Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 66(5): 722-729, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37516380

RESUMO

OBJECTIVE: Poor below knee (BTK) runoff is a predictor of stent failure after endovascular femoropopliteal artery treatment; however, lack of pathological evaluation has prevented characterisation of stent failure. The study aimed to investigate the impact of poor BTK runoff and the antithrombotic effect of the polymer of fluoropolymer coated paclitaxel eluting stents (FP-PESs) in a healthy swine femoropopliteal artery model. METHODS: FP-PESs and bare metal stents (BMSs) and FP-PES and polymer free paclitaxel coated stents (PF-PCSs) were implanted in the bilateral femoral arteries of healthy swine (n = 6, respectively) following coil embolisation in both tibial arteries to induce poor BTK runoff. Histological assessment and intravascular imaging device evaluation were performed at one month. The Japanese Association for Laboratory Animal Science approved the study protocol (reference number: IVT22-90). RESULTS: Optical coherence tomography showed significantly lower percent area stenosis in FP-PES compared with BMS (37.3%, [interquartile range (IQR), 25.6 - 54.3] % vs. 92.5% [IQR, 75.5 - 96.1] %, respectively, p = .031), and PF-PCS (8.3% [IQR, 4.5 - 27.0] % vs. 31.2% [IQR, 23.3 - 52.2] %, respectively, p = .031). Histopathological evaluation demonstrated that thin fibrin attachment without re-stenosis was the most dominant neointimal tissue characteristic in FP-PES. On the other hand, neointimal tissue characteristics with significant restenosis of BMS and PF-PCS were mainly organising or organised thrombus. CONCLUSION: Organising and or organised thrombus attachment due to poor BTK runoff was the main cause of in stent restenosis of the swine femoral artery. FP-PES demonstrated the least percent area stenosis, suggesting the importance of the antithrombotic effect of polymer.


Assuntos
Stents Farmacológicos , Trombose , Suínos , Animais , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Polímeros de Fluorcarboneto , Fibrinolíticos , Constrição Patológica , Stents , Polímeros , Paclitaxel , Neointima , Trombose/etiologia , Resultado do Tratamento
2.
Cardiovasc Interv Ther ; 38(2): 223-230, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36609899

RESUMO

BACKGROUND: Excimer laser is used to treat coronary artery disease, especially in case of lesions with thrombus and in-stent restenosis (ISR). However, there are no in vivo preclinical studies that have evaluated the pathological reactions of the vessel wall after excimer laser ablation. METHODS: Bare-metal stents were placed in the external iliac arteries of six healthy rabbits. Twenty-eight days later, excimer laser ablation was performed with low-power (45 (fluency)/25 (rate)) in one side, and high-power (60/40) in the opposite side, followed by optical coherence tomography (OCT) evaluation. Rabbits were sacrificed 15 min after the procedure, and histological assessment was performed. RESULTS: Morphometry analysis of OCT showed similar stent and lumen size between low-power and high-power group. Histological evaluation suggested endothelial cell loss, fibrin deposition, and tissue loss. The low-power group showed significantly less pathological changes compared with the high-power group: angle of endothelial cell loss, 32.4° vs. 191.7° (interquartile range, 8.8°-131.7° vs. 125.7°-279.5°; p < 0.01); fibrin deposition, 1.1° vs. 59.6° (0.0°-70.4° vs. 31.4°-178.4°; p = 0.03); and tissue loss 0.0° vs. 18.2° (0.0°-8.7° vs. 0.0°-42.7°; p = 0.03). CONCLUSIONS: The pathological changes in neointima were more prominent after high-power excimer laser ablation than after low-power excimer laser. To improve safety in clinical practice, understanding the pathological changes of tissues after excimer laser in lesions with ISR is essential.


Assuntos
Angioplastia a Laser , Reestenose Coronária , Animais , Humanos , Coelhos , Neointima/patologia , Lasers de Excimer/uso terapêutico , Artéria Ilíaca/cirurgia , Angiografia Coronária , Stents/efeitos adversos , Fibrina , Tomografia de Coerência Óptica/métodos , Reestenose Coronária/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS