Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Contraception ; : 110490, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38762199

RESUMO

OBJECTIVE: To summarize and update information regarding drug-drug interactions (DDIs) between antiretrovirals (ARVs) and hormonal contraceptives (HCs). DESIGN: Systematic review METHODS: We searched seven databases for peer-reviewed publications from January 1, 2015, through December 31, 2023, including studies of women using ARVs and HCs concurrently with outcomes including therapeutic effectiveness or toxicity, pharmacokinetics (PK), or pharmacodynamics. We summarized findings and used checklists to assess evidence quality. RESULTS: We included 49 articles, with clinical, ARV or HC PK outcomes reported by 39, 25, and 30 articles, respectively, with some articles reporting outcomes in two or more categories. Fifteen of 18 articles assessing DDIs between efavirenz and progestin implants, emergency contraception, or combined hormonal intravaginal rings found higher pregnancy rates, luteal progesterone levels suggesting ovulation, or reduced progestin PK values. Five studies documented that CYP2B6 single nucleotide polymorphisms exacerbated this DDI. One cohort detected doubled bone density loss with concomitant depot medroxyprogesterone acetate (DMPA) and tenofovir disoproxil fumarate (TDF)-containing ART use versus TDF alone. No other studies described DDIs impacting clinical outcomes. Few adverse events were attributed to ARV-HC use with none exceeding Grade 2. Evidence quality was generally moderate, with dis-similar treatment and control groups, identifying and controlling for confounding, and minimizing attrition bias in the study design being the most frequent limitations. CONCLUSION: Most ARVs and HCs may be used safely and effectively together. TDF-DMPA DDIs warrant longer-term study on bone health and consideration of alternate combinations. For efavirenz-based ART, client counselling on relative risks, including both potential increase in pregnancy rate with concomitant efavirenz and implant use and lower pregnancy rates compared to other HCs even with concomitant efavirenz use, should continue to allow users comprehensive method choice.

2.
Contraception ; 134: 110415, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38431257

RESUMO

OBJECTIVE: To evaluate menstrual cup use and intrauterine device (IUD) expulsion. STUDY DESIGN: We performed a secondary analysis of a 3-year contraceptive efficacy trial comparing two copper 380 mm2 IUDs. Investigators randomized participants approximately 1:4 to the TCu380A or NTCu380-Mini IUD. Approximately 12 months after enrollment began, we advised participants against menstrual cup use due to observed IUD expulsions in cup users. We evaluated IUD expulsion (including spontaneous partial and complete expulsion and accidental self-removal) at 12 and 36 months. We used multivariable logistic regression to evaluate IUD expulsion by age, baseline menstrual volume, body mass index, IUD type, menstrual cup use, parity, and uterine length. RESULTS: This analysis included 1046 participants (203 TCu380A and 843 NTCu380-Mini), with 879 (84.0%) nulliparas. Through 12 and 36 months, expulsion occurred in 74 (7.1%, 95% CI 5.5-8.6%) and 133 (12.7%, 95% CI 10.7-14.7%) participants, respectively. Overall, 250 (23.9%) reported menstrual cup use. More menstrual cup users than non-users experienced expulsion through 12 months (32/203 [15.8%] vs. 42/843 [5.0%]) and 36 months (58/250 [23.2%] vs. 75/796 [9.4%]). Through 36 months, NTCu380-Mini menstrual cup users had higher expulsion odds, while TCu380A cup users did not. Menstrual cup users more frequently experienced accidental self-removal than non-users in participants using the TCu380A (3/53 [5.7%] vs. 0/150 [0.0%]) and the NTCu380-Mini (20/197 [10.2%] vs. 7/646 [1.1%]). In multivariable regression, we found increased odds of expulsion through 36 months in participants using menstrual cups with the NTCu380-Mini (aOR 3.13, 95% CI 1.16-8.46) and <25 years (aOR 1.59, 95% CI 1.07-2.34). CONCLUSIONS: We found higher odds of IUD expulsion with menstrual cup and concurrent NTCu380-Mini IUD use over 36 months of use, but not with concurrent TCu380A IUD use. Menstrual cup users experienced higher likelihood of accidental self-removal regardless of IUD type. IMPLICATIONS: Menstrual cup and NTCu380-Mini use may increase IUD expulsion risk and may increase accidental self-removal risk with TCu380A and NTCu380-Mini use. Clinicians should advise patients of these risks and consider warning patients using an IUD shaped like the NTCu380-Mini (Nova-T frames) of expulsion risk with menstrual cup use.


Assuntos
Expulsão de Dispositivo Intrauterino , Dispositivos Intrauterinos de Cobre , Produtos de Higiene Menstrual , Humanos , Feminino , Dispositivos Intrauterinos de Cobre/efeitos adversos , Adulto , Adulto Jovem , Modelos Logísticos
3.
PLoS One ; 18(11): e0294285, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37948399

RESUMO

BACKGROUND: South Africa is among the countries with the highest prevalence of sexually transmitted infections (STIs), including Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG). In 2017, there were an estimated 6 million new CT, 4.5 million NG and 71 000 Treponema pallidum infections among South African men and women of reproductive age. METHODS: We evaluated STI prevalence and incidence and associated risk factors in 162 women aged 18-33 years old, residing in eThekwini and Tshwane, South Africa who were part of the Evidence for Contraceptive Options and HIV Outcomes (ECHO) trial. Women were randomised to use depot medroxyprogesterone acetate (n = 53), copper intrauterine device (n = 51), or levonorgestrel (n = 58) implant. Lateral vaginal wall swab samples were collected prior to contraceptive initiation and at months one and three following contraceptive initiation for STI testing. RESULTS: There were no significant differences in STI incidence and prevalence across contraceptive groups. At baseline, 40% had active STIs (CT, NG, Trichomonas vaginalis (TV), Mycoplasma genitalium (MG) or herpes simplex virus-2 shedding across all age groups- 18-21 years (46%), 22-25 years (42%) and 26-33 years (29%). The incidence of STIs during follow-up was exceptionally high (107.9/100 women-years [wy]), with younger women (18-21 years) more likely to acquire CT (75.9/100 wy) compared to 26-33 year olds (17.4/100 wy; p = 0.049). TV incidence was higher in the 26-33 year old group (82.7/100 wy) compared to the 18-21 year olds (8.4/100 wy; p = 0.01). CONCLUSIONS: Although the study participants received extensive counselling on the importance of condom use, this study highlights the high prevalence and incidence of STIs in South African women, especially amongst young women, emphasising the need for better STI screening and management strategies.


Assuntos
Infecções por Chlamydia , Infecções por HIV , Infecções Sexualmente Transmissíveis , Trichomonas vaginalis , Masculino , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , África do Sul/epidemiologia , Anticoncepcionais , Prevalência , Incidência , Infecções Sexualmente Transmissíveis/prevenção & controle , Chlamydia trachomatis , Neisseria gonorrhoeae , Infecções por HIV/epidemiologia , Infecções por HIV/prevenção & controle , Infecções por Chlamydia/epidemiologia , Infecções por Chlamydia/diagnóstico
4.
Contracept X ; 5: 100092, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37188149

RESUMO

Objectives: To assess the rates of failed insertion, expulsion, and perforation when intrauterine device (IUD) insertions were done by newly trained clinicians, and to examine factors that may affect these outcomes. Study design: We evaluated skill-based outcomes following IUD insertion at 12 African sites in a secondary analysis of the Evidence for Contraceptive Options and HIV Outcomes (ECHO) randomized trial. Before trial initiation, we provided competency-based IUD training to clinicians and offered ongoing clinical support. We used Cox proportional hazards regression to examine factors associated with expulsion. Results: Among 2582 IUD acceptors who underwent first attempted IUD insertion, 141 experienced insertion failure (5.46%) and seven had uterine perforation (0.27%). Perforation was more common among breastfeeding women within three months postpartum (0.65%) compared with non-breastfeeding women (0.22%). We recorded 493 expulsions (15.5 per 100 person-years, 95% confidence interval [CI] 14.1─16.9): 383 partial and 110 complete. The risk of IUD expulsion was lower among women older than 24 years (aHR 0.63, 95% CI 0.50─0.78) and may be higher among nulliparous women. (aHR 1.65, 95% CI 0.97─2.82). Breastfeeding (aHR 0.94, 95% CI 0.72─1.22) had no significant effect on expulsion. IUD expulsion rate was highest during the first three months of the trial. Conclusions: IUD insertion failure and uterine perforation rates in our study were comparable to those reported in the literature. These results suggest that training, ongoing support, and opportunities to apply new skills were effective in ensuring good clinical outcomes for women receiving IUD insertion by newly trained providers. Implications: Data from this study support recommendations to program managers, policymakers, and clinicians that IUDs can be inserted safely in resource-constrained settings when providers receive appropriate training and support.

5.
PDA J Pharm Sci Technol ; 77(2): 115-132, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36241212

RESUMO

Some members of MIT's Consortium on Adventitious Agent Contamination in Biomanufacturing (CAACB) previously published content on the "Quality Risk Management in the Context of Viral Contamination", which described tools, procedures, and methodologies for assessing and managing the risk of a potential virus contamination in cell culture processes. To address the growing industry interest in moving manufacturing toward open ballrooms with functionally closed systems and to demonstrate how the ideas of risk management can be leveraged to perform a risk assessment, CAACB conducted a case study exercise of these new manufacturing modalities. In the case study exercise, a cross-functional team composed of personnel from many of CAACB's industry membership collaboratively assessed the risks of viral cross-contamination between a human and non-human host cell system in an open manufacturing facility. This open manufacturing facility had no walls to provide architectural separation of two processes occurring simultaneously, specifically a recombinant protein perfusion cell culture process using the human cell line, HEK-293 (Process 1) and a downstream postviral filtration unit operation (Process 2) of a recombinant protein produced in CHO cells. This viral risk assessment focused on cross-contamination of the Process 2 filtration unit operation after the Process 1 perfusion bioreactor was contaminated with a virus that went undetected. The workflow for quality risk management that is recommended by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) was followed, which included identifying and mapping the manufacturing process, defining the risk question, risk evaluation, and risk control. The case study includes a completed Failure Mode and Effects Analysis (FMEA) to provide descriptions of the specific risks and corresponding recommended risk reduction actions.


Assuntos
Gestão de Riscos , Vírus , Cricetinae , Animais , Humanos , Cricetulus , Células HEK293 , Medição de Risco , Proteínas Recombinantes
6.
EClinicalMedicine ; 51: 101554, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35865736

RESUMO

Background: The most widely used copper intrauterine device (IUD) in the world (the TCu380A), and the only product available in many countries, causes side effects and early removals for many users. These problems are exacerbated in nulliparous women, who have smaller uterine cavities compared to parous women. We compared first-year continuation rates and reasons/probabilities for early removal of the TCu380A versus a smaller Belgian copper IUD among nulliparous users. Methods: This 12-month interim report is derived from a pre-planned interim analysis of a sub population and focused on key secondary comparative endpoints. In this participant-blinded trial at 16 centres in the USA, we randomised participants aged 17-40 in a 4:1 ratio to the NT380-Mini or the TCu380A. In the first year, participants had follow-up visits at 6-weeks and 3, 6, and 12-months, and a phone contact at 9 months; we documented continued use, expulsions, and reasons for removal. Among participants with successful IUD placement, we compared probabilities of IUD continuation and specific reasons for discontinuation using log-rank tests. This trial is registered with ClinicalTrials.gov number NCT03124160 and is closed to recruitment. Findings: Between June 1, 2017, and February 25, 2019, we assigned 927 nulliparous women to either the NT380-Mini (n = 744) or the TCu380A (n = 183); the analysis population was 732 (NT380-Mini) and 176 (TCu380A). Participants using the NT380-Mini, compared to the TCu380A, had higher 12-month continuation rates (78·7% [95% CI: 72·9-84·5%] vs. 70·2% [95% CI: 59·7-80·7], p = 0·014), lower rates of removal for bleeding and/or pain (8·1% vs. 16·2%, p = 0·003) and lower IUD expulsion rates (4·8% vs. 8·9%, p = 0·023), respectively. Interpretation: The NT380-Mini offers important benefits for a nulliparous population compared to the TCu380A in the first twelve months, when pivotal experiences typically occur. Higher continuation rates with the NT380-Mini may avert disruptions in contraceptive use and help users avoid unintended pregnancy. Funding: Bill & Melinda Gates Foundation, Eunice Kennedy Shriver National Institute of Child Health and Human Development, and Mona Lisa, N.V. (Belgium).

7.
Gates Open Res ; 6: 49, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35614964

RESUMO

Background: Contraceptive-induced menstrual changes (CIMCs) can affect family planning (FP) users' lives in both positive and negative ways, resulting in both opportunities and consequences. Despite this, and despite the important links between FP and menstrual health (MH), neither field adequately addresses CIMCs, including in research, product development, policies, and programs globally. Methods: In November 2020, a convening of both MH and FP experts reviewed the existing evidence on CIMCs and identified significant gaps in key areas. Results: These gaps led to the establishment of a CIMC Task Force in April 2021 and the development of the Global Research and Learning Agenda: Building Evidence on Contraceptive-Induced Menstrual Changes in Research, Product Development, Policies, and Programs Globally (the CIMC RLA) , which includes four research agendas for (1) measurement, (2) contraceptive research and development (R&D) and biomedical research, (3) social-behavioral and user preferences research, and (4) programmatic research. Conclusions: Guided by the CIMC RLA, researchers, product developers, health care providers, program implementers, advocates, policymakers, and funders are urged to conduct research and implement strategies to address the beneficial and negative effects of CIMCs and support the integration of FP and MH. CIMCs need to be addressed to improve the health and well-being of women, girls, and other people who menstruate and use contraceptives globally. Disclaimer : The views expressed in this article are those of the authors. Publication in Gates Open Research does not imply endorsement by the Gates Foundation.

8.
Am J Reprod Immunol ; 88(2): e13542, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35394678

RESUMO

PROBLEM: Data on the effects of contraceptives on female genital tract (FGT) immune mediators are inconsistent, possibly in part due to pre-existing conditions that influence immune mediator changes in response to contraceptive initiation. METHODS: This study included 161 South African women randomised to injectable depot medroxyprogesterone acetate (DMPA-IM), copper intrauterine device (IUD), or levonorgestrel (LNG) implant in the Evidence for Contraceptive Options and HIV Outcomes (ECHO) trial. We measured thirteen cytokines and antimicrobial peptides previously associated with HIV acquisition in vaginal swabs using Luminex and ELISA, before, and at 1 and 3 months after contraceptive initiation. Women were grouped according to an overall baseline inflammatory profile. We evaluated modification of the relationships between contraceptives and immune mediators by baseline inflammation, demographic, and clinical factors. RESULTS: Overall, LNG implant and copper IUD initiation were associated with increases in inflammatory cytokines, while no changes were observed following DMPA-IM initiation. However, when stratifying by baseline inflammatory profile, women with low baseline inflammation in all groups experienced significant increases in inflammatory cytokines, while those with a high baseline inflammatory profile experienced no change or decreases in inflammatory cytokines. CONCLUSION: We conclude that pre-contraceptive initiation immune profile modifies the effect of contraceptives on the FGT innate immune response.


Assuntos
Anticoncepcionais Femininos , Infecções por HIV , Anticoncepcionais Femininos/efeitos adversos , Anticoncepcionais Femininos/farmacologia , Citocinas , Feminino , Genitália , Infecções por HIV/epidemiologia , Humanos , Imunidade Inata , Inflamação , Dispositivos Intrauterinos de Cobre/efeitos adversos , Levanogestrel/efeitos adversos , Levanogestrel/farmacologia , Acetato de Medroxiprogesterona/efeitos adversos , Acetato de Medroxiprogesterona/farmacologia
9.
Contraception ; 108: 37-43, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34848180

RESUMO

OBJECTIVES: The use of intrauterine devices (IUDs) and contraceptive implants in South Africa is low with limited data on patterns of use and reasons for discontinuation. We describe contraceptive preferences and reasons for discontinuation among women enrolled in the Evidence for Contraceptive Options and HIV Outcomes (ECHO) Trial from one trial site. STUDY DESIGN: ECHO, conducted between 2015 and 2018, enrolled and randomized sexually active women, aged 16 to 35, and desiring contraception, to intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (copper-IUD) or a levonorgestrel (LNG) implant; follow-up was 12 to 18 months. We interviewed 829 women at the Durban, South Africa trial site at ECHO Trial exit to ascertain contraceptive preferences at randomization. Reasons for randomized contraceptive discontinuation were collected at ECHO Trial exit and 6 months later. Data were analyzed descriptively. RESULTS: At the final ECHO Trial visit, among women using their randomized contraceptive method (n = 757), 21% discontinued DMPA-IM, 20% discontinued LNG implant and 22% discontinued the copper-IUD. About a quarter from each group discontinued due to problems with bleeding. Among women continuing their randomized contraceptive at trial exit (n = 597), 25% discontinued DMPA-IM within 6 months of exiting the study, 8% discontinued LNG implant and 4% discontinued copper-IUD. A third of women reported wanting to be assigned DMPA-IM at randomization, 20% wanted the LNG implant and 18% the copper-IUD. CONCLUSIONS: Despite some women having preferences about which contraceptive they might be randomized to, discontinuation rates for all three methods at ECHO Trial exit and 6-month post-trial follow-up were low. IMPLICATIONS: Despite limited prior use of IUDs and implants among women enrolled in this study, and a desire by some women to not receive these methods at randomization, discontinuation rates remained low. The provision of quality contraceptive counselling and support may increase uptake and continued use of implants and IUDs.


Assuntos
Anticoncepcionais Femininos , Dispositivos Intrauterinos de Cobre , Dispositivos Intrauterinos Medicados , Adolescente , Adulto , Anticoncepção/métodos , Feminino , Humanos , Levanogestrel , Acetato de Medroxiprogesterona , África do Sul , Adulto Jovem
10.
Chemosphere ; 292: 133380, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34953871

RESUMO

Removal of toxic elements from wastewater effluent has got a lot of attention because of their severe negative effects on human and environmental health. In the past few years, rapid urbanization and industrial activities in developing countries have exacerbated the destruction of the environment. Most of the wastewater effluents are discharged untreated or inadequately treated, which has become a major concern due to its impact on sustainability and the environment. This is imperative to implement, innovative and resourceful wastewater treatment technologies requiring low investment. Among the various treatment technologies, cutting-edge processes in nano-material sciences have recently piqued the interest of scientists. Nanohybrid absorbents have the potential in improving wastewater treatment and increase water supply by utilizing unconventional water resources. Carbon nanotubes, titanium oxide, manganese oxide, activated carbon (AC), magnesium oxide, graphene, ferric oxides, and zinc oxide are examples of nano-adsorbents that are used to eliminate pollutants. This also demonstrated the effective removal of contaminants along with the harmful effects of chemicals, colorants, and metals found in wastewater. The present manuscript examines potential advances in nanotechnology in wastewater treatment for the prevention of water and soil pollution. This systematic review aims to highlight the importance of nanohybrid absorbents treatment technology for wastewater treatment and to explain how nanohybrid absorbents have the potential to revolutionize industrial pollution. There are also other published review articles on this topic but the present review covers an in-depth information on nano-adsorbents and their targeted contaminants.


Assuntos
Nanotubos de Carbono , Poluentes Químicos da Água , Purificação da Água , Humanos , Águas Residuárias/análise , Poluentes Químicos da Água/análise , Poluição da Água
11.
Sex Transm Infect ; 97(4): 249-255, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33208512

RESUMO

OBJECTIVES: Reproductive aged women are at risk of pregnancy and sexually transmitted infections (STI). Understanding drivers of STI acquisition, including any association with widely used contraceptives, could help us to reduce STI prevalence and comorbidities. We compared the risk of STI among women randomised to three contraceptive methods. METHODS: We conducted a secondary analysis to assess the risk of chlamydia and gonorrhoea in a clinical trial evaluating HIV risk among 7829 women aged 16-35 randomised to intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (IUD) or a levonorgestrel (LNG) implant. We estimated chlamydia and gonorrhoea prevalences by contraceptive group and prevalence ratios (PR) using log-binomial regression. RESULTS: At baseline, chlamydia and gonorrhoea prevalences were 18% and 5%, respectively. Final visit chlamydia prevalence did not differ significantly between DMPA-IM and copper IUD groups or between copper IUD and LNG implant groups. The DMPA-IM group had significantly lower risk of chlamydia compared with the LNG implant group (PR 0.83, 95% CI 0.72 to 0.95). Final visit gonorrhoea prevalence differed significantly only between the DMPA-IM and the copper IUD groups (PR 0.67, 95% CI 0.52 to 0.87). CONCLUSIONS: The findings suggest that chlamydia and gonorrhoea risk may vary with contraceptive method use. Further investigation is warranted to better understand the mechanisms of chlamydia and gonorrhoea susceptibility in the context of contraceptive use.


Assuntos
Infecções por Chlamydia/epidemiologia , Anticoncepção/métodos , Anticoncepcionais Femininos/administração & dosagem , Gonorreia/epidemiologia , Dispositivos Intrauterinos de Cobre , Levanogestrel/administração & dosagem , Acetato de Medroxiprogesterona/administração & dosagem , Adolescente , Adulto , África/epidemiologia , Preparações de Ação Retardada , Suscetibilidade a Doenças , Implantes de Medicamento , Feminino , Humanos , Prevalência , Adulto Jovem
13.
Biol Reprod ; 103(2): 157-166, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32529250

RESUMO

A significant global unmet need for new contraceptive options for both women and men remains due to side effect profiles, medical concerns, and inconvenience of many currently available products. The pharmaceutical industry has largely abandoned early research and development for contraception and will not likely engage to bring new products to the market unless they have been significantly de-risked by showing promise in early phase clinical trials. This lack of interest by big pharma comes at a time when scientific and technological advances in biology and medicine are creating more opportunities than ever for the development of new and innovative drug products. Novel partnerships between the academic sector, small biotechnology companies, foundations, non-government organizations (NGOs), and the federal government could accelerate the development of new contraceptive products. We discuss the challenges and opportunities that we have encountered as an NGO with a mission to develop novel contraceptive products for low- and middle-income countries and how it differs from developing products for higher-income markets. We hope that our experiences and "lessons learned" will be of value to others as they proceed down the product development path, be it for female or male or for hormonal or nonhormonal contraceptives.


Assuntos
Anticoncepção , Anticoncepcionais , Desenvolvimento de Medicamentos , Humanos
14.
Contracept X ; 2: 100026, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32577615

RESUMO

OBJECTIVE: The objective was to address bias in contraception efficacy studies through a randomized study trial of intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (IUDs) and a levonorgestrel (LNG) implant. STUDY DESIGN: We analyzed data from the Evidence for Contraceptive Options and HIV Outcomes Trial, which assessed HIV incidence among 7829 women from 12 sites in eSwatini, Kenya, South Africa and Zambia seeking effective contraception and who consented to be randomized to DMPA-IM, copper IUD or LNG implant. We used Cox proportional hazards regression adjusted for condom use to compare pregnancy incidence during both perfect and typical (i.e., allowing temporary interruptions) use. RESULTS: A total of 7710 women contributed to this analysis. Seventy pregnancies occurred during perfect and 85 during typical use. There was no statistically significant difference in perfect use pregnancy incidence among the methods: 0.61 per 100 woman-years for DMPA-IM [95% confidence interval (CI) 0.36-0.96], 1.06 for copper IUD (95% CI 0.72-1.50) and 0.63 for LNG implants (95% CI 0.39-0.96). Typical use pregnancy rates were also largely similar: 0.87 per 100 woman-years for DMPA-IM (95% CI 0.58-1.25), 1.11 for copper IUD (95% CI 0.77-1.54) and 0.63 for LNG implants (95% CI 0.39-0.96). CONCLUSIONS: In this randomized trial of highly effective contraceptive methods among African women, both perfect and typical use resulted in low pregnancy rates. Our findings provide strong justification for improving access to a broader range of longer-acting contraceptive options including LNG implants and copper IUD for African women. IMPLICATIONS STATEMENT: Data from this study support recommendations to providers, policy makers and patients that all of these methods provide safe and highly effective contraception for African women.

15.
AIDS Res Hum Retroviruses ; 36(8): 632-640, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32394723

RESUMO

Limited data exist on the effects of contraceptives on HIV disease progression. We studied the association between intramuscular injectable depot medroxyprogesterone acetate (DMPA-IM), the copper intrauterine device (IUD), and the levonorgestrel (LNG) implant on markers of HIV disease progression at the time of HIV detection and 3 months postdetection and time from detection to CD4 count <350 cells/mm3. Among women initiating antiretroviral therapy (ART), we studied the effect of contraceptive group on time from ART initiation to viral load (VL) <40 copies/mL. We included women 16-35 years randomized to DMPA-IM, copper IUD, or LNG implant with incident HIV infection during the Evidence for Contraceptive Options and HIV Outcomes (ECHO) trial (n = 382). We analyzed HIV VL and CD4 cell count according to participants' randomized method and also conducted a "continuous use" analysis that excluded follow-up time after method discontinuation. We used adjusted linear models to compare mean VL and CD4 cell levels by contraceptive group up to the time of ART initiation. We compared time from HIV detection to CD4 count <350 cells/mm3 and, following ART initiation, time to viral suppression (VL <40 copies/mL) using Cox proportional hazards models. At HIV detection, women allocated to DMPA-IM had lower VL relative to copper IUD (-0.28 log10 copies/mL; 95% confidence interval [CI]: -0.55 to -0.01) and LNG implant (-0.27, CI: -0.55 to 0.02) and higher mean CD4 than copper IUD users by 66 cells/mm3 (CI: 11-121). In continuous use analyses women allocated to DMPA-IM progressed to CD4 < 350 cells/mm3 slower than copper IUD users (hazard ratio [HR] = 0.6, CI: 0.3-1.1), whereas copper IUD users progressed faster than LNG implant users (HR = 1.8, CI: 1.0-3.3). Time to viral suppression was faster for DMPA-IM than copper IUD (HR = 1.5, CI: 1.0-2.3) and LNG implant 1.4 (CI: 0.9-2.2) users. We found no evidence of more rapid early HIV disease progression among women using DMPA-IM than among women using copper IUD or LNG implant. Our finding of more rapid progression among copper IUD compared with DMPA-IM users should be interpreted cautiously.


Assuntos
Infecções por HIV/imunologia , Dispositivos Intrauterinos de Cobre/estatística & dados numéricos , Levanogestrel/farmacologia , Acetato de Medroxiprogesterona/administração & dosagem , Carga Viral/efeitos dos fármacos , Adolescente , Adulto , Contagem de Linfócito CD4 , Progressão da Doença , Feminino , Infecções por HIV/complicações , Infecções por HIV/fisiopatologia , Contracepção Hormonal , Humanos , Dispositivos Intrauterinos de Cobre/normas , Modelos de Riscos Proporcionais , Adulto Jovem
17.
AIDS ; 33(13): 1995-2004, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31306173

RESUMO

OBJECTIVES: To evaluate pharmacokinetics and pharmacogenetics of contraceptive implant progestin concentrations in HIV-positive women initiating efavirenz (EFV)-containing or nevirapine (NVP)-containing antiretroviral therapy (ART). DESIGN: We analyzed stored samples from women self-reporting implant use in the Partners PrEP Study. METHODS: Plasma samples collected every 6 months were analyzed for levonorgestrel and etonogestrel concentrations. Progestin concentrations from samples collected after ART initiation were compared with pre-ART concentrations for intraindividual comparisons. We used adjusted linear mixed models to compare hormone concentrations between individuals on EFV and NVP to a no ART group. We then evaluated whether possessing certain alleles with known or possible influences on EFV, NVP, or progestin metabolism were associated with changes in progestin concentrations or modified the association between ART use and progestin concentrations. RESULTS: Our analysis included 11 women who initiated EFV, 13 who initiated NVP, and 36 who remained ART-naive. In the EFV group, the adjusted geometric mean ratio (aGMR) of levonorgestrel was 0.39 [90% confidence intervals (0.31, 0.49); P < 0.001] and the etonogestrel aGMR was 0.51 (0.34, 0.76; P = 0.006) compared with the control group. No difference was observed in the NVP group compared with controls [levonorgestrel 0.93 (0.74, 1.18); P = 0.64; etonogestrel 1.07 (0.77, 1.50); P = 0.73]. Possession of four allele variants were found to result in further reductions in progestin concentrations among those receiving EFV. CONCLUSION: Concomitant use of EFV significantly reduces levonorgestrel or etonogestrel concentrations by 61 and 49%, respectively, compared with no ART use. We also report allelic variants in hepatic enzymes that influenced the extent of the observed drug-interaction between progestins and EFV.


Assuntos
Fármacos Anti-HIV/administração & dosagem , Benzoxazinas/administração & dosagem , Anticoncepcionais Femininos/farmacocinética , Desogestrel/farmacocinética , Antagonismo de Drogas , Levanogestrel/farmacocinética , Adulto , Alcinos , Anticoncepcionais Femininos/administração & dosagem , Ciclopropanos , Desogestrel/administração & dosagem , Feminino , Infecções por HIV/tratamento farmacológico , Humanos , Quênia , Levanogestrel/administração & dosagem , Modelos Lineares , Nevirapina/administração & dosagem , Testes Farmacogenômicos , Uganda
18.
Glob Health Sci Pract ; 7(2): 317-328, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31189699

RESUMO

BACKGROUND: Observational studies raise concern about a potential link between injectable progestin contraceptive use and HIV acquisition risk. This possible link is particularly relevant in sub-Saharan Africa where HIV risk is high and the method mix is skewed toward injectables. We developed the Planning for Outcomes (P4O) model (https://planning4outcomes.ctiexchange.org/) to predict changes in maternal and child health (MCH) and HIV outcomes that could occur if the proportion of injectables in the method mix is changed. METHODS: P4O incorporates evidence-based assumptions to predict yearly changes in unintended pregnancies, morbidity/mortality, HIV infections (women and infants), and anticipated health care costs associated with changing the proportions of injectable users in 22 selected countries. Users of this model designate all countries or a subset and adjust inputs including percentage of injectable users who discontinue, percentage of discontinuers who begin use of an alternative method, hazard ratio for HIV infection with injectable use, method mix used by injectable discontinuers, annual probabilities of method-specific pregnancy and mother-to-child transmission of HIV, condom effectiveness against HIV, risk of HIV during pregnancy, and HIV incidence among women of reproductive age. RESULTS: Illustrative results from all sub-Saharan African countries combined and from selected countries demonstrate the potential of P4O to inform program planning and procurement decisions. In countries with high use of long-acting reversible contraception, the removal of injectables from the method mix is associated with improvement in MCH and HIV indicators if most injectable users switch to more effective methods (e.g., implants). In countries with high use of short-acting methods (e.g., condoms), the model predicts mostly negative MCH outcomes. CONCLUSIONS: Policy makers and program planners may use P4O to inform programming and policy decisions. In all scenarios, programmatic preparation to accommodate changes to the contraceptive method mix, considerations of how the individual desires of women will be addressed, and potential burden of anticipated MCH-related costs warrant advanced consideration.


Assuntos
Anticoncepção/efeitos adversos , Anticoncepcionais Femininos , Infecções por HIV/etiologia , Planejamento em Saúde , Saúde do Lactente , Saúde Materna , Progestinas , Adolescente , Adulto , África Subsaariana , Saúde da Criança , Preservativos , Anticoncepção/métodos , Comportamento Contraceptivo , Anticoncepcionais Femininos/administração & dosagem , Anticoncepcionais Femininos/efeitos adversos , Serviços de Planejamento Familiar/métodos , Feminino , Humanos , Lactente , Transmissão Vertical de Doenças Infecciosas , Masculino , Pessoa de Meia-Idade , Políticas , Gravidez , Complicações Infecciosas na Gravidez/etiologia , Progestinas/administração & dosagem , Progestinas/efeitos adversos , Adulto Jovem
19.
AIDS ; 33(4): 735-744, 2019 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-30585845

RESUMO

BACKGROUND: Some observational studies have found increased HIV risk associated with self-reported use of injectable depot medroxyprogesterone acetate. Testing blood samples for medroxyprogesterone acetate (MPA), the progestin in depot medroxyprogesterone acetate, permits validation of self-reported data, and exploration of whether potential HIV risk is correlated with MPA levels, which are highest soon after injection. METHODS: We conducted a case-control study testing archived serum from women who participated in three longitudinal studies of HIV prevention in East and southern Africa. Case samples, from women who acquired HIV, were from visits that occurred at or immediately prior to the first evidence of HIV infection. Secondary analyses restricted to case samples collected within 15 and 30 days of the estimated date of HIV infection. Matched control samples were from women who remained HIV uninfected. We used multivariable conditional logistic regression to compare exogenous hormone levels, quantified through mass spectrometry, among cases and controls. RESULTS: When restricted to cases with samples collected within 15 days or less of estimated date of HIV infection, MPA detection was more frequent among women who acquired HIV (adjusted odds ratio = 2.75, 95% confidence interval 1.22-6.19). In this subset, the increase in HIV risk was only among samples with MPA detected at a low level of 0.02-0.50 ng/ml: 36.7% of cases and 9.4% of controls, adjusted odds ratio = 6.03, 95% confidence interval 2.50-14.54. CONCLUSION: Detection of MPA at low levels close to the estimated time of HIV acquisition was significantly more frequent among women who acquired HIV. Studies are needed that explore biological mechanisms elicited by any MPA level and HIV risk.


Assuntos
Contraceptivos Hormonais/sangue , Infecções por HIV/epidemiologia , Acetato de Medroxiprogesterona/sangue , Soro/química , Adulto , África Oriental/epidemiologia , África Austral/epidemiologia , Estudos de Casos e Controles , Testes Diagnósticos de Rotina , Feminino , Humanos , Estudos Longitudinais , Masculino , Medição de Risco
20.
Int J Gynaecol Obstet ; 143(3): 277-281, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30191558

RESUMO

Exposure to Zika virus (ZIKV) in pregnancy leads to a spectrum of congenital effects in the newborn. Recent studies have begun to evaluate the impact of ZIKV during pregnancy. Among 39 relevant studies, nine were related specifically to clinical studies of ophthalmologic disorders and one was related to hearing loss impairment; most of these studies were case reports and case series reports. Importantly, congenital toxoplasmosis was ruled out in all studies. The data show that, in addition to microcephaly, ZIKV exposure in pregnancy may result in subtle ocular impairments in the newborn. The most common anomalies are macular pigment mottling and/or chorioretinal atrophy, and optic nerve disorders. Sensorineural hearing loss has also been noted in 5.8% of infants with microcephaly. The effects of ZIKV infection during pregnancy are potentially devastating to the fetus and newborn. Although microcephaly is an important signal, the current information emphasizes the importance of ocular and auditory screenings, otherwise sight and hearing anomalies may be underestimated. Healthcare providers should fully understand the spectrum of anomalies related to ZIKV exposure in pregnancy in order to counsel pregnant women living in high-risk areas, in addition to those wanting to become pregnant.


Assuntos
Oftalmopatias/virologia , Perda Auditiva Neurossensorial/virologia , Complicações Infecciosas na Gravidez/virologia , Efeitos Tardios da Exposição Pré-Natal/virologia , Infecção por Zika virus/complicações , Oftalmopatias/congênito , Feminino , Perda Auditiva Neurossensorial/congênito , Humanos , Recém-Nascido , Microcefalia/virologia , Gravidez , Zika virus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...