1.
Bone Joint J ; 101-B(5): 565-572, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31038991

RESUMO

AIMS: The purpose of the present study was to compare patient-specific instrumentation (PSI) and conventional surgical instrumentation (CSI) for total knee arthroplasty (TKA) in terms of early implant migration, alignment, surgical resources, patient outcomes, and costs. PATIENTS AND METHODS: The study was a prospective, randomized controlled trial of 50 patients undergoing TKA. There were 25 patients in each of the PSI and CSI groups. There were 12 male patients in the PSI group and seven male patients in the CSI group. The patients had a mean age of 69.0 years (sd 8.4) in the PSI group and 69.4 years (sd 8.4) in the CSI group. All patients received the same TKA implant. Intraoperative surgical resources and any surgical waste generated were recorded. Patients underwent radiostereometric analysis (RSA) studies to measure femoral and tibial component migration over two years. Outcome measures were recorded pre- and postoperatively. Overall costs were calculated for each group. RESULTS: There were no differences (p > 0.05) in any measurement of migration at two years for either the tibial or femoral components. Movement between one and two years was < 0.2 mm, indicating stable fixation. There were no differences in coronal or sagittal alignment between the two groups. The PSI group took a mean 6.1 minutes longer (p = 0.04) and used a mean 3.4 less trays (p < 0.0001). Total waste generated was similar (10 kg) between the two groups. The PSI group cost a mean CAD$1787 more per case (p < 0.01). CONCLUSION: RSA criteria suggest that both groups will have revision rates of approximately 3% at five years. The advantages of PSI were minimal or absent for surgical resources used and waste eliminated, and for meeting target alignment, yet had significantly greater costs. Therefore, we conclude that PSI may not offer any advantage over CSI for routine primary TKA cases. Cite this article: Bone Joint J 2019;101-B:565-572.


Assuntos
Artroplastia do Joelho/instrumentação , Atenção à Saúde/estatística & dados numéricos , Custos de Cuidados de Saúde/estatística & dados numéricos , Prótese do Joelho/efeitos adversos , Idoso , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/economia , Canadá , Atenção à Saúde/economia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
2.
Bone Joint J ; 98-B(5): 616-21, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27143731

RESUMO

AIMS: The purpose of the present study was to examine the long-term fixation of a cemented fixed-bearing polished titanium tibial baseplate (Genesis ll). PATIENTS AND METHODS: Patients enrolled in a previous two-year prospective trial (n = 35) were recalled at ten years. Available patients (n = 15) underwent radiostereometric analysis (RSA) imaging in a supine position using a conventional RSA protocol. Migration of the tibial component in all planes was compared between initial and ten-year follow-up. Outcome scores including the Knee Society Score, Western Ontario and McMaster Universities Arthritis Index, 12-item Short Form Health Survey, Forgotten Joint Score, and University of California, Los Angeles Activity Score were recorded. RESULTS: At ten years, the mean migration of the tibial component was less than 0.1 mm and 0.1° in all planes relative to the post-operative RSA exam. Maximum total point movement increased with time (p = 0.002) from 0.23 mm (sd 0.18) at six weeks to 0.42 mm (sd 0.20) at ten years. CONCLUSION: The low level of tibial baseplate migration found in the present study correlates to the low rate of revision for this implant as reported in individual studies and in joint replacement registries. TAKE HOME MESSAGE: Overall, the implant was found to be well fixed at ten years, supporting its continued clinical use and the predictive power of RSA for determining long-term fixation of implants. Cite this article: Bone Joint J 2016;98-B:616-21.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Idoso , Feminino , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Masculino , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Análise Radioestereométrica , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Titânio