1.
J Hand Ther ; 19(3): 299-305; quiz 306, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16861129

RESUMO

PURPOSE: To determine whether current perception threshold (CPT) varied between subjects with and without carpal tunnel syndrome (CTS) and whether positioning in wrist extension (reversed Phalen's test) was provocative. METHOD: Subjects (n=30) were tested using the Neurometer (Neutron, Inc., Baltimore, MD) at 5, 250, and 2,000 Hz in a rest and reverse Phalen's position. Group and positional differences were analyzed using analysis of variance. RESULTS: Higher CPT occurred at 2,000 Hz in both rest (p=0.02) and reverse Phalen's position (p=0.01) in CTS subjects. There was also a significant change in CPT in the CTS group following wrist extension, particularly at 2,000 Hz (p<0.05). CONCLUSION: A positional effect on sensibility was noted at 2,000 Hz in subjects with CTS. Further evaluation is required to determine the role and optimal test protocols for provocative-sensory testing in diagnosis and outcome assessment of CTS. For CPT these should focus on using the 2,000 Hz frequency.


Assuntos
Síndrome do Túnel Carpal/fisiopatologia , Movimento/fisiologia , Limiar Sensorial/fisiologia , Articulação do Punho/fisiopatologia , Adulto , Estudos de Casos e Controles , Estimulação Elétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Condução Nervosa/fisiologia , Projetos Piloto , Estudos Prospectivos , Índice de Gravidade de Doença