Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz Dent J ; 26(4): 398-403, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26312980

RESUMO

Failures may occur in the connections of dental implants, especially in external hexagon (EH). Due to the deformations in this portion of implants, this study aimed to evaluate the levels of deformation of EH connections subjected to internal toque. Two types of implants were used: N group and S group. Torques of 0, 32, 45, 60 and 80 Ncm were applied to the N group, and torques of 0, 30, 40, 60 and infinite Ncm were applied to the S group implants. The internal distance (ID), internal area (IA) and external area (EA) of the EH were obtained from digital pictures, which were analyzed by a specific software. Statistical analysis was performed by the Scott-Knott test. The results showed that the higher the torque applied, the greater were the changes in the evaluated dimensions in both groups. In the S group, torque levels equal or greater than 40 Ncm and 30 Ncm caused greater deformation of EA and IA respectively, while in the N group, torque levels equal or greater than 60 Ncm and 32 Ncm caused greater deformation of EA and IA respectively. Levels of deformation were greater in the S group as compared with the N group. These findings suggest that the IA, EA and ID of the EH may be affected by different internal torque levels.


Assuntos
Implantes Dentários , Torque , Humanos
2.
Int J Oral Maxillofac Implants ; 30(4): 789-99, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26252030

RESUMO

PURPOSE: Because the microtopography of titanium implants influences the biomaterial-tissue interaction, surface microtexturing treatments are frequently used for dental implants. However, surface treatment alone may not determine the final microtopography of a dental implant, which can also be influenced by the implant macrogeometry. This work analyzed the effects on surface roughness parameters of the same treatment applied by the same manufacturer to implants with differing macro-designs. MATERIALS AND METHODS: Three groups of titanium implants with different macro-designs were investigated using laser interferometry and scanning electron microscopy. Relevant surface roughness parameters were calculated for different regions of each implant. Two flat disks (treated and untreated) were also investigated for comparison. RESULTS: The tops of the threads and the nonthreaded regions of all implants had very similar roughness parameters, independent of the geometry of the implant, which were also very similar to those of flat disks treated with the same process. In contrast, the flanks and valleys of the threads presented larger irregularities (Sa) with higher slopes (Sdq) and larger developed surface areas (Sdr) on all implants, particularly for implants with threads with smaller heights. The flanks and valleys displayed stronger textures (Str), particularly on the implants with threads with larger internal angles. CONCLUSION: Parameters associated with the height of the irregularities (Sa), the slope of the asperities (Sdq), the presence of a surface texture (Str), and the developed surface area of the irregularities (Sdr) were significantly affected by the macrogeometry of the implants. Flat disks subjected to the same surface treatment as dental implants reproduced only the surface topography of the flat regions of the implants.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária , Titânio , Condicionamento Ácido do Dente , Materiais Biocompatíveis , Humanos , Interferometria , Microscopia Eletrônica de Varredura , Propriedades de Superfície
3.
Braz. dent. j ; 26(4): 398-403, July-Aug. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-756384

RESUMO

Failures may occur in the connections of dental implants, especially in external hexagon (EH). Due to the deformations in this portion of implants, this study aimed to evaluate the levels of deformation of EH connections subjected to internal toque. Two types of implants were used: N group and S group. Torques of 0, 32, 45, 60 and 80 Ncm were applied to the N group, and torques of 0, 30, 40, 60 and infinite Ncm were applied to the S group implants. The internal distance (ID), internal area (IA) and external area (EA) of the EH were obtained from digital pictures, which were analyzed by a specific software. Statistical analysis was performed by the Scott-Knott test. The results showed that the higher the torque applied, the greater were the changes in the evaluated dimensions in both groups. In the S group, torque levels equal or greater than 40 Ncm and 30 Ncm caused greater deformation of EA and IA respectively, while in the N group, torque levels equal or greater than 60 Ncm and 32 Ncm caused greater deformation of EA and IA respectively. Levels of deformation were greater in the S group as compared with the N group. These findings suggest that the IA, EA and ID of the EH may be affected by different internal torque levels.

.

Falhas podem ocorrer em conexões de implantes dentários, em especial em hexágonos externos (EH). Devido à ocorrência de deformação nesta porção dos implantes, este estudo objetivou avaliar os níveis de deformação de conexões EH submetidas ao torque interno. Dois tipos de implantes foram utilizados: grupo N e grupo S. Foram aplicados torques de 0, 32, 45, 60 e 80 Ncm nos implantes do grupo N e torques de 0, 30, 40, 60 Ncm e infinito nos implantes do grupo S. Medidas referentes à distância interna (ID), área interna (AI) e área externa (AE) foram obtidas por meio de fotos digitais analisadas em software. A análise estatística foi feita pelo teste de Scott-Knott. Os resultados demonstraram que quanto maior o torque aplicado, maior a alteração de todas as dimensões avaliadas em ambos os grupos. No grupo S, torques iguais ou superiores a 40 Ncm e 30 Ncm causaram maior deformação na AE e AI respectivamente, enquanto no grupo N, torques iguais ou superiores a 60 Ncm e 32 Ncm causaram maior deformação na AE e AI respectivamente. Os níveis de deformação foram maiores no grupo S em comparação ao grupo N. Nossos resultados indicam que a AI, a AE e a DI do EH podem ser influenciadas pelos diferentes torques internos.

.


Assuntos
Humanos , Implantes Dentários , Torque
4.
J Oral Implantol ; 41(1): 3-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23397888

RESUMO

The aim of this study was to analyze the effect of the separation of prosthetic crowns from fixed partial dentures by means of stress gradient evaluation. Three photoelastic models were created to examine contiguous implants with varying contact between the crowns (contact point [CP], contact surface [CS], splinted [SP]). The SP group presented the best results, followed by the CS group, indicating that the use of splinted prosthetic crowns and crowns with broad surface contacts is viable when considering the stress values.


Assuntos
Coroas , Prótese Dentária Fixada por Implante , Planejamento de Dentadura , Prótese Parcial Fixa , Algoritmos , Processo Alveolar/fisiopatologia , Fenômenos Biomecânicos , Força de Mordida , Arco Dental/fisiopatologia , Planejamento de Prótese Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Mandíbula/fisiopatologia , Estresse Mecânico , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...