Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Med Surg (Lond) ; 76: 103573, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35495371

RESUMO

Background: Post-extubation-atelectasis (PEA) is a common problem after the removal of an endotracheal tube in neonates which increases the rate of extubation failure. Different techniques have been introduced for the prevention of PEA. One technique is the removal of the endotracheal tube by negative or positive gradients of pressure. No RCT has yet been done to compare the use of these two methods in neonates. So this study aimed to compare the role of positive and negative pressure during extubation of neonates on the prevention of PEA. Materials and methods: We enrolled 100 newborns in this RCT that required at least 24 h of mechanical ventilation. The endotracheal tube in one group was removed by a T-Piece resuscitator at a PEEP level of 5 CmH2o while in another group extubation was done applying suction pressure of 100 mmHg by random selection. Prevalence of PEA in CXRs after extubation was compared between the two groups. Results: The prevalence of PEA in the extubation of the positive pressure group (24%) was significantly lower than that of the negative pressure group (46%) (p = 0.024). Extubation failure was found to be lower in the positive pressure group (6% versus 20% P = 0.037). No significant difference was observed between the two groups in the prevalence of apnea, pneumothorax, and death at 3 days after extubation. Conclusion: The use of positive pressure during removal of the endotracheal tube in newborn infants reduced the rate of PEA compared with the negative pressure so extubation by a positive pressure is recommended in neonates.

2.
Indian J Pharmacol ; 53(2): 108-114, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34100394

RESUMO

OBJECTIVES: Despite extensive caffeine use in preterm infants, the pharmacokinetics (PKs) data are limited because of the studies are complicated to do in these patients. This research was investigated the PK profile of two various dosages of caffeine in premature neonates. MATERIALS AND METHODS: The PK values of caffeine in premature neonates with Apnea were predicted by using all of computer-based simulation (Simcyp®), population-based PK, and modeling (P-Pharm®). We assayed the plasma levels of caffeine in two groups. The information was analyzed utilizing nonlinear mixed-effects modeling approach. The PK parameters were assessed simulating virtual clinical considers with subjects got 20 mg. kg-1 of caffeine in both groups, which was followed by a 5 mg. kg-1 once daily in Group 1 or 2.5 mg. kg-1 twice daily in Group 2. All statistical analysis was executed utilizing SSPS issue 19 and a P value of 0.05 was chosen significance. RESULTS: In the present study, the means CL, volume of distribution, and T1/2 of caffeine in preterm infants were 0.0476 L. h-1, 1.1081 L, 16.2284 h, respectively. Whereas our simulated means by Simcyp were 0.090 L. h-1, 1.841 L, and 14.653 h in Group 1 and 16.223 h in Group 2, respectively. CONCLUSIONS: There was overall good agreement between predicted and measured PK values in our study. This study provides an initial demonstration of Simcyp simulation advantage on anticipating of PK parameters.


Assuntos
Apneia/tratamento farmacológico , Cafeína/farmacocinética , Recém-Nascido Prematuro/metabolismo , Apneia/metabolismo , Cafeína/administração & dosagem , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Modelos Biológicos
3.
Caspian J Intern Med ; 9(1): 46-53, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29387319

RESUMO

BACKGROUND: Caffeine is widely used for prevention of apnea and helps successful extubation from mechanical ventilation. It facilitates the transition from invasive to noninvasive support and reduces duration of continuous positive airway pressure (CPAP) in preterm infants. The optimum caffeine dose in preterm infants has not been well-studied in terms of benefits and risks. We compared efficacy and safety of once versus twice-daily caffeine dose in premature infants. METHODS: This study was a randomized clinical trial conducted in Bu-Ali Sina Teaching Hospital, Sari. Patients with gestational age of <37 weeks were included. Both groups received 20 mg/kg loading dose of caffeine intravenously followed by maintenance dose of 5 mg/kg/day in group 1 or 2.5 mg/kg every 12 hours in group 2. Extubation failure, CPAP failure and possibly adverse reactions were evaluated. RESULTS: The mean of gestational age and birth weight were 32.27±3.23 (weeks) and 1824.5±702.54 (gr), respectively. The rate of extubation and CPAP failure and length of NICU stay were lower in twice-daily-group with no statistically significant difference. The means of O2 saturations on the first three days of caffeine therapy were higher in twice-daily-group. Caffeine was generally safe and well tolerated. CONCLUSIONS: This study, which assayed short-term effects of caffeine, showed that twice daily caffeine maintenance dose was related to more benefits in facilitating extubation or prevention of CPAP failure in preterm infants. However, there was not statistically significant difference between two groups.

4.
Iran Biomed J ; 21(3): 182-9, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27869251

RESUMO

BACKGROUND: Phototherapy is believed to be a safe method for the management of hyperbilirubinemia. However, there are some controversial issues regarding the genotoxic effects of phototherapy on DNA. The aim of this study was to investigate morphologically both phototherapy-induced DNA double-strand breaks (DSBs) and apoptosis in lymphocytes derived from jaundiced and non-jaundiced neonates. METHODS: Newborns were divided into three groups, including phototherapy-treated (PT, n=30) jaundiced newborns with total serum bilirubin (TSB) levels >15 mg/dl, non-treated jaundiced newborns (C+, n=27), as positive, as well as healthy negative (C-, n=30) controls with TSB levels ranging from 10 and 15 mg/dl and less than 5 mg/dl, respectively. Lymphocytes were isolated from whole blood samples by Ficoll-isopaque density gradient centrifugation and then assessed for DNA damage and apoptosis before and 24 hours after incubation at 37°C in 5% CO2 using the neutral comet assay. RESULTS: DSB levels were significantly much higher in the PT group compared to the controls before incubation but decreased remarkably after the incubation period. As expected, no statistical differences were found between the two control groups before and after incubations. The frequency of apoptotic cells showed no significant differences among all the three groups before incubation; however, it was significantly increased in the PT group after incubation. CONCLUSION: It seems that phototherapy in jaundiced infants is able not only to induce apoptosis in newborn lymphocytes but also to affect indirectly DNA integrity.


Assuntos
Dano ao DNA , Hiperbilirrubinemia/patologia , Hiperbilirrubinemia/terapia , Linfócitos/patologia , Mutagênicos/toxicidade , Fototerapia , Apoptose/efeitos dos fármacos , Contagem de Células , Demografia , Feminino , Humanos , Recém-Nascido , Linfócitos/efeitos dos fármacos , Masculino
5.
Iran J Child Neurol ; 9(4): 41-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26664440

RESUMO

OBJECTIVE: Prevalence of neonatal stroke has been reported 1/2300-1/4000 live births and accounts for 12-20% of the cases of neonatal seizures. Although stroke has been introduced as the second cause of the neonatal seizures in literatures, it may remain unclear in diagnostic evaluations of seizure in neonates. This study was performed to assess the prevalence of stroke in neonates with seizure. MATERIALS & METHODS: In this cross-sectional study, all neonates ≥ 28 weeks of gestation with a diagnosis of seizures admitted to the NICU of Boo-Ali Sina Hospital in Sari, north of Iran, were enrolled. Brain CT scan and a Transcranial Doppler ultrasonography were performed for the all cases. In cases that stroke were reported in one or two above modalities, an MRI was also performed and prevalence of stroke was reported. Putative risk factors of stroke were analyzed with univariate and multivariate statistical methods. RESULTS: From 174 newborn infants, 75.3% of neonates were male. Prevalence of stroke was 8%, 2.3% and 3.4% in Doppler ultrasonography, CT scan and MRI reports respectively. Umbilical venous catheterization was the risk factor of stroke in the univariate and multivariate analysis (P= 0.001; OR, 10.39; 95% CI, 2.72- 39.77). The most common form of seizure was focal clonic seizures (78.6%) in neonates with stroke. CONCLUSION: Investigation of stroke as an etiology of neonatal seizures is essential because seizure may be the only symptom of neonatal cerebral infarction. Doppler ultrasonography can be a valuable diagnostic tool at first in critically ill neonates or in situations that MRI is not available primarily. Further studies with notice to outcome assessment of these infants recommended.

6.
Glob J Health Sci ; 8(2): 240-7, 2015 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-26383214

RESUMO

BACKGROUND: Pressure Support Ventilation (PSV) is one of the modes of mechanical ventilation that can be used alone as a weaning strategy in neonates. However, studies on the appropriate pressure level for this mode in neonates are limited. OBJECTIVES: Because the use of adequate pressure support in this mode, keeping the appropriate neonate's tidal volume, and preventing the respiratory complications, this study was aimed to compare extubation failure in the two levels of pressure support ventilation of 10 and 14 cmH2O when removing the neonates from the ventilator. MATERIALS & METHODS: In this randomized clinical trial 50 premature infants of 27-37 weeks with respiratory distress syndrome (RDS) were under mechanical ventilation for at least 48 hours, were randomly assigned to two groups. One group was extubated in PSV mode with pressure of 14 cmH2O and the other with 10 cmH2O. Extubation failure rate and complications such as pneumothorax, death and respiratory parameters were compared in the two groups. RESULTS: Twenty five neonates in each group were assessed. Weaning time, extubation failure rate, and mean airway pressure was lesser in PSV of 10 cmH2O group than Level of 14 cmH2O and those differences were statistically significant (P<0.05). Difference between work of breathing, ventilation time, pneumothorax and mortality rate between two groups were not statistically significant (P>0.05). CONCLUSION: The results of our study show that extubation of the neonates using 10 CmH2O in PSV mode increases the success rate of extubation. Although when Volume- assured PSV can be used, it is more logical to use it for guaranteeing tidal volume, but using the appropriate level of pressure support when the PSV mode is used alone is inevitable and further studies are necessary to demonstrate the level of pressure in this mode.


Assuntos
Respiração com Pressão Positiva/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Desmame do Respirador , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Masculino , Síndrome do Desconforto Respiratório do Recém-Nascido/mortalidade , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Testes de Função Respiratória , Falha de Tratamento
7.
Pediatr Neonatol ; 56(2): 88-94, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25264154

RESUMO

BACKGROUND: Studies on early surfactant administration during nasal continuous positive airway pressure (NCPAP) [intubate-surfactant-extubate (INSURE)] have used continuous positive airway pressure and INSURE in the first hours after birth, but in many centers patients are transported from far away hospitals, reaching the center at a later time. The aim of this study was to compare the effect of INSURE with only NCPAP in the management of respiratory distress syndrome (RDS) in an outborn hospital. METHODS: This study was a controlled randomized clinical trial on 60 neonates who were transported to the neonatal intensive care unit of Boo-Ali Sina Hospital. Neonates born at 27(0)/7 to 34(6)/7 weeks of gestation, aged ≤12 hours, and diagnosed with RDS were placed on NCPAP and then randomly assigned to INSURE or NCPAP alone. The primary outcome was the need for intubation and mechanical ventilation on the basis of the criteria defined by us, and the secondary outcomes were neonatal mortality and other complications of RDS. RESULTS: In 13 months, 60 eligible neonates were enrolled. Our participants in INSURE group received surfactant at the mean age of 5.1 hours. The relative risk of need for mechanical ventilation was 0.55 (95% confidence interval: 0.15-1.9, p = 0.53), and the rate of mortality or other complications of RDS was statistically similar between the two groups. CONCLUSION: After the first few hours of life (mean age of 5.1 hours), the rate of mortality and chronic lung disease and the need for mechanical ventilation were not statistically different between patients receiving INSURE and those in receipt of NCPAP alone.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório do Recém-Nascido/complicações , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Masculino , Respiração Artificial , Síndrome do Desconforto Respiratório do Recém-Nascido/diagnóstico , Resultado do Tratamento
8.
ScientificWorldJournal ; 2014: 946924, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24587764

RESUMO

This study was performed to compare the levels of pain experienced by young infants undergoing either suprapubic aspiration (SPA) or transurethral catheterization (TUC) for the collection of sterile urine samples. This prospective randomized clinical trial was conducted in hospitalized neonates in a university-affiliated hospital. Patients who required urine cultures were randomly assigned into one of two groups, the SPA or TUC group. The infants' faces were videotaped, and the changes in the facial expression and physiological parameters during the procedure were scored using the Premature Infant Pain Profile (PIPP) in a blind manner. The primary outcome was the severity of the pain experienced during each procedure, and the secondary outcomes were the success rate, the duration, and the complications of each procedure. Ninety-four percent of male infants in the TUC group and 77.3% in the SPA group were uncircumcised (P = 0.1). The mean (SD) of the PIPP pain scores did not differ between groups (9.95 ± 3.7 in SPA and 9.64 ± 3.2 in TUC, P = 0.6). The duration of TUC was longer. Both methods can be used to collect urine from neonates, but the difficulty of performing TUC on females and uncircumcised males should be considered.


Assuntos
Biópsia por Agulha Fina/efeitos adversos , Dor/etiologia , Bexiga Urinária/cirurgia , Cateterismo Urinário/efeitos adversos , Coleta de Urina/métodos , Expressão Facial , Feminino , Humanos , Recém-Nascido , Masculino , Medição da Dor/métodos , Estudos Prospectivos , Coleta de Urina/efeitos adversos
9.
J Chromatogr A ; 1078(1-2): 120-7, 2005 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-16007989

RESUMO

A simple and sensitive method for determining anatoxin-a in aqueous samples was developed using solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC-MS) detection. Three forms of polyaniline (PANI) films and a single form of polypyrrole (PPY) film were prepared and applied for SPME. The extraction properties of these films to anatoxin-a were examined and it was shown that leucoemeraldine form of PANI displayed a better selectivity to this compound. SPME conditions were optimized by selecting the appropriate extraction parameters, including type of coating (leucoemeraldine form of PANI at 32 microm thicknesses), salt concentration (10%, w/v), time of extraction (30 min) and stirring rate (1000 rpm). The calibration curve was linear in the range from 50 to 10,000 ng/ml, with the detection limit (S/N = 3) of 11.2 ng/ml. This method was successfully applied for the analysis of anatoxin-a in the cultured media of two species of cyanobacteria.


Assuntos
Compostos de Anilina/química , Toxinas Bacterianas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Toxinas Marinhas/análise , Toxinas de Cianobactérias , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Microquímica , Microcistinas , Polímeros/química , Pirróis/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tropanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...