act. The forensic examination performed on the same day showed a reddish, streak-like hanging mark, pronounced signs of blood congestion with dense petechial haemorrhages in the facial skin, confluent haemorrhages in the conjunctivae as well as bleeding from the left external auditory canal. BAC was 2.2 per mil. On the basis of the findings and the clinical course, criminalistic and pathophysiological aspects of near-hanging are discussed.


Assuntos
Asfixia/patologia , Lesões do Pescoço/patologia , Tentativa de Suicídio/legislação & jurisprudência , Adulto , Diagnóstico Diferencial , Prova Pericial/legislação & jurisprudência , Feminino , Escala de Coma de Glasgow , Homicídio/legislação & jurisprudência , Humanos , Exame Neurológico , Pele/lesões , Pele/patologia
5.
Forensic Sci Int ; 231(1-3): e30-2, 2013 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-23791381

RESUMO

Suicides by self-poisoning are common in all parts of the world. Among these intoxications, gases are rarely used, especially carbon dioxide (CO2). Very few cases of self-inflicted and deliberate carbon dioxide poisonings have been reported. This paper presents two uncommon suicides by carbon dioxide intoxication. In one case, a 53-year-old man tightly sealed a small bathroom and locked himself in it likely with dry ice. Warning notices were tagged to the door. In another case, a 48-year-old man working in a restaurant committed suicide by closing himself in a walk-in refrigerator and opening the stored carbon dioxide containers intended for the beverage dispensing equipment. The limited possibilities of proving lethal CO2 intoxications post-mortem necessitate a close cooperation of the involved parties during investigation. Only the synopsis of all findings permits a sound assessment regarding the manner and cause of death.


Assuntos
Dióxido de Carbono/intoxicação , Espaços Confinados , Suicídio , Edema Encefálico/patologia , Gelo-Seco/efeitos adversos , Etanol/análise , Patologia Legal , Toxicologia Forense , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Edema Pulmonar/patologia
6.
Int J Legal Med ; 127(4): 791-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23250385

RESUMO

In current forensic practice, fatal injuries from black powder guns are rare events. In contact and close-range shots, the intensity of GSR deposition (soot, powder particles) is much greater than that in shots with smokeless powder ammunition. The same applies to any burning effects from the combustion gases. Besides, a wad of felt interposed between the propellant and the lead bullet may enter the wound channel. Apart from these findings seen in close-range shots, another characteristic feature results from the mostly spherical shape of the missiles causing maximum tissue damage at the entrance site. Two fatal injuries inflicted with muzzle-loading weapons are reported. In the first case, suicide was committed with a cal. 11.6 mm miniature cannon by firing a contact shot to the back of the neck. In test shots using black powder (1 and 2 g) as propellant, the mean bullet velocity measured 1 m away from the weapon was 87.11 and 146.85 m/s, respectively, corresponding to a kinetic energy of 32.49 and 92.95 J, respectively. Contact test shots to composite models consisting of ballistic soap covered by pig skin at the entrance site were evaluated by CT and revealed cone-like cavitations along the bullet path as known from spherical missiles and penetration depths up to 25 cm. The second case presented deals with a homicidal close-range shot discharged from a muzzle-loading percussion pistol cal. .44. The skin around the entrance site (root of the nose) was densely covered with blackish soot and powder particles, whereas the eyebrows and eyelashes showed singeing of the hairs. The flattened bullet and the wad had got stuck under the scalp of the occipital region. In both cases, there was a disproportionally large zone of tissue destruction in the initial parts of the wound tracks.


Assuntos
Armas de Fogo , Modelos Biológicos , Ferimentos por Arma de Fogo/patologia , Idoso , Animais , Desenho de Equipamento , Balística Forense , Patologia Legal , Homicídio , Humanos , Masculino , Pessoa de Meia-Idade , Pele/lesões , Pele/patologia , Sabões , Fuligem , Suicídio , Suínos
7.
Arch Kriminol ; 227(1-2): 23-32, 2011.
Artigo em Alemão | MEDLINE | ID: mdl-21404548

RESUMO

A 42-year-old man evidently had died from an intoxication. On the basis of the findings at scene it was primarily assumed that the man had ingested a larger quantity of an ethylene glycol-containing antifreeze for suicidal purposes. The man was said to have had an alcohol problem and did not only consume drinking alcohol, but also other alcoholic liquids. At autopsy, a bluish liquid with an aromatic smell was found in the oesophagus and stomach. However, toxicological analyses did not furnish evidence of ethylene glycol--as expected--but a potentially fatal concentration of ethanol (blood alcohol concentration 4.01 per mille). The blue colour (patent blue C.I.42051) came from a liquid used in the wind-screen washer system in winter, which now contains ethanol (denatured with 2-butanone) instead of ethylene glycol. The results of the toxicological findings including the analysis of congener alcohols and the differential diagnostics of blue-coloured stomach contents are discussed.


Assuntos
Intoxicação Alcoólica/patologia , Autopsia/legislação & jurisprudência , Conteúdo Gastrointestinal/química , Pigmentação , Suicídio/legislação & jurisprudência , Adulto , Diagnóstico Diferencial , Etilenoglicol/intoxicação , Mucosa Gástrica/patologia , Alemanha , Humanos , Masculino
8.
Int J Legal Med ; 125(4): 479-85, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20936481

RESUMO

Suicidal shots fired simultaneously to the head from two handguns are rare. The authors report about a recent case in which a Smith & Wesson cal. 9 mm pistol and a Smith & Wesson cal. .357 Magnum revolver were used. Sitting on a sofa, a 33-year-old man (member of a shooting club) fired two simultaneous shots to the head; the pistol held in the left hand was discharged into the left temple, and the revolver held in the right hand was fired into the mouth. Both weapons remained in the respective hands. An upside-down muzzle imprint in the left temporal region and recoil injuries of a mandibular incisor, and the lower lip indicated that both the pistol and the revolver had been held in an inverted manner at the time of discharge. Blood stains (backspatter) and gunshot residues were present on both firing hands, whereas forward spatter originating from the exit wounds was deposited on the wall behind the suicide's head.


Assuntos
Comportamento Cooperativo , Armas de Fogo/legislação & jurisprudência , Traumatismos Cranianos Penetrantes/patologia , Comunicação Interdisciplinar , Suicídio/legislação & jurisprudência , Ferimentos por Arma de Fogo/patologia , Adulto , Autopsia , Manchas de Sangue , Humanos , Masculino , Metais/análise , Microscopia Eletrônica de Varredura , Palato/lesões , Palato/patologia , Espectrometria por Raios X
9.
Int J Legal Med ; 124(6): 605-12, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20393855

RESUMO

Apart from one article published by Rabl and Sigrist in 1992 (Rechtsmedizin 2:156-158), there are no further reports on secondary skull fractures in shots from captive bolt guns. Up to now, the pertinent literature places particular emphasis on the absence of indirect lesions away from the impact point, when dealing with the wounding capacity of slaughterer's guns. The recent observation of two suicidal head injuries accompanied by skull fractures far away from the bolt's path gave occasion to experimental studies using simulants (glycerin soap, balls from gelatin) and skull­brain models. As far as ballistic soap was concerned, the dimensions of the bolt's channel were assessed by multi-slice computed tomography before cutting the blocks open. The test shots to gelatin balls and to skull-brain models were documented by means of a high-speed motion camera. As expected, the typical temporary cavity effect of bullets fired from conventional guns could not be observed when captive bolt stunners were discharged. Nevertheless, the visualized transfer of kinetic energy justifies the assumption that the secondary fractures seen in thin parts of the skull were caused by a hydraulic burst effect.


Assuntos
Lesões Encefálicas/patologia , Armas de Fogo , Balística Forense/métodos , Fraturas Ósseas/patologia , Modelos Anatômicos , Ferimentos por Arma de Fogo/patologia , Autopsia , Humanos , Masculino , Pessoa de Meia-Idade , Suicídio
10.
Forensic Sci Int ; 171(1): e11-4, 2007 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-17560746

RESUMO

A 51-year-old woman with a psychiatric history of depression and drug abuse was found hanged in her bedroom. The ligature was a scarf attached to the door handle. The autopsy findings suggested that two methods of suicide had been used one after the other. In the first stage, numerous nails, pins and needles were swallowed; in the second stage, the suicide was completed by hanging.


Assuntos
Corpos Estranhos/patologia , Suicídio , Asfixia/patologia , Feminino , Patologia Legal , Psiquiatria Legal , Humanos , Métodos , Pessoa de Meia-Idade , Agulhas
11.
Arch Kriminol ; 213(1-2): 15-21, 2004.
Artigo em Alemão | MEDLINE | ID: mdl-15012039

RESUMO

Report on a case in which an 8-year-old girl was injured on the left anterior thoracic wall by two shots fired by her 14-year-old cousin from a soft-air pistol (replica of mod. 17 make Glock, cal. 6 mm, solid plastic bullets); the projectiles caused two skin lesions, both reaching into the subcutis. The results of our own shooting tests with 2 different soft-air pistols and the injuries seen in our case confirm that soft-air pistols may cause penetrating soft-tissue injuries when fired from a short distance.


Assuntos
Mama/lesões , Armas de Fogo/legislação & jurisprudência , Lesões dos Tecidos Moles/patologia , Violência/legislação & jurisprudência , Ferimentos por Arma de Fogo/patologia , Adolescente , Asfixia/patologia , Mama/patologia , Criança , Túnica Conjuntiva/patologia , Doenças da Túnica Conjuntiva/patologia , Hemorragia Ocular/patologia , Feminino , Humanos , Masculino , Púrpura/patologia , Pele/patologia
12.
Arch Kriminol ; 209(5-6): 138-46, 2002.
Artigo em Alemão | MEDLINE | ID: mdl-12134756

RESUMO

The article reports on the injury pattern seen in fatally wounded car passengers after rear-end collisions on motorways. The study material included 5 rear-end collisions, in which 9 car occupants (5 drivers and 4 front-seat passengers) were killed. The change in velocity (delta v) was above 60 km/h in all the reported cases. The injury pattern showed the following characteristics: extensive soft-tissue traumatization (subcutaneous haematomas, blood-filled pockets, "décollements") not discernible from outside on the back of the trunk, mostly in the lumbosacral region; dorsal serial rib fractures, often combined with fractures of the spine (including the sacrum and the coccyx) and/or the pelvis; ruptures of the aorta at the typical sites of predisposition; ruptures of the liver and spleen (particularly at the visceral surfaces).


Assuntos
Acidentes de Trânsito/mortalidade , Causas de Morte , Ferimentos e Lesões/mortalidade , Acidentes de Trânsito/legislação & jurisprudência , Adulto , Idoso , Autopsia/legislação & jurisprudência , Prova Pericial/legislação & jurisprudência , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/mortalidade , Traumatismo Múltiplo/patologia , Ferimentos e Lesões/patologia
SELEÇÃO DE REFERÊNCIAS