Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthodont Res ; 68(2): 273-282, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37245959

RESUMO

Purpose This study aimed to determine the surface glazing effect on the mechanical and biological properties of three-dimensional printed dental permanent resins.Methods Specimens were prepared using Formlabs, Graphy Tera Harz permanent, and NextDent C&B temporary crown resins. Specimens were divided into three groups: samples with untreated surfaces, glazed surfaces, and sand-glazed surfaces. The flexural strength, Vickers hardness, color stability, and surface roughness of the samples were analyzed to identify their mechanical properties. Their cell viability and protein adsorption were analyzed to identify their biological properties.Results The flexural strength and Vickers hardness of the samples with sand glazed and glazed surfaces were significantly increased. The color change was higher for surface untreated samples than that for the samples with sand-glazed and glazed surfaces. The surface roughness of the samples with sand-glazed and glazed surfaces was low. The samples with sand-glazed and glazed surfaces have low protein adsorption ability and high cell viability.Conclusions Surface glazing increased the mechanical strength, color stability, and cell compatibility, while reducing the Ra and protein adsorption of 3D-printed dental resins. Thus, a glazed surface exhibited a positive effect on the mechanical and biological properties of 3D-printed resins.


Assuntos
Impressão Tridimensional , Areia , Teste de Materiais , Propriedades de Superfície , Resinas Sintéticas , Materiais Dentários
2.
J Prosthodont Res ; 67(1): 121-131, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35570000

RESUMO

PURPOSE: The purpose of this study was to test heat-treatment methods for improving the cytocompatibility of dental 3D printable photopolymer resins. METHODS: Nextdent C&B resin and a digital light processing 3D printer were used to print all specimens, which were divided into seven groups as follows: 1-month storage at controlled room temperature, 20 to 25 °C (RT), 24-hour storage at RT, 24-hour storage in RT water, 1-min immersion in 80 °C water, 1-min immersion in 100 °C water, 5-min immersion in 100 °C water, and autoclaving. Cell viability tests, cytotoxicity tests, and confocal laser scanning microscopy were performed to analyze the cytocompatibility of the 3D-printed resin. Fourier-transform infrared spectroscopy was performed after heat-treatment to determine the degree of conversion (DC). RESULTS: Immersing printed resin samples in 100 °C water for 1 or 5 min after the curing process was an effective method for increasing cytocompatibility by inducing the preleaching of toxic substances such as unpolymerized monomers, photoinitiators, and additives. Moreover, the DC can be increased by additional polymerization without affecting the mechanical properties of the material. CONCLUSIONS: Immersing the printed photosensitive dental resins in 100 °C water for 5 min is a suitable method for increasing cytocompatibility and the DC.


Assuntos
Temperatura Alta , Água , Teste de Materiais , Propriedades de Superfície , Impressão Tridimensional , Resinas Compostas/química
3.
J Mech Behav Biomed Mater ; 134: 105348, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35843114

RESUMO

This study investigates the effect of acid etching treatment on the surface microstructure, surface roughness, and surface contact angle of zirconia and compares the effects of air abrasion, different etching times, and aging on the shear bond strength (SBS) of resin cement on the zirconia surface. 480 specimens (9 × 10 × 10 mm) were divided into as-sintered and air-abraded groups, and each group was further subdivided into six groups based on etching time (0, 3, 5, 10, 20, and 30 min). The etching solution comprised hydrofluoric acid 25%, sulfuric acid 16%, hydrogen peroxide, methyl alcohol, and purified water. The shear bond strength (SBS), scanning electron microscopy, surface roughness, contact angle, and failure mode were measured. The results indicated that the mean SBS values increased and decreased significantly when the etching times increased to 20 min and 30 min, respectively, in both groups. Further, SBS after aging was lower than that before aging in all groups. Sandblasting, etching time, and aging all showed significant effects (p < 0.001) in the three-way analysis of variance. In addition, the surface roughness increased and the contact angle decreased significantly with an increase in etching time. Thus, the acid-etching treatment induced significant changes on the zirconia surface and increased the SBS of the resin cement. The results of this in vitro study suggest that acid etching is a promising alternative for zirconia surface treatment.


Assuntos
Colagem Dentária , Cimentos de Resina , Cerâmica/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Resistência ao Cisalhamento , Propriedades de Superfície , Ítrio/química , Zircônio/química
4.
J Prosthet Dent ; 127(6): 827-831, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33541819

RESUMO

In studies that assessed the accuracy of implant surgical guides, evaluations were based on the placement position of the implant by using a manufactured surgical guide. However, such assessments could involve errors that may occur during implant placement. Therefore, evaluating the 3-dimensional accuracy of the fabrication of the implant surgical guide itself is not enough. In the evaluation method described in this article, location-related information is obtained by connecting a scan body to the sleeve of the surgical guide instead of directly placing the implant. This helps to evaluate the accuracy of the surgical guide without errors in the placement of an implant.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Imageamento Tridimensional
5.
Polymers (Basel) ; 13(24)2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34960960

RESUMO

Three-dimensional (3D) printing technology is highly regarded in the field of dentistry. Three-dimensional printed resin restorations must undergo a washing process to remove residual resin on the surface after they have been manufactured. However, the effect of the use of different washing solutions and washing times on the biocompatibility of the resulting resin restorations is unclear. Therefore, we prepared 3D-printed denture teeth and crown and bridge resin, and then washed them with two washing solutions (isopropyl alcohol and tripropylene glycol monomethyl ether) using different time points (3, 5, 10, 15, 30, 60, and 90 min). After this, the cell viability, cytotoxicity, and status of human gingival fibroblasts were evaluated using confocal laser scanning. We also analyzed the flexural strength, flexural modulus, and surface SEM imaging. Increasing the washing time increased the cell viability and decreased the cytotoxicity (p < 0.001). Confocal laser scanning showed distinct differences in the morphology and number of fibroblasts. Increasing the washing time did not significantly affect the flexural strength and surface, but the flexural modulus of the 90 min washing group was 1.01 ± 0.21 GPa (mean ± standard deviation), which was lower than that of all the other groups and decreased as the washing time increased. This study confirmed that the washing time affected the biocompatibility and mechanical properties of 3D printed dental resins.

6.
Materials (Basel) ; 14(20)2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34683798

RESUMO

This study analyzed the surface roughness and waviness, Vickers hardness (VHN), and color changes of six types of 3D printed resins and computer-aided design/computer-aided manufacturing (CAD/CAM) materials after artificial toothbrushing. The average surface roughness height (Ra) change of Formlabs denture teeth A2 resin (FMLB) was not significant between after artificial toothbrushing (0.17 ± 0.02 µm and 0.17 ± 0.05 µm, respectively; mean ± standard deviation). However, the Ra value increased significantly in all remaining groups. Regarding waviness, polymethylmethacrylate (PMMA) had the largest increases in average waviness height (Wa) and maximum surface waviness height (Wz) between, before (0.43 ± 0.23 µm and 0.08 ± 0.02 µm), and after (8.67 ± 4.03 µm, 1.30 ± 0.58 µm) toothbrushing. There were no significant changes in Wa for Formlabs denture teeth A2 resin (FMLB) and NextDent C&B (NXT). After artificial toothbrushing, the dispersed-filler composite (DFC) group had the largest color difference (ΔE, of 2.4 ± 0.9), and the remaining materials had smaller changes than the clinical acceptance threshold of ΔE = 2.25. The VHN of FMLB and NXT were 9.1 ± 0.4 and 15.5 ± 0.4, respectively, and were not affected by artificial toothbrushing. The flexural strengths of the 3D printed materials were 139.4 ± 40.5 MPa and 163.9 ± 14.0 MPa for FMLB and NXT, respectively, which were similar to those of the polycarbonate and PMMA groups (155.2 ± 23.6 MPa and 108.0 ± 8.1 MPa, respectively). This study found that the evaluated 3D printed materials had mechanical and optical properties comparable to those of CAD/CAM materials and were stable even after artificial toothbrushing and hydrothermal aging.

7.
Materials (Basel) ; 14(8)2021 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-33921830

RESUMO

The properties of underlying substrates influence the quality of an intraoral scan, but few studies have compared the outcomes using common restorative materials. In this study, we aimed to compare the accuracy of digital and conventional impressions recorded for four different dental materials as the substrates. Experimental crowns were produced with a metallic surface (gold or cobalt-chromium alloy (Co-Cr)) or without a metallic surface (zirconia or PMMA (polymethyl methacrylate)). A conventional impression was made in the conventional group (CON group), and gypsum models were subsequently scanned with a tabletop scanner. An intraoral scanner was used to scan the crowns either after applying a powder spray to reduce the surface reflectivity (IOS-P group) or without the powder spray (IOS group). The scans were assessed in three dimensions for precision and trueness. The accuracy did not differ between the CON and IOS groups for the non-metallic crowns. However, it was statistically different for the Co-Cr metallic crown, reducing trueness observed between groups as CON > IOS > IOS-P. The study evidences the differences in outer surface accuracy observed with a change in the substrate material to be imaged using an oral scanner and with the impression method. These findings suggest that the restoration material present in the oral cavity should be considered when selecting an impression-taking method.

8.
Polymers (Basel) ; 13(8)2021 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-33920389

RESUMO

This study evaluated the internal fit and the accuracy of the implant placement position in order to determine how the surface shape of the tooth and the offset influence the accuracy of the surgical guide. The acquired digital data were analyzed in three dimensions using 3D inspection software. The obtained results confirmed that the internal fit was better in the groove sealing (GS) group (164.45 ± 28.34 µm) than the original shape (OS) group (204.07 ± 44.60 µm) (p < 0.001), and for an offset of 100 µm (157.50 ± 17.26 µm) than for offsets of 30 µm (206.48 ± 39.12 µm) and 60 µm (188.82 ± 48.77 µm) (p < 0.001). The accuracy of implant placement was better in the GS than OS group in terms of the entry (OS, 0.229 ± 0.092 mm; GS, 0.169 ± 0.061 mm; p < 0.001), apex (OS, 0.324 ± 0.149 mm; GS, 0.230 ± 0.124 mm; p < 0.001), and depth (OS, 0.041 ± 0.027 mm; GS, 0.025 ± 0.022 mm; p < 0.001). In addition, the entries (30 µm, 0.215 ± 0.044 mm; 60 µm, 0.172 ± 0.049 mm; 100 µm, 0.119 ± 0.050 mm; p < 0.001) were only affected by the amount of offset. These findings indicate that the accuracy of a surgical guide can be improved by directly sealing the groove of the tooth before manufacturing the surgical guide or setting the offset during the design process.

9.
Materials (Basel) ; 13(23)2020 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-33255922

RESUMO

Recent advances in three-dimensional (3D) printing have introduced new materials that can be utilized for dental restorations. Nonetheless, there are limited studies on the color stability of restorations using 3D-printed crowns and bridge resins. Herein, the color stability of conventional computer-aided design/computer-aided manufacturing (CAD/CAM) blocks and 3D-printing resins was evaluated and assessed for their degrees of discoloration based on material type, colorant types (grape juice, coffee, curry, and distilled water (control group)), and storage duration (2, 7, and 30 days) in the colorants. Water sorption, solubility, and scanning electron microscope (SEM) analyses were conducted. A three-way ANOVA analysis showed that all three factors significantly affected the color change of the materials. Notably, the discoloration (ΔE00) was significantly higher in all 3D printing resins (4.74-22.85 over the 30 days) than in CAD/CAM blocks (0.64-4.12 over the 30 days) following immersion in all colorants. 3D-printing resins showed color differences above the clinical limit (2.25) following storage for 7 days or longer in all experimental groups. Curry was the most prominent colorant, and discoloration increased in almost all groups as the storage duration increased. This study suggests that discoloration must be considered when using 3D printing resins for restorations.

10.
Polymers (Basel) ; 12(11)2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33238528

RESUMO

Three-dimensional (3D) printing is increasingly being utilized in the dental field. After fabricating a prosthesis using a 3D printed resin, a post-curing process is required to improve its mechanical properties, but there has been insufficient research on the optimal post-curing conditions. We used various 3D printed crown and bridge materials in this study, and evaluated the changes in their properties according to post-curing time by evaluating the flexural strength, Weibull modulus, Vickers hardness, color change, degree of conversion, and biocompatibility. The obtained results confirmed that the strength of the 3D printed resin increased when it was post-cured for 60-90 min. The Vickers hardness, the degree of conversion, and biocompatibility of the 3D printed resins increased significantly around the beginning of the post-curing time, and then increased more gradually as the post-curing time increased further. It was observed that the color tone also changed as the post-curing time increased, with some groups showing a ΔE00 value of ≥ 2.25, which can be recognized clinically. This study has confirmed that, after the printing process of a 3D printed resin was completed, a sufficient post-curing time of at least 60 min is required to improve the overall clinical performance of the produced material.

11.
J Clin Med ; 9(4)2020 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-32295304

RESUMO

In the absence of accurate medical records, it is critical to correctly classify implant fixture systems using periapical radiographs to provide accurate diagnoses and treatments to patients or to respond to complications. The purpose of this study was to evaluate whether deep neural networks can identify four different types of implants on intraoral radiographs. In this study, images of 801 patients who underwent periapical radiographs between 2005 and 2019 at Yonsei University Dental Hospital were used. Images containing the following four types of implants were selected: Brånemark Mk TiUnite, Dentium Implantium, Straumann Bone Level, and Straumann Tissue Level. SqueezeNet, GoogLeNet, ResNet-18, MobileNet-v2, and ResNet-50 were tested to determine the optimal pre-trained network architecture. The accuracy, precision, recall, and F1 score were calculated for each network using a confusion matrix. All five models showed a test accuracy exceeding 90%. SqueezeNet and MobileNet-v2, which are small networks with less than four million parameters, showed an accuracy of approximately 96% and 97%, respectively. The results of this study confirmed that convolutional neural networks can classify the four implant fixtures with high accuracy even with a relatively small network and a small number of images. This may solve the inconveniences associated with unnecessary treatments and medical expenses caused by lack of knowledge about the exact type of implant.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...