Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Talanta ; 117: 139-45, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-24209322

RESUMO

An organic thin film photodiode (OPD) was successfully employed as a portable photodetector in a competitive enzyme-linked immunosorbent assay (ELISA) of a class of nonionic surfactants, namely alkylphenol polyethoxylates (APnEOs) which are an environmental pollutant. Microbeads that were chemically immobilized with an anti-APnEOs antibody were used in the assay. The OPD consisted of a layer of copper phthalocyanine (CuPc), C60 and a second layer of bathocuproine (BCP) with a bulk heterojunction composed of CuPc and C60 prepared by a vapor deposition method on an indium-tin oxide coated glass substrate. The OPD showed an incident photon-current efficiency (IPCE) of approximately 19% for light at a wavelength of 585 nm. This relatively high IPCE at 585 nm makes it suitable for detecting the fluorescence of resorufin (λem=585 nm), the product of the competitive ELISA, produced through the enzymatic reaction of Amplex Red with horseradish peroxidase (HRP) and H2O2. A fluorometric detector was assembled on a microchip by combining the fabricated OPD and a commercial LED as a photodetector and a light source, respectively. The photocurrent of the OPD due to the fluorescence of resorufin was proportional to the concentration of resorufin in the concentration range from 0 to 8 µM. When the fabricated OPD was used as a portable photodetector, the competitive ELISA of APnEOs using HRP labeled APnEOs (HRP-APnEOs) was performed on magnetic microbeads on which surface an anti-APnEOs antibody had been immobilized. A typical sigmoidal calibration curve was obtained and the data were in good agreement with a numerical simulation, where the photocurrent of the OPD was plotted against the concentration of APnEOs, determined via the competitive ELISA. The detection limit of the immunoassay for APnEOs was approximately 2 and 4 ppb in batch and flow system, respectively.


Assuntos
Poluentes Ambientais/análise , Ensaio de Imunoadsorção Enzimática/métodos , Imunofluorescência , Técnicas Analíticas Microfluídicas/métodos , Polietilenoglicóis/análise , Tensoativos/análise , Anticorpos/química , Ligação Competitiva , Calibragem , Fulerenos/química , Peroxidase do Rábano Silvestre/química , Peróxido de Hidrogênio/química , Indóis/química , Limite de Detecção , Imãs , Técnicas Analíticas Microfluídicas/instrumentação , Compostos Organometálicos/química , Oxazinas/química , Fenantrolinas/química , Compostos de Estanho/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA