Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
AJNR Am J Neuroradiol ; 45(5): 562-567, 2024 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-38290738

RESUMO

BACKGROUND AND PURPOSE: The DWI-FLAIR mismatch is used to determine thrombolytic eligibility in patients with acute ischemic stroke when the time since stroke onset is unknown. Commercial software packages have been developed for automated DWI-FLAIR classification. We aimed to use e-Stroke software for automated classification of the DWI-FLAIR mismatch in a cohort of patients with acute ischemic stroke and in a comparative analysis with 2 expert neuroradiologists. MATERIALS AND METHODS: In this retrospective study, patients with acute ischemic stroke who had MR imaging and known time since stroke onset were included. The DWI-FLAIR mismatch was evaluated by 2 neuroradiologists blinded to the time since stroke onset and automatically by the e-Stroke software. After 4 weeks, the neuroradiologists re-evaluated the MR images, this time equipped with automated predicted e-Stroke results as a computer-assisted tool. Diagnostic performances of e-Stroke software and the neuroradiologists were evaluated for prediction of DWI-FLAIR mismatch status. RESULTS: A total of 157 patients met the inclusion criteria. A total of 82 patients (52%) had a time since stroke onset of ≤4.5 hours. By means of consensus reads, 81 patients (51.5%) had a DWI-FLAIR mismatch. The diagnostic accuracy (area under the curve/sensitivity/specificity) of e-Stroke software for the determination of the DWI-FLAIR mismatch was 0.72/90.0/53.9. The diagnostic accuracy (area under the curve/sensitivity/specificity) for neuroradiologists 1 and 2 was 0.76/69.1/84.2 and 0.82/91.4/73.7, respectively; both significantly (P < .05) improved to 0.83/79.0/86.8 and 0.89/92.6/85.5, respectively, following the use of e-Stroke predictions as a computer-assisted tool. The interrater agreement (κ) for determination of DWI-FLAIR status was improved from 0.49 to 0.57 following the use of the computer-assisted tool. CONCLUSIONS: This automated quantitative approach for DWI-FLAIR mismatch provides results comparable with those of human experts and can improve the diagnostic accuracies of expert neuroradiologists in the determination of DWI-FLAIR status.


Assuntos
Imagem de Difusão por Ressonância Magnética , AVC Isquêmico , Humanos , Masculino , Feminino , AVC Isquêmico/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Software , Idoso de 80 Anos ou mais , Sensibilidade e Especificidade , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes
2.
Interv Neuroradiol ; : 15910199231224500, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38258456

RESUMO

BACKGROUND AND PURPOSE: In patients with acute ischemic stroke (AIS), overestimation of ischemic core on MRI-DWI has been described primarily in regions with milder reduced diffusion. We aimed to assess the possibility of ischemic core overestimation on pretreatment MRI despite using more restricted reduced diffusion (apparent diffusion coefficient (ADC) ≤620 × 10-6 mm2/s) in AIS patients with successful reperfusion. MATERIALS AND METHODS: In this retrospective single institutional study, AIS patients who had pretreatment MRI underwent successful reperfusion and had follow-up MRI to determine the final infarct volume were reviewed. Pretreatment ischemic core and final infarction volumes were calculated. Ghost core was defined as overestimation of final infarct volume by baseline MRI of >10 mL. Baseline clinical, demographic, and treatment-related factors in this cohort were reviewed. RESULTS: A total of 6/156 (3.8%) patients had overestimated ischemic core volume on baseline MRI, with mean overestimation of 65.6 mL. Three out of six patients had pretreatment ischemic core estimation of >70 mL, while the final infarct volume was <70 mL. All six patients had last known well-to-imaging <120 min, median (IQR): 65 (53-81) minutes. CONCLUSIONS: Overestimation of ischemic core, known as ghost core, is rare using severe ADC threshold (≤620 × 10-6 mm2/s), but it does occur in nearly 1 of every 25 patients, confined to hyperacute patients imaged within 120 min of symptom onset. Awareness of this phenomenon carries implications for treatment and trial enrollment.

3.
J Stroke Cerebrovasc Dis ; 32(11): 107297, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37738915

RESUMO

BACKGROUND AND PURPOSE: CTP is increasingly used to assess eligibility for endovascular therapy (EVT) in patients with large vessel occlusions (LVO). There remain variability and inconsistencies between software packages for estimation of ischemic core. We aimed to use heterogenous data from four stroke centers to perform a comparative analysis for CTP-estimated ischemic core between RAPID (iSchemaView) and Olea (Olea Medical). METHODS: In this retrospective multicenter study, patients with anterior circulation LVO who underwent pretreatment CTP, successful EVT (defined TICI ≥ 2b), and follow-up MRI included. Automated CTP analysis was performed using Olea platform [rCBF < 25% and differential time-to-peak (dTTP)>5s] and RAPID (rCBF < 30%). The CTP estimated core volumes were compared against the final infarct volume (FIV) on post treatment MRI-DWI. RESULTS: A total of 151 patients included. The CTP-estimated ischemic core volumes (mean ± SD) were 18.7 ± 18.9 mL on Olea and 10.5 ± 17.9 mL on RAPID significantly different (p < 0.01). The correlation between CTP estimated core and MRI final infarct volume was r = 0.38, p < 0.01 for RAPID and r = 0.39, p < 0.01 for Olea. Both software platforms demonstrated a strong correlation with each other (r = 0.864, p < 0.001). Both software overestimated the ischemic core volume above 70 mL in 4 patients (2.6%). CONCLUSIONS: Substantial variation between Olea and RAPID CTP-estimated core volumes exists, though rates of overcalling of large core were low and identical. Both showed comparable core volume correlation to MRI infarct volume.

4.
AJNR Am J Neuroradiol ; 43(6): 887-892, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35672082

RESUMO

BACKGROUND AND PURPOSE: Differential Subsampling with Cartesian Ordering (DISCO), an ultrafast high-spatial-resolution head MRA, has been introduced. We aimed to determine the diagnostic performance of DISCO-MRA in grading residual aneurysm in comparison with TOF-MRA in patients with treated intracranial aneurysms. MATERIALS AND METHODS: Patients with endovascular treatment and having undergone DISCO-MRA, TOF-MRA, and DSA were included for review. The voxel size and acquisition time were 0.75 × 0.75 × 1 mm3/6 seconds for DISCO-MRA and 0.6 × 0.6 × 1 mm3/6 minutes for TOF-MRA. Residual aneurysms were determined using the Modified Raymond-Roy Classification on TOF-MRA and DISCO-MRA by 2 neuroradiologists independently and were compared against DSA as the reference standard. Statistical analysis was performed using the κ statistic and the χ2 test. RESULTS: Sixty-eight treated intracranial aneurysms were included. The intermodality agreement was κ = 0.82 (95% CI, 0.67-0.97) between DISCO and DSA and 0.44 (95% CI, 0.28-0.61) between TOF and DSA. Modified Raymond-Roy Classification scores matched DSA scores in 60/68 cases (88%; χ2 = 144.4, P < .001 for DISCO and 46/68 cases (68%; χ2 = 65.0, P < .001) for TOF. The diagnostic accuracy for the detection of aneurysm remnants was higher for DISCO (0.96; 95% CI, 0.88-0.99) than for TOF (0.79; 95% CI, 0.68-0.88). CONCLUSIONS: In patients with endovascularly treated intracranial aneurysms, DISCO-MRA provides superior diagnostic performance in comparison with TOF-MRA in delineating residual aneurysms in a fraction of the time.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Angiografia Digital , Progressão da Doença , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética
5.
AJNR Am J Neuroradiol ; 42(10): 1859-1864, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34446456

RESUMO

BACKGROUND AND PURPOSE: Two-thirds of lymphatic malformations in children are found in the head and neck. Although conventionally managed through surgical resection, percutaneous sclerotherapy has gained popularity. No reproducible grading system has been designed to compare sclerotherapy outcomes on the basis of radiologic findings. We propose an MR imaging-based grading scale to assess the response to sclerotherapy and present an evaluation of its interrater reliability. MATERIALS AND METHODS: A grading system was developed to stratify treatment outcomes on the basis of interval changes observed on MR imaging. By means of this system, 56 consecutive cases from our institution with formally diagnosed head and neck lymphatic malformations treated by sclerotherapy were retrospectively graded. Each patient underwent pre- and posttreatment MR imaging. Each study was evaluated by 3 experienced neuroradiologists. Interrater reliability was assessed using the Krippendorff α statistic, intraclass coefficient, and 2-way Spearman ρ correlation. RESULTS: The overall Krippendorff α statistic was 0.93 (95% CI, 0.89-0.95), denoting excellent agreement among raters. Intraclass coefficients with respect to consistency and absolute agreements were both 0.97 (95% CI, 0.96-0.98), illustrating low variability. Every combination of individual rater pairs demonstrated statistically significant (P < .01) linear Spearman ρ correlations, with values ranging from 0.90 to 0.95. CONCLUSIONS: The proposed radiographic grading scale demonstrates excellent interrater reliability. Adoption of this new scale can standardize reported outcomes following sclerotherapy for head and neck lymphatic malformation and may aid in the investigation of future questions regarding optimal management of these lesions.


Assuntos
Anormalidades Linfáticas , Criança , Cabeça/diagnóstico por imagem , Humanos , Anormalidades Linfáticas/diagnóstico por imagem , Anormalidades Linfáticas/terapia , Pescoço/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Escleroterapia , Resultado do Tratamento
6.
AJNR Am J Neuroradiol ; 41(11): 2027-2033, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33033046

RESUMO

BACKGROUND AND PURPOSE: Developed using a rigorous mathematic framework, Maximum AmbiGuity distance for Phase Imaging (MAGPI) is a promising phase-imaging technique that provides optimal phase SNR and reduced susceptibility artifacts. We aimed to test the potential of MAGPI over routinely used SWI in the detection of traumatic cerebral microbleeds in athletes diagnosed with mild traumatic brain injury. MATERIALS AND METHODS: In this prospective study, 10 athletes (18-22 years of age, 3 women/7 men) diagnosed with mild traumatic brain injury were enrolled. Brain MRIs were performed using 3T MR imaging at 2 days, 2 weeks, and 2 months after head trauma. The imaging protocol included whole-brain T1 MPRAGE, T2 FLAIR, conventional SWI, and the MAGPI multiecho sequence. Phase images from MAGPI were put through a previously described SWI process to generate MAGPI-SWI. Conventional and MAGPI-SWI were assessed independently by a board-certified neuroradiologist for the presence of contusions and cerebral microbleeds. All participants had routine neuropsychological assessment and Visuo-Motor Tests. RESULTS: At initial assessment, 4 of the participants had visuo-motor performance indicative of mild traumatic brain injury, and 4 participants had a Post-Concussion Symptom Scale score of >21, a threshold that has been used to define moderate impairment. Cerebral microbleeds were identified in 6 participants on MAGPI-SWI, 4 of whom had evidence of concurrent contusions on FLAIR imaging. None of these cerebral microbleeds were identified confidently on conventional SWI due to substantial distortion and susceptibility artifacts. CONCLUSIONS: Optimal phase unwrapping with reduced susceptibility in MAGPI-SWI can clarify small microbleeds that can go undetected with routinely used conventional SWI.


Assuntos
Concussão Encefálica/diagnóstico por imagem , Hemorragia Cerebral/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Concussão Encefálica/complicações , Hemorragia Cerebral/etiologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Adulto Jovem
7.
AJNR Am J Neuroradiol ; 41(5): E29, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32241772
8.
AJNR Am J Neuroradiol ; 41(3): 522-528, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32165367

RESUMO

BACKGROUND AND PURPOSE: Our aim was to test the hypothesis that our recently introduced 4D-dynamic contrast-enhanced MR imaging with high spatial and temporal resolution has equivalent accuracy to 4D-CT for preoperative gland localization in primary hyperparathyroidism without requiring exposure to ionizing radiation. MATERIALS AND METHODS: Inclusion criteria were the following: 1) confirmed biochemical diagnosis of primary hyperparathyroidism, 2) preoperative 4D-dynamic contrast-enhanced MR imaging, and 3) surgical cure with >50% decrease in serum parathyroid hormone intraoperatively. 4D-dynamic contrast-enhanced studies were reviewed independently by 2 neuroradiologists to identify the side, quadrant, and number of abnormal glands, and compared with surgical and pathologic results. RESULTS: Fifty-four patients met the inclusion criteria: 37 had single-gland disease, and 17, multigland disease (9 with double-gland hyperplasia; 3 with 3-gland hyperplasia; and 5 with 4-gland hyperplasia). Interobserver agreement (κ) for the side (right versus left) was 0.92 for single-gland disease and 0.70 for multigland disease. Interobserver agreement for the quadrant (superior versus inferior) was 0.70 for single-gland disease and 0.69 for multigland disease. For single-gland disease, the gland was correctly located in 34/37 (92%) patients, with correct identification of the side in 37/37 (100%) and the quadrant in 34/37 (92%) patients. For multigland disease, the glands were correctly located in 35/47 (74%) patients, with correct identification of the side in 35/47 (74%) and the quadrant in 36/47 (77%). CONCLUSIONS: The proposed high spatial and temporal resolution 4D-dynamic contrast-enhanced MR imaging provides excellent diagnostic performance for preoperative localization in primary hyperparathyroidism, with correct gland localization of 92% for single-gland disease and 74% in multigland disease, superior to 4D-CT studies.


Assuntos
Hiperparatireoidismo Primário/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Paratireoidectomia/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Feminino , Humanos , Hiperparatireoidismo Primário/cirurgia , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
AJNR Am J Neuroradiol ; 41(3): 446-448, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32139424

RESUMO

Cerebral amyloid angiopathy is characterized by deposition of amyloid-ß fibrils in the walls of small-to-medium-sized blood vessels. In this retrospective review of 5 patients with histologically confirmed noninflammatory cerebral amyloid angiopathy, high-resolution vessel wall MRI showed arterial wall enhancement in 2 patients (40%). Despite common consensus of equating vessel wall enhancement with inflammation, this report demonstrates that ß-amyloid accumulation alone without inflammation can be associated with arterial wall enhancement in a subset of patients.


Assuntos
Artérias/patologia , Angiopatia Amiloide Cerebral/patologia , Idoso , Peptídeos beta-Amiloides/metabolismo , Artérias/diagnóstico por imagem , Artérias/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Encéfalo/patologia , Angiopatia Amiloide Cerebral/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Retrospectivos
10.
AJNR Am J Neuroradiol ; 40(12): 2033-2038, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31727750

RESUMO

BACKGROUND AND PURPOSE: Automated ASPECTS has the potential of reducing interobserver variability in the determination of early ischemic changes. We aimed to assess the performance of an automated ASPECTS software against the assessment of a neuroradiologist in a comparative analysis with concurrent CTP-based CBV ASPECTS. MATERIALS AND METHODS: Patients with anterior circulation stroke who had baseline NCCT and CTP and underwent successful mechanical thrombectomy were included. NCCT-ASPECTS was assessed by 2 neuroradiologists, and discrepancies were resolved by consensus. CTP-CBV ASPECTS was assessed by a different neuroradiologist. Automated ASPECTS was provided by Brainomix software. ASPECTS was dichotomized (ASPECTS ≥6 or <6) and was also based on the time from onset (>6 or ≤6 hours). RESULTS: A total of 58 patients were included. The interobserver agreement for NCCT ASPECTS was moderate (κ = 0.48) and marginally improved (κ = 0.64) for dichotomized data. Automated ASPECTS showed excellent agreement with consensus reads (κ = 0.84) and CTP-CBV ASPECTS (κ = 0.84). Intraclass correlation coefficients for ASPECTS across all 3 groups were 0.84 (95% CI, 0.76-0.90, raw scores) and 0.94 (95% CI, 0.91-0.96, dichotomized scores). Automated scores were comparable with consensus reads and CTP-CBV ASPECTS in patients when grouped on the basis of time from symptom onset (>6 or ≤6 hours). There was significant (P < .001) negative correlation with final infarction volume and the 3 ASPECTS groups (r = -0.52, consensus reads; -0.58, CTP-CBV; and -0.66, automated). CONCLUSIONS: ASPECTS derived from an automated software performs equally as well as consensus reads of expert neuroradiologists and concurrent CTP-CBV ASPECTS and can be used to standardize ASPECTS reporting and minimize interpretation variability.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Imagem de Perfusão/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Isquemia Encefálica/terapia , Infarto Cerebral/diagnóstico por imagem , Circulação Cerebrovascular , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Software , Acidente Vascular Cerebral/terapia , Trombectomia
11.
AJNR Am J Neuroradiol ; 40(9): 1491-1497, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31413007

RESUMO

BACKGROUND AND PURPOSE: The Bayesian probabilistic method has shown promising results to offset noise-related variability in perfusion analysis. Using CTP, we aimed to find optimal Bayesian-estimated thresholds based on multiparametric voxel-level models to estimate the ischemic core in patients with acute ischemic stroke. MATERIALS AND METHODS: Patients with anterior circulation acute ischemic stroke who had baseline CTP and achieved successful recanalization were included. In a subset of patients, multiparametric voxel-based models were constructed between Bayesian-processed CTP maps and follow-up MRIs to identify pretreatment CTP parameters that were predictive of infarction using robust logistic regression. Subsequently CTP-estimated ischemic core volumes from our Bayesian model were compared against routine clinical practice oscillation singular value decomposition-relative cerebral blood flow <30%, and the volumetric accuracy was assessed against final infarct volume. RESULTS: In the constructed multivariate voxel-based model, 4 variables were identified as independent predictors of infarction: TTP, relative CBF, differential arterial tissue delay, and differential mean transit time. At an optimal cutoff point of 0.109, this model identified infarcted voxels with nearly 80% accuracy. The limits of agreement between CTP-estimated ischemic core and final infarct volume ranged from -25 to 27 mL for the Bayesian model, compared with -61 to 52 mL for oscillation singular value decomposition-relative CBF. CONCLUSIONS: We established thresholds for the Bayesian model to estimate the ischemic core. The described multiparametric Bayesian-based model improved consistency in CTP estimation of the ischemic core compared with the methodology used in current clinical routine.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Imagem de Perfusão/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Teorema de Bayes , Isquemia Encefálica/terapia , Artérias Cerebrais/diagnóstico por imagem , Infarto Cerebral/diagnóstico por imagem , Circulação Cerebrovascular , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/terapia , Trombectomia , Resultado do Tratamento
12.
AJNR Am J Neuroradiol ; 40(5): 769-775, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31000524

RESUMO

BACKGROUND AND PURPOSE: Predicting motor outcome following intracerebral hemorrhage is challenging. We tested whether the combination of clinical scores and DTI-based assessment of corticospinal tract damage within the first 12 hours of symptom onset after intracerebral hemorrhage predicts motor outcome at 3 months. MATERIALS AND METHODS: We prospectively studied patients with motor deficits secondary to primary intracerebral hemorrhage within the first 12 hours of symptom onset. Patients underwent multimodal MR imaging including DTI. We assessed intracerebral hemorrhage and perihematomal edema location and volume, and corticospinal tract involvement. The corticospinal tract was considered affected when the tractogram passed through the intracerebral hemorrhage or/and the perihematomal edema. We also calculated affected corticospinal tract-to-unaffected corticospinal tract ratios for fractional anisotropy, mean diffusivity, and axial and radial diffusivities. Motor impairment was graded by the motor subindex scores of the modified NIHSS. Motor outcome at 3 months was classified as good (modified NIHSS 0-3) or poor (modified NIHSS 4-8). RESULTS: Of 62 patients, 43 were included. At admission, the median NIHSS score was 13 (interquartile range = 8-17), and the median modified NIHSS score was 5 (interquartile range = 2-8). At 3 months, 13 (30.23%) had poor motor outcome. Significant independent predictors of motor outcome were NIHSS and modified NIHSS at admission, posterior limb of the internal capsule involvement by intracerebral hemorrhage at admission, intracerebral hemorrhage volume at admission, 72-hour NIHSS, and 72-hour modified NIHSS. The sensitivity, specificity, and positive and negative predictive values for poor motor outcome at 3 months by a combined modified NIHSS of >6 and posterior limb of the internal capsule involvement in the first 12 hours from symptom onset were 84%, 79%, 65%, and 92%, respectively (area under the curve = 0.89; 95% CI, 0.78-1). CONCLUSIONS: Combined assessment of motor function and posterior limb of the internal capsule damage during acute intracerebral hemorrhage accurately predicts motor outcome.


Assuntos
Hemorragia Cerebral/patologia , Transtornos Motores/etiologia , Tratos Piramidais/patologia , Recuperação de Função Fisiológica , Idoso , Hemorragia Cerebral/complicações , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Tratos Piramidais/diagnóstico por imagem
13.
AJNR Am J Neuroradiol ; 39(6): 1039-1046, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29674411

RESUMO

BACKGROUND AND PURPOSE: Early and accurate identification of tumor progression in patients with low-grade gliomas is challenging. We aimed to assess the role of quantitative ADC analysis in the sequential follow-up of patients with low-grade gliomas as a potential imaging marker of tumor stability or progression. MATERIALS AND METHODS: In this retrospective study, patients with a diagnosis of low-grade glioma with at least 12 months of imaging follow-up were retrospectively reviewed. Two neuroradiologists independently reviewed sequential MR imaging in each patient to determine tumor progression using the Response Assessment in Neuro-Oncology criteria. Normalized mean ADC (ADCmean) and 10th percentile ADC (ADC10) values from FLAIR hyperintense tumor volume were calculated for each MR image and compared between patients with stable disease versus tumor progression using univariate analysis. The interval change of ADC values between sequential scans was used to differentiate stable disease from progression using the Fisher exact test. RESULTS: Twenty-eight of 69 patients who were evaluated met our inclusion criteria. Fifteen patients were classified as stable versus 13 patients as having progression based on consensus reads of MRIs and the Response Assessment in Neuro-Oncology criteria. The interval change of ADC values showed greater concordance with ultimate lesion disposition than quantitative ADC values at a single time point. The interval change in ADC10 matched the expected pattern in 12/13 patients with tumor progression (overall diagnostic accuracy of 86%, P <.001). On average, the ADC10 interval change predicted progression 8 months before conventional MR imaging. CONCLUSIONS: The interval change of ADC10 values can be used to identify progression versus stability of low-grade gliomas with a diagnostic accuracy of 86% and before apparent radiologic progression on conventional MR imaging.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Glioma/diagnóstico por imagem , Glioma/patologia , Adulto , Idoso , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
AJNR Am J Neuroradiol ; 39(2): 219-225, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29217747

RESUMO

BACKGROUND AND PURPOSE: Patients with acute stroke with robust collateral flow have better clinical outcomes and may benefit from endovascular treatment throughout an extended time window. Using a multiparametric approach, we aimed to identify MR perfusion parameters that can represent the extent of collaterals, approximating DSA. MATERIALS AND METHODS: Patients with anterior circulation proximal arterial occlusion who had baseline MR perfusion and DSA were evaluated. The volume of arterial tissue delay (ATD) at thresholds of 2-6 seconds (ATD2-6 seconds) and >6 seconds (ATD>6 seconds) in addition to corresponding values of normalized CBV and CBF was calculated using VOI analysis. The association of MR perfusion parameters and the status of collaterals on DSA were assessed by multivariate analyses. Receiver operating characteristic analysis was performed. RESULTS: Of 108 patients reviewed, 39 met our inclusion criteria. On DSA, 22/39 (56%) patients had good collaterals. Patients with good collaterals had significantly smaller baseline and final infarct volumes, smaller volumes of severe hypoperfusion (ATD>6 seconds), larger volumes of moderate hypoperfusion (ATD2-6 seconds), and higher relative CBF and relative CBV values than patients with insufficient collaterals. Combining the 2 parameters into a Perfusion Collateral Index (volume of ATD2-6 seconds × relative CBV2-6 seconds) yielded the highest accuracy for predicting collateral status: At a threshold of 61.7, this index identified 15/17 (88%) patients with insufficient collaterals and 22/22 (100%) patients with good collaterals, for an overall accuracy of 94.1%. CONCLUSIONS: The Perfusion Collateral Index can predict the baseline collateral status with 94% diagnostic accuracy compared with DSA.


Assuntos
Circulação Colateral/fisiologia , Imageamento por Ressonância Magnética/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Artérias/diagnóstico por imagem , Isquemia Encefálica/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Perfusão , Curva ROC , Acidente Vascular Cerebral/terapia
15.
AJNR Am J Neuroradiol ; 36(11): 2147-52, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26359150

RESUMO

BACKGROUND AND PURPOSE: The hypervascular nature of parathyroid adenomas can be explored by proper dynamic imaging to narrow the target lesions for surgical exploration. The purpose of this study was to establish MR perfusion characteristics of parathyroid adenomas to differentiate them from their mimics, such as subjacent thyroid tissue and cervical lymph nodes. MATERIALS AND METHODS: Preoperative high-spatial and -temporal resolution dynamic 4D contrast-enhanced MR imaging in 30 patients with surgically proved parathyroid adenomas was evaluated retrospectively. Using coregistered images, we placed ROIs over the parathyroid adenoma, thyroid gland, and a cervical lymph node (jugulodigastric) to obtain peak enhancement, time-to-peak, wash-in, and washout in each patient. Data were analyzed by logistic regression and analysis of variance. Receiver operating characteristic analysis was performed to determine the optimal parameters for determination of parathyroid adenomas versus thyroid tissue and cervical lymph nodes. RESULTS: Parathyroid adenomas showed significantly (P < .05) faster time-to-peak, higher wash-in, and higher washout compared with cervical lymph nodes and significantly (P < .05) higher peak enhancement, faster time-to-peak, higher wash-in, and higher washout compared with thyroid tissue. Logistic regression analysis indicated significant contribution from time-to-peak (P = .02), wash-in (P = .03), and washout (P = .008) for differentiation of parathyroid adenomas from thyroid and cervical lymph nodes. Using receiver operating characteristic analysis, we obtained the best diagnostic accuracy from a combination of time-to-peak/wash-in/washout in the differentiation of parathyroid adenomas versus lymph nodes (area under the curve, 0.96; sensitivity/specificity, 88%/90%) and in distinguishing parathyroid adenomas versus thyroid tissue (area under the curve, 0.96; sensitivity/specificity, 91%/95%). CONCLUSIONS: Dynamic 4D contrast-enhanced MR imaging can be used to exploit the hypervascular nature of parathyroid adenomas. Multiparametric MR perfusion can distinguish parathyroid adenomas from subjacent thyroid tissue or lymph nodes with diagnostic accuracies of 96%.


Assuntos
Adenoma/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias das Paratireoides/patologia , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
AJNR Am J Neuroradiol ; 36(4): 710-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25430859

RESUMO

BACKGROUND AND PURPOSE: DSC perfusion has been increasingly used in conjunction with other contrast-enhanced MR applications and therefore there is need for contrast-dose reduction when feasible. The purpose of this study was to establish the feasibility of reduced-contrast-dose brain DSC perfusion by using a probabilistic Bayesian method and to compare the results with the commonly used singular value decomposition technique. MATERIALS AND METHODS: Half-dose (0.05-mmol/kg) and full-dose (0.1-mmol/kg) DSC perfusion studies were prospectively performed in 20 patients (12 men; 34-70 years of age) by using a 3T MR imaging scanner and a gradient-EPI sequence (TR/TE, 1450/22 ms; flip angle, 90°). All DSC scans were processed with block circulant singular value decomposition and Bayesian probabilistic methods. SNR analysis was performed in both half-dose and full-dose groups. The CBF, CBV, and MTT maps from both full-dose and half-dose scans were evaluated qualitatively and quantitatively in both WM and GM on coregistered perfusion maps. Statistical analysis was performed by using a t test, regression, and Bland-Altman analysis. RESULTS: The SNR was significantly (P < .0001) lower in the half-dose group with 32% and 40% reduction in GM and WM, respectively. In the half-dose group, the image-quality scores were significantly higher in Bayesian-derived CBV (P = .02) and MTT (P = .004) maps in comparison with block circulant singular value decomposition. Quantitative values of CBF, CBV, and MTT in Bayesian-processed data were comparable and without a statistically significant difference between the half-dose and full-dose groups. The block circulant singular value decomposition-derived half-dose perfusion values were significantly different from those of the full-dose group both in GM (CBF, P < .001; CBV, P = .02; MTT, P = .02) and WM (CBF, P < .001; CBV, P = .003; MTT, P = .01). CONCLUSIONS: Reduced-contrast-dose (0.05-mmol/kg) DSC perfusion of the brain is feasible at 3T by using the Bayesian probabilistic method with quantitative results comparable with those of the full-dose protocol.


Assuntos
Teorema de Bayes , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular/fisiologia , Meios de Contraste/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
17.
Case Rep Pediatr ; 2014: 792925, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25405050

RESUMO

Pediatric soft tissue sarcomas account for approximately 10% of all pediatric malignancies. Malignant ectomesenchymoma is rare biphasic sarcomas consisting of both mesenchymal and neuroectodermal elements. Approximately 64 cases have been reported in the literature and are believed to arise from pluripotent embryologic migratory neural crest cells. We report a 4-year-old boy who initially presented with a pelvic mass and inguinal lymphadenopathy at 6 months of age. Inguinal lymph node biopsy revealed a distinct biphasic tumor with microscopic and immunophenotypic characteristics diagnostic for both alveolar rhabdomyosarcoma and poorly differentiated neuroblastoma. The patient received national protocol chemotherapy against rhabdomyosarcoma with good response and presented with a cerebellar mass 21 months later. The metastatic tumor revealed sheets of primitive tumor cells and diagnostic areas of rhabdomyosarcoma and neuroblastoma were identified only by immunohistochemistry. Cytogenetic analysis of metastatic tumor demonstrated complex karyotype with multiple chromosomal deletions and duplications. The patient received national protocol chemotherapy against neuroblastoma and adjuvant radiotherapy after surgical resection of the cerebellar tumor with good response. He is currently off from any treatment for 18 months with no evidence of tumor recurrence or metastasis.

18.
AJNR Am J Neuroradiol ; 35(6): 1078-84, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24503557

RESUMO

BACKGROUND AND PURPOSE: There is need to improve image acquisition speed for MR imaging in evaluation of patients with acute ischemic stroke. The purpose of this study was to evaluate the feasibility of a 3T MR stroke protocol that combines low-dose contrast-enhanced MRA and dynamic susceptibility contrast perfusion, without additional contrast. METHODS: Thirty patients with acute stroke who underwent 3T MR imaging followed by DSA were retrospectively enrolled. TOF-MRA of the neck and brain and 3D contrast-enhanced MRA of the craniocervical arteries were obtained. A total of 0.1 mmol/kg of gadolinium was used for both contrast-enhanced MRA (0.05 mmol/kg) and dynamic susceptibility contrast perfusion (0.05 mmol/kg) (referred to as half-dose). An age-matched control stroke population underwent TOF-MRA and full-dose (0.1 mmol/kg) dynamic susceptibility contrast perfusion. The cervicocranial arteries were divided into 25 segments. Degree of arterial stenosis on contrast-enhanced MRA and TOF-MRA was compared with DSA. Time-to-maximum maps (>6 seconds) were evaluated for image quality and hypoperfusion. Quantitative analysis of arterial input function curves, SNR, and maximum T2* effects were compared between half- and full-dose groups. RESULTS: The intermodality agreements (k) for arterial stenosis were 0.89 for DSA/contrast-enhanced MRA and 0.63 for DSA/TOF-MRA. Detection specificity of >50% arterial stenosis was lower for TOF-MRA (89%) versus contrast-enhanced MRA (97%) as the result of overestimation of 10% (39/410) of segments by TOF-MRA. The DWI-perfusion mismatch was identified in both groups with high interobserver agreement (r = 1). There was no significant difference between full width at half maximum of the arterial input function curves (P = .14) or the SNR values (0.6) between the half-dose and full-dose groups. CONCLUSIONS: In patients with acute stroke, combined low-dose contrast-enhanced MRA and dynamic susceptibility contrast perfusion at 3T is feasible and results in significant scan time and contrast dose reductions.


Assuntos
Isquemia Encefálica/patologia , Artérias Cerebrais/patologia , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Proteção Radiológica/métodos , Acidente Vascular Cerebral/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Isquemia Encefálica/complicações , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Compostos Organometálicos/administração & dosagem , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Acidente Vascular Cerebral/etiologia , Fatores de Tempo
19.
AJNR Am J Neuroradiol ; 35(5): 878-83, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24335543

RESUMO

BACKGROUND AND PURPOSE: Further improvement in acquisition speed is needed, if MR imaging is to compete with CT for evaluation of patients with acute ischemic stroke. The purpose of this study was to evaluate the feasibility of implementing an echo-planar fluid-attenuated inversion recovery (EPI-FLAIR) sequence into an acute MR stroke protocol with potential reduction in scan time and to compare the results with conventional FLAIR images. MATERIALS AND METHODS: Fifty-two patients (28 men and 24 women; age range, 32-96 years) with acute ischemic stroke were prospectively evaluated with an acute stroke MR protocol, which included both conventional FLAIR and EPI-FLAIR imaging with integration of parallel acquisition. The image acquisition time was 52 seconds for EPI-FLAIR and 3 minutes for conventional FLAIR. FLAIR and EPI-FLAIR studies were assessed by 2 observers independently for image quality and conspicuity of hyperintensity in correlation with DWI and were rated as concordant or discordant. Coregistered FLAIR and EPI-FLAIR images were evaluated for signal intensity ratio of the DWI-positive lesion to contralateral normal white matter. RESULTS: An estimated 96% of all FLAIR and EPI-FLAIR studies were rated of diagnostic image quality by both observers, with interobserver agreements of κ = 0.82 and κ = 0.63 for FLAIR and EPI-FLAIR, respectively. In 36 (95%) of 38 patients with acute infarction, FLAIR and EPI-FLAIR were rated concordant regarding DWI lesion. The mean ± standard deviation of the signal intensity ratio values on EPI-FLAIR and FLAIR for DWI-positive lesions were 1.28 ± 0.16 and 1.25 ± 0.17, respectively (P = .47), and demonstrated significant correlation (r = 0.899, z value = 8.677, P < .0001). CONCLUSIONS: In patients with acute stroke, EPI-FLAIR is feasible with comparable qualitative and quantitative results to conventional FLAIR and results in reduced acquisition time.


Assuntos
Isquemia Encefálica/patologia , Encéfalo/patologia , Imagem de Tensor de Difusão/métodos , Imagem Ecoplanar/métodos , Acidente Vascular Cerebral/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/complicações , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Acidente Vascular Cerebral/etiologia
20.
AJNR Am J Neuroradiol ; 30(1): 46-52, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18842763

RESUMO

BACKGROUND AND PURPOSE: High-resolution contrast-enhanced MR angiography (CE-MRA) acquired at 3T exquisitely depict carotid artery (CA) stenosis. In this study, we examined the agreement of different vessel-analysis tools with manual quantitative measurement by 2 readers using CE-MRA data. MATERIALS AND METHODS: Three vessel tools determining the trajectory of the vessel of interest and, subsequently, the vessel dimensions were tested against manual measurements. Diameter and area stenoses were calculated. CE-MRA data of 32 patients with CA stenosis were evaluated. The agreement between different measurements was assessed with kappa statistics after categorizing stenosis (<25%, 25%-49%, 50%-69%, 70%-99%, and 100%). RESULTS: The mean grades of stenosis based on diameter measurements were 59% (readers) and 60%/56%/59% based on the analysis with tools A/B/C (P = 0.2-0.7). kappa values for agreement between readers and the vessel tools were 0.73/0.77/0.77 (tools A/B/C for all CAs) and 0.66/0.74/0.75 (for the symptomatic side). The mean grades of stenoses based on area measurements for tools A/B/C were 68%/63%/69% versus 58% for readers. Values from readers differed significantly from those for tools A and C (P < 0.01). kappa values for agreement between readers and the vessel tools were 0.66/0.55/0.64 (for all CAs) and 0.53/0.44/0.57 (for the symptomatic side). CONCLUSIONS: The automated approach allows accurate assessment of vessel dimensions in MRA images at least for diameter measurements according to the North American Symptomatic Carotid Endarterectomy Trial criteria.


Assuntos
Algoritmos , Artérias Carótidas/patologia , Estenose das Carótidas/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Adulto , Idoso , Inteligência Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...