1.
Sensors (Basel) ; 22(9)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35590968

RESUMO

Optical coherence tomography (OCT) has a wide range of uses in bioimaging and nondestructive testing. Larger bandwidth light sources have recently been implemented to enhance measurement resolution. Increased bandwidth has a negative impact on spectral nonlinearity in k space, notably in the case of spectral domain OCT (SD-OCT). This nonlinearity reduces the depth-dependent signal sensitivity of the spectrometers. A grating and prism combination is extensively used for linearizing. In an earlier study, we used a combination of the reflective grating and prism, as well as a cylindrical mirror with a radius of 180 mm, to achieve a high SR ratio with low nonlinearity. A creative design for a spectrometer with a cylindrical mirror of radius 50 mm, a light source with a center wavelength of 830 ± 100 nm (µm-1 - 6.756 µm-1 in k-space), and a grating of 1600 lines/mm is presented in this work. The design optimization is performed using MATLAB and ZEMAX. In the proposed design, the nonlinearity error reduced from 157∘× µm to 10.75∘× µm within the wavenumber range considered. The sensitivity research revealed that, with the new design, the SR ratio is extremely sensitive to the imaging optics' angles. To resolve this, a spectrometer based on Grism is introduced. We present a Grism-based spectrometer with an optimized SR ratio of 0.97 and nonlinearity of 0.792∘× µm (Δθ/Δk). According to the sensitivity study, the Grism-based spectrometer is more robust.


Assuntos
Óptica e Fotônica , Tomografia de Coerência Óptica , Cintilografia , Tomografia de Coerência Óptica/métodos
2.
Sensors (Basel) ; 21(19)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34640783

RESUMO

We report the design of a high-efficiency spectral-domain spectrometer with cylindrical optics for line scanning optical coherence tomography (OCT). The spectral nonlinearity in k space (wavenumber) lowers the depth-dependent signal sensitivity of the spectrometers. For linearizing, in this design, grating and prism have been introduced. For line scanning, a cylindrical mirror is utilized in the scanning part. Line scanning improves the speed of imaging compared to fly-spot scanning. Line scanning OCT requires a spectrometer that utilizes cylindrical optics. In this work, an optical design of a linear wavenumber spectrometer with cylindrical optics is introduced. While there are many works using grating and prism to linearize the K space spectrometer design, there is no work on linearizing the k-space spectrometer with cylindrical optics for line scanning that provides high sensitivity and high-speed imaging without the need for resampling. The design of the spectrometer was achieved through MATLAB and ZEMAX simulations. The spectrometer design is optimized for the broadband light source with a center wavelength of 830 ± 100 nm (8.607 µm-1- 6.756 µm-1 in k-space). The variation in the output angle with respect to the wavenumber can be mentioned as a nonlinearity error. From our design results, it is observed that the nonlinearity error reduced from 147.0115 to 0.0149 Δθ*µm within the wavenumber range considered. The use of the proposed reflective optics for focusing reduces the chromatic aberration and increases image quality (measured by the Strehl ratio (SR)). The complete system will provide clinicians a powerful tool for real-time diagnosis, treatment, and guidance in surgery with high image quality for in-vivo applications.


Assuntos
Óptica e Fotônica , Tomografia de Coerência Óptica , Cintilografia
3.
Sci Rep ; 10(1): 9730, 2020 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-32546799

RESUMO

We introduced and validated a drop-on-demand method to print cells. The method uses low energy nanosecond laser (wavelength: 532 nm) pulses to generate a transient microbubble at the distal end of a glass microcapillary supplied with bio-ink. Microbubble expansion results in the ejection of a cell-containing micro-jet perpendicular to the irradiation axis, a method we coined Laser Induced Side Transfer (LIST). We show that the size of the deposited bio-ink droplets can be adjusted between 165 and 325 µm by varying the laser energy. We studied the corresponding jet ejection dynamics and determined optimal conditions for satellite droplet-free bioprinting. We demonstrated droplet bio-printing up to a 30 Hz repetition rate, corresponding to the maximum repetition rate of the used laser. Jet ejection dynamics indicate that LIST can potentially reach 2.5 kHz. Finally, we show that LIST-printed human umbilical vein endothelial cells (HUVECs) present negligible loss of viability and maintain their abilities to migrate, proliferate and form intercellular junctions. Sample preparation is uncomplicated in LIST, while with further development bio-ink multiplexing can be attained. LIST could be widely adapted for applications requiring multiscale bioprinting capabilities, such as the development of 3D drug screening models and artificial tissues.


Assuntos
Bioimpressão/instrumentação , Bioimpressão/métodos , Engenharia Tecidual/métodos , Células Endoteliais da Veia Umbilical Humana , Humanos , Tinta , Lasers , Microbolhas , Impressão Tridimensional/instrumentação
4.
J Biomed Opt ; 17(5): 056006, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22612129

RESUMO

The parameters of an off-axis cylindrical mirror-focused line-scanning system were studied to optimize the flatness of the 2 mm scan field. The scanning system parameters included the beam size, the distance between the scanning and the focusing mirror, the angle between the incident beam and the reflected beam, the optical scan angle, and the effective focal length of the cylindrical mirror. Because of the off-axis line-scanning system configuration, the scanning could be carried out either in the tangential (Y-scan) or in the sagittal (X-scan) plane. A 53 nm spectral bandwidth light source was used to evaluate the imaging performance of the scanning system. Since reflective optics is employed in this work for focusing, the scanning system could be used with a higher spectral bandwidth light source for optical coherence tomography applications. The effect of the angle between of the incident and reflected beams, the distance between the mirrors, the focal length of the cylindrical mirror and the scanning directions, on the flatness of the scan field were studied. It was proved that the sagittal scanning is least sensitive to variations in scanning system parameters and thus provides maximum flexibility in design.


Assuntos
Aumento da Imagem/instrumentação , Lasers , Lentes , Tomografia de Coerência Óptica/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade