Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiat Prot Dosimetry ; 199(17): 2118-2125, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37581005

RESUMO

A particle dosemeter (PD) is a payload of NEXTSat-2 in the low-earth orbit (LEO). The absorbed dose in LEO needs to be converted into the ambient dose equivalent (H*(10)). Due to a mixed field in LEO, the calibration factors (klow and khigh) should be determined for the low-and high-linear energy transfers (LET) (below and above 1.5 keV/µm), respectively. The PD was irradiated with a 137Cs source at the Korea Radiation Solution facility to obtain H*(10) and absorbed doses. However due to the lack of sources for the high-LET calibration, H*(10) and an absorbed dose were calculated by simulating PD for the high-energy neutron field at CERN-EU high-energy Reference Field. The measured klow of PD had a difference of 5.1% and 9.5% from the calculated value of PD and the measured value of Liulin detectors, respectively. However, a difference in khigh between PD and Liulin was explained by the contribution of non-neutron components to Liulin in the measurements.

2.
Sensors (Basel) ; 21(23)2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34884033

RESUMO

A lunar vehicle radiation dosimeter (LVRAD) has been proposed for studying the radiation environment on the lunar surface and evaluating its impact on human health. The LVRAD payload comprises four systems: a particle dosimeter and spectrometer (PDS), a tissue-equivalent dosimeter, a fast neutron spectrometer, and an epithermal neutron spectrometer. A silicon photodiode sensor with compact readout electronics was proposed for the PDS. The PDS system aims to measure protons with 10-100 MeV of energy and assess dose in the lunar space environment. The manufactured silicon photodiode sensor has an effective area of 20 mm × 20 mm and thickness of 650 µm; the electronics consist of an amplifier, analog pulse processor, and a 12-bit analog-to-digital converter for signal readout. We studied the responses of silicon sensors which were manufactured with self-made electronics to gamma rays with a wide range of energies and proton beams.


Assuntos
Dosímetros de Radiação , Silício , Raios gama , Humanos , Nêutrons , Prótons , Radiometria
3.
Phys Med Biol ; 64(17): 17NT02, 2019 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-31269471

RESUMO

The tissue equivalent proportional counter (TEPC) is widely recognized as an important dosimetric technique particularly for complex radiation fields. The Korea Astronomy and Space Science Institute (KASI) has recently developed a new spherical TEPC to monitor the space radiation environment in the low earth orbit. The purpose of this study is to examine the performance of the TEPC against standard photon (137Cs) and neutron (252Cf) sources through ground-based measurements and Monte Carlo simulations prior to its actual implementation. Lineal energy distributions, microdosimetric spectra and dosimetric quantities for a 2 µm simulated site in pure propane gas were determined for both sources. Both the measured and calculated 137Cs spectra were shown to occur below 11 keV µm-1 that is the typical range covered by photon sources. Complete coincidence of their electron edge regions was also observed. Meanwhile, the proton edge from the measured 252Cf spectra was found to be in good agreement with those from the simulated ones and the literature. The gamma, recoil proton and heavy ions peaks expected for neutron sources were well defined, albeit deviations in the gamma region. The absorbed dose and dose equivalent for both irradiation conditions were also successfully obtained. The dose equivalent for 252Cf was found to be ten times the absorbed dose whereas it remained the same for 137Cs. The discrepancies observed in the low lineal energy region for both irradiation conditions were caused by intrinsic limitations on the experimental set-up and simulation configurations. This mainly contributed to a difference in the measured and calculated dose mean lineal energies of about 4.1% and 8.7% for the photon and neutron cases, respectively. Nevertheless, fair consistency with published data suggested that our TEPC could adequately reproduce the expected microdosimetric distributions for complex radiation fields.


Assuntos
Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioisótopos de Césio , Elétrons , Raios gama , Humanos , Método de Monte Carlo , Nêutrons , Fótons , Prótons , Dosagem Radioterapêutica
4.
JBJS Case Connect ; 5(3): e83, 2015 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-29252593

RESUMO

CASE: Emphysematous cystitis is a rare, complicated urinary tract infection that is potentially life-threatening if left untreated. We present the case of an eighty-one-year-old woman with left hip pain from a low-energy fall with no associated urinary symptoms. Pelvic computed tomography revealed a left femoral neck fracture and an air-fluid level in the bladder. Bipolar hemiarthroplasty was delayed for three weeks to allow for the potentially serious urinary tract infection to resolve. CONCLUSION: Increased awareness is required for early diagnosis and treatment of asymptomatic emphysematous cystitis in a patient presenting with musculoskeletal symptoms.

5.
JBJS Case Connect ; 5(2): e401-e407, 2015 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-29252609

RESUMO

CASE: A forty-three-year-old male patient complained of difficulty walking due to severe hip and knee pain and stiffness, which had persisted for twenty years. He was found to have multifocal melorheostosis involving the axial skeleton and the entire left lower limb, along with complex vascular and lymphatic malformations corresponding to the sclerotomes related to the skeletal anomalies. Total hip and knee arthroplasties were performed. He was eventually free of pain during walking, and joint motion of the hip and knee was substantially improved after surgery. CONCLUSION: Hip and knee pain and contracture resulting from multifocal melorheostosis were successfully treated with total hip and knee arthroplasty.

6.
JBJS Case Connect ; 5(2): e40, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-29252695

RESUMO

CASE: A forty-three-year-old male patient complained of difficulty walking due to severe hip and knee pain and stiffness, which had persisted for twenty years. He was found to have multifocal melorheostosis involving the axial skeleton and the entire left lower limb, along with complex vascular and lymphatic malformations corresponding to the sclerotomes related to the skeletal anomalies. Total hip and knee arthroplasties were performed. He was eventually free of pain during walking, and joint motion of the hip and knee was substantially improved after surgery. CONCLUSION: Hip and knee pain and contracture resulting from multifocal melorheostosis were successfully treated with total hip and knee arthroplasty.

7.
Science ; 346(6210): 732-5, 2014 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-25378620

RESUMO

Extragalactic background light (EBL) anisotropy traces variations in the total production of photons over cosmic history and may contain faint, extended components missed in galaxy point-source surveys. Infrared EBL fluctuations have been attributed to primordial galaxies and black holes at the epoch of reionization (EOR) or, alternately, intrahalo light (IHL) from stars tidally stripped from their parent galaxies at low redshift. We report new EBL anisotropy measurements from a specialized sounding rocket experiment at 1.1 and 1.6 micrometers. The observed fluctuations exceed the amplitude from known galaxy populations, are inconsistent with EOR galaxies and black holes, and are largely explained by IHL emission. The measured fluctuations are associated with an EBL intensity that is comparable to the background from known galaxies measured through number counts and therefore a substantial contribution to the energy contained in photons in the cosmos.

8.
J Korean Surg Soc ; 83(4): 227-36, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23091795

RESUMO

PURPOSE: Hepatobiliary surgery has changed dramatically in recent decades with the advent of laparoscopic techniques. The aim of this retrospective study was to compare survival rates according to stages, adjusting for important prognostic factors. METHODS: A retrospective study of a 17-year period from January 1994 to April 2011 was carried out. The cases studied were divided into two time period cohorts, those treated in the first 9-years (n = 109) and those treated in the last 7-years (n = 109). RESULTS: An operation with curative intent was performed on 218 patients. The 5-year survival rates according to the depth of invasion were 86% (T1), 56% (T2), 45% (T3), and 5% (T4). The number of cases of incidental gallbladder cancer found during 3,919 laparoscopic cholecystectomies was 96 (2.4%). Incidental gallbladder cancer revealed a better survival rate (P = 0.003). Iatrogenic bile spillage was found in 20 perforations of the gallbladder during laparoscopic cholecystectomies, 16 preoperative percutaneous transhepatic gallbladder drainages and 16 percutaneous transhepatic biliary drainages; only percutaneous transhepatic biliary drainage patients showed a significantly lower survival rate than patients without iatrogenic bile spillage (P < 0.034). Chemoradiation appeared to improve overall survival (P < 0.001). Multivariate analysis also revealed that time period, type of surgery, surgical margin, lymphovascular invasion, lymph node involvement, and chemoradiation therapy had significant effects. CONCLUSION: This study found that the prognosis of gallbladder cancer is still determined by the stage at presentation due to the aggressive biology of this tumor. Early diagnosis, radical resection and appropriate adjuvant therapy can increase overall survival.

9.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-117813

RESUMO

PURPOSE: Hepatobiliary surgery has changed dramatically in recent decades with the advent of laparoscopic techniques. The aim of this retrospective study was to compare survival rates according to stages, adjusting for important prognostic factors. METHODS: A retrospective study of a 17-year period from January 1994 to April 2011 was carried out. The cases studied were divided into two time period cohorts, those treated in the first 9-years (n = 109) and those treated in the last 7-years (n = 109). RESULTS: An operation with curative intent was performed on 218 patients. The 5-year survival rates according to the depth of invasion were 86% (T1), 56% (T2), 45% (T3), and 5% (T4). The number of cases of incidental gallbladder cancer found during 3,919 laparoscopic cholecystectomies was 96 (2.4%). Incidental gallbladder cancer revealed a better survival rate (P = 0.003). Iatrogenic bile spillage was found in 20 perforations of the gallbladder during laparoscopic cholecystectomies, 16 preoperative percutaneous transhepatic gallbladder drainages and 16 percutaneous transhepatic biliary drainages; only percutaneous transhepatic biliary drainage patients showed a significantly lower survival rate than patients without iatrogenic bile spillage (P < 0.034). Chemoradiation appeared to improve overall survival (P < 0.001). Multivariate analysis also revealed that time period, type of surgery, surgical margin, lymphovascular invasion, lymph node involvement, and chemoradiation therapy had significant effects. CONCLUSION: This study found that the prognosis of gallbladder cancer is still determined by the stage at presentation due to the aggressive biology of this tumor. Early diagnosis, radical resection and appropriate adjuvant therapy can increase overall survival.


Assuntos
Humanos , Bile , Biologia , Colecistectomia Laparoscópica , Estudos de Coortes , Drenagem , Diagnóstico Precoce , Vesícula Biliar , Neoplasias da Vesícula Biliar , Laparoscopia , Linfonodos , Análise Multivariada , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...