Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Aust N Z J Obstet Gynaecol ; 62(4): 581-588, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35394065

RESUMO

BACKGROUND: Gynaecology trainees struggle to obtain adequate procedural experience. Training programs integrating virtual reality simulators (VRS) have been suggested as a solution. AIMS: The study aimed to assess if a VRS training program (LapSim® , Surgical Sciences, Göteborg, 2017) improved live operating performance at six months for novice and experienced trainees. Additional outcomes included the association between LapSim® logged time and live operating performance at six months, LapSim® scores and live operating performance at zero and sixmonths and the difference in benefit for novice and experienced gynaecology trainees. METHODS: A prospective intervention study was conducted. Novice and experienced trainees were enrolled, and comparisons made at zero- and six-month time points. The intervention groups were provided with a laparoscopic gynaecology curriculum incorporating VRS. Controls underwent routine training only. Assessment of live operating performance was conducted after six months training. RESULTS: Thirty-five trainees participated, and 25 had access to the VRS curriculum (17 novice and eight experienced trainees). Access to the VRS curriculum and time spent training on the LapSim® made no difference to live operating ability for either intervention group (P > 0.05). The median (interquartile range) hours of VRS usage were 7.9 (4.5-10.8) and 6.0 (4.0-6.8) for novice and experienced trainees respectively. The intervention group provided positive feedback on the utility of VRS in their laparoscopic skill development. CONCLUSION: Optimal utilisation of VRS in Australian training paradigms remains incompletely understood. Further research is required to establish the most effective integration of VRS into training models to ensure uptake and transferability to the operating theatre.


Assuntos
Competência Clínica , Laparoscopia , Austrália , Simulação por Computador , Currículo , Humanos , Laparoscopia/educação , Estudos Prospectivos
2.
Arch Dis Child Fetal Neonatal Ed ; 105(1): 50-55, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31123055

RESUMO

OBJECTIVE: Higher rates of neonatal morbidity and mortality at term combined with earlier spontaneous delivery have led to the hypothesis that babies born to South Asian born (SA-born) women may mature earlier and/or their placental function decreases earlier than babies born to Australian and New Zealand born (Aus/NZ-born) women. Whether babies born to SA-born women do better in the preterm period, however, has yet to be evaluated. In this study we investigated respiratory outcomes, indicative of functional maturity, of preterm babies born to SA-born women compared with those of Aus/NZ-born women to explore this hypothesis further. STUDY DESIGN AND SETTING: This retrospective cohort study was conducted at Monash Health. PATIENTS: Data were collected from neonatal and birth records of moderate-late preterm (32-36 weeks) infants born between 2012 and 2015 to SA-born and Aus/NZ-born women. OUTCOME MEASURES: Rates of nursery admissions and neonatal respiratory outcomes were compared. RESULTS: Babies born to Aus/NZ-born women were more likely to be admitted to a nursery (80%) compared with SA-born babies (72%, p=0.004). Babies born to SA-born mothers experienced significantly less hyaline membrane disease (7.8%), required less resuscitation at birth (28.6%) and were less likely to require ventilation (20%) than babies born to Aus/NZ-born mothers (18%, 42.2%, 34.6%; p<0.001). There was no difference in the duration of ventilation or length of stay in hospital. CONCLUSIONS: Moderate-late preterm babies born to SA-born women appear to have earlier functional maturity, as indicated by respiratory outcomes, than Aus/NZ-born babies. Our findings support the hypothesis of earlier fetal maturation in SA-born women.


Assuntos
Povo Asiático , Doença da Membrana Hialina/epidemiologia , Nascimento Prematuro , Ressuscitação/estatística & dados numéricos , População Branca , Adulto , Sudeste Asiático/etnologia , Austrália , Peso ao Nascer , Índice de Massa Corporal , Estudos de Coortes , Feminino , Glucocorticoides/uso terapêutico , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Mães , Nova Zelândia , Admissão do Paciente/estatística & dados numéricos , Cuidado Pré-Natal , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos
3.
Methods Mol Biol ; 1710: 267-276, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29197009

RESUMO

In vitro functional analyses of cells are widely used to investigate the molecular mechanisms involved in preeclampsia. Common cellular functions studied include adhesion, apoptosis, proliferation, migration, and invasion. At present, most researchers will use endpoint experimental assays that only allow the determination of cell function at a single time point, with the need to repeat the experiment for an alternate time point. Here, we describe an electrical impedance-based tool that allows real-time monitoring of cells, which enables the efficient assessment of multiple time points over the duration of a single experiment.


Assuntos
Técnicas Eletroquímicas/instrumentação , Placenta/citologia , Apoptose , Adesão Celular , Movimento Celular , Proliferação de Células , Impedância Elétrica , Desenho de Equipamento , Feminino , Humanos , Microeletrodos , Gravidez , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...