Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-26738123

RESUMO

In this study, the Mooney-Rivlin material with hyperelastic strain energy was proposed for biomechanical modeling of the lung. We modeled the lung as an inhomogeneous Mooney-Rivlin material with uncoupled deviatoric and volumetric behavior. The proposed method was evaluated on the lungs of eight lung cancer patients. For each patient, the lung was segmented from the 4D-CT images and tetrahedral volume mesh of the lung in phase 50% was created by using the adaptive mesh generation toolkit. The demons deformable registration algorithm was used to extract the displacement vector fields (DVFs). The Jacobian of the deformation gradient was calculated from DVFs, and the lung strain energy function was optimized to improve the tumor center of mass (TCM) motion simulation accuracy between respiratory phase 50% and 0%. The average TCM motion simulation error for the proposed strategy is 1.95 mm for eight patients. We observed 13% improvement in the TCM position prediction compared with the homogeneous Mooney-Rivlin modeling.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Algoritmos , Fenômenos Biomecânicos , Elasticidade , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/patologia , Modelos Biológicos , Movimento , Melhoria de Qualidade , Respiração
2.
Comput Biol Med ; 42(11): 1122-32, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23017828

RESUMO

The conductivity distribution around the thorax is altered during the cardiac cycle due to the blood perfusion, heart contraction and lung inflation. Previous studies showed that these bio-impedance changes are appropriate for non-invasive cardiac function imaging using Electrical Impedance Tomography (EIT) techniques. However, the spatial resolution is presently low. One of the main obstacles in cardiac imaging at the heart location is the large impedance variation of the lungs by respiration and muscles on the dorsal and posterior side of the body. In critical care units there is a potential to insert an internal electrode inside the esophagus directly behind the heart in the same plane of the external electrodes. The aim of the present study is to evaluate different current stimulation and measurement patterns with both external and internal electrodes. Analysis is performed with planar arrangement of 16 electrodes for a simulated 3D cylindrical tank and pig thorax model. In our study we evaluated current injection patterns consisting of adjacent, diagonal, trigonometric, and radial to the internal electrode. The performance of these arrangements was assessed using quantitative methods based on distinguishability, sensitivity and GREIT (Graz consensus Reconstruction algorithm for Electrical Impedance Tomography). Our evaluation shows that an internal electrode configuration based on the trigonometric injection patterns has better performance and improves pixel intensity of the small conductivity changes related to heart near 1.7 times in reconstructed images and also shows more stability with different levels of added noise. For the internal electrode, when we combined radial or adjacent injection with trigonometric injection pattern, we found an improvement in amplitude response. However, the combination of diagonal with trigonometric injection pattern deteriorated the shape deformation (correlation coefficient r=0.344) more than combination of radial and trigonometric injection (correlation coefficient r=0.836) for the perturbations in the area close to the center of the cylinder. We also find that trigonometric stimulation pattern performance is degraded in a realistic thorax model with anatomical asymmetry. For that reason we recommend using internal electrodes only for voltage measurements and as a reference electrode during trigonometric stimulation patterns in practical measurements.


Assuntos
Eletrodiagnóstico/instrumentação , Eletrodiagnóstico/métodos , Testes de Função Cardíaca/instrumentação , Testes de Função Cardíaca/métodos , Tomografia/instrumentação , Tomografia/métodos , Algoritmos , Animais , Condutividade Elétrica , Impedância Elétrica , Estimulação Elétrica , Eletrodos , Análise de Elementos Finitos , Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Processamento de Sinais Assistido por Computador , Suínos , Tórax/anatomia & histologia , Tórax/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...