Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Abdom Imaging ; 35(4): 481-4, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19557475

RESUMO

The patient was a 63-year-old woman with a chief complaint of blood-stained sputum. A tumor of the inferior vena cava was found on chest computed tomography (CT) and identified as a primary tumor based on multidetector CT and contrast-enhanced MR angiography. An intrapelvic tumor was also discovered. On autopsy, the two tumors were diagnosed as leiomyosarcoma and ovarian fibroma, respectively.


Assuntos
Leiomiossarcoma/diagnóstico , Neoplasias Vasculares/diagnóstico , Veia Cava Inferior , Meios de Contraste , Feminino , Humanos , Leiomiossarcoma/diagnóstico por imagem , Angiografia por Ressonância Magnética , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Neoplasias Vasculares/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/patologia
3.
J Digit Imaging ; 22(6): 598-604, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18196340

RESUMO

To solve the problems of image displays in filmless radiology conferences for the purpose of teaching, we made an experimental design of a conference system with dual 50-in. plasma monitors for displaying larger images and a shared folder containing shortcuts to images for quick display during conferences on the desktop of each client computer in a picture archival and communication system. The image quality of the monitors was evaluated using the TG18-QC test pattern. The display time of images was measured in 20 cases when the shared folder was used and when it was not. Monitor screen size and image quality, operability, display time of images, and overall impression given by the system were evaluated subjectively by five radiologists. Although the image quality of the monitor was not as high as that of the high-resolution monitors used for diagnostic radiology, its performance was good enough for teaching. The average display time using the shared folder (2.6 +/- 0.39 s) was significantly shorter than without it (16.9 +/- 5.04 s; p = 2.85 x 10(-6)). Despite the need for certain improvements in monitor size and in the operability of the system, the radiologists considered the system suitable for radiology teaching conferences. We believe that this system is useful for institutions that intend to introduce a filmless system for filmless radiology teaching conferences.


Assuntos
Terminais de Computador , Instrução por Computador/instrumentação , Intensificação de Imagem Radiográfica/métodos , Radiologia/educação , Congressos como Assunto , Apresentação de Dados , Diagnóstico por Imagem/instrumentação , Humanos , Japão
4.
J Digit Imaging ; 22(6): 689-95, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18941839

RESUMO

Although accurate information on thoracolumbar bone structure is essential when computed tomography (CT) images are examined, there is no automated method of labeling all the vertebrae and ribs on a CT scan. We are developing a computer-aided diagnosis system that labels ribs and thoracolumbar vertebrae automatically and have evaluated its accuracy. A candidate bone was extracted from the CT image volume data by pixel thresholding and connectivity analysis. All non-bony anatomical structures were removed using a linear discriminate of distribution of CT values and anatomical characteristics. The vertebrae were separated from the ribs on the basis of their distances from the centers of the vertebral bodies. Finally, the thoracic cage and lumbar vertebrae were extracted, and each vertebra was labeled with its own anatomical number by histogram analysis along the craniocaudal midline. The ribs were labeled in a similar manner, based on location data. Twenty-three cases were used for accuracy comparison between our method and the radiologist's. The automated labeling of the thoracolumbar vertebrae was concordant with the judgments of the radiologist in all cases, and all but the first and second ribs were labeled correctly. These two ribs were frequently misidentified, presumably because of pericostal anatomical clutter or high densities of contrast material in the injected veins. We are confident that this system can contribute usefully as part of a picture archiving and communication system workstation, though further technical improvement is required for identification of the upper ribs.


Assuntos
Osso e Ossos/diagnóstico por imagem , Imageamento Tridimensional , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Terminologia como Assunto , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Feminino , Humanos , Japão , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Costelas/diagnóstico por imagem , Sensibilidade e Especificidade , Vértebras Torácicas/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...