Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Injury ; 50 Suppl 2: S12-S17, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30745125

RESUMO

PURPOSE: Shoulder instability and reduced range of motion are two common complications of a total reverse shoulder arthroplasty. In this work, a new approach is proposed to estimate how the glenoid component positioning can influence the stability and the range of motion of a reverse shoulder prosthesis. MATERIALS AND METHODS: A standard reverse shoulder prosthesis has been analysed. To perform virtual simulation of the shoulder-prosthesis assembly, all the components of the prosthesis have been acquired via a 3D laser scanner and the solid models of the shoulder bones have been reconstructed through CT images. Loads on the shoulder joint have been estimated using anatomical models database. A new virtual/numerical procedure has been implemented using a 3D parametric modelling software to find the optimal position of the glenosphere. RESULTS: Several analyses have been performed using different configurations obtained by changing the glenoid component tilt and the lateral position of the glenosphere, modified through the insertion of a cylindrical spacer. For the analysed case study, it was found that the interposition of a spacer (between the baseplate and the glenoid) and 15° inferior tilt of the glenosphere allow improving the range of motion and the stability of the shoulder. CONCLUSIONS: Some common complications of the reverse shoulder arthroplasty could be effectively reduced by a suitable positioning of the prosthesis components. In this work, using a new method based on virtual simulations, the influence of the glenosphere positioning has been investigated. An optimal configuration for the analysed case study has been found. The proposed approach could be used to find, with no in vivo experiments, the optimal position of a reverse shoulder prosthesis depending on the different dimensions and shape of the bones of each patient.


Assuntos
Instabilidade Articular/diagnóstico por imagem , Amplitude de Movimento Articular/fisiologia , Luxação do Ombro/cirurgia , Síndrome de Colisão do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Prótese de Ombro , Tomografia Computadorizada por Raios X , Artroplastia do Ombro/métodos , Estudos de Casos e Controles , Guias como Assunto , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Desenho de Prótese , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/cirurgia
2.
Musculoskelet Surg ; 98(2): 135-42, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23719768

RESUMO

INTRODUCTION: Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. PURPOSE: The main goal of the present work is to study the effect of the positioning of the humeral component on the intrinsic stability of the reverse shoulder prosthesis. In particular, through finite element method simulations, the variation of the stability ratio of the shoulder joint has been calculated for both vertical and horizontal dislocating loads depending on the humeral stem version angle. Moreover, in order to estimate the wear of the polyethylene cup, some analyses have been developed to calculate the pressures on the polyethylene insert. RESULTS: The obtained results demonstrate the dislocation of a shoulder prosthesis and the wear of the polyethylene insert can be prevented or limited by conveniently varying the version angle of the humeral component.


Assuntos
Artroplastia de Substituição/métodos , Articulação do Ombro/cirurgia , Humanos , Úmero , Desenho de Prótese
3.
Clin Ter ; 146(11): 675-82, 1995 Nov.
Artigo em Italiano | MEDLINE | ID: mdl-8720344

RESUMO

The authors report 4 cases of Tietze's syndrome. In 3 of them the syndrome onset during a rheumatic disease (psoriatic arthritis, sternoclavicular hyperostosis). It is thus necessary to distinguish between the idiopathic of unknown ethiology and the secondary form due to, a well defined disease, in 3 cases observed.


Assuntos
Artrite Psoriásica/complicações , Hiperostose Esternocostoclavicular/complicações , Síndrome de Tietze , Adulto , Idoso , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome de Tietze/diagnóstico por imagem , Síndrome de Tietze/etiologia , Síndrome de Tietze/patologia , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...