1.
IEEE Trans Med Imaging ; 21(6): 703-7, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12166868

RESUMO

We studied dielectrical properties of canine myocardium during acute ischemia and hypoxia using dielectrical spectroscopy method at frequency spectrum from 100 kHz to 6 GHz. This study was conducted on a group of six canines with acute ischemia and seven canines with hypoxia. Hypoxia (10% for 30 min) decreases myocardial resistance (rho), while the dielectrical permittivity (epsilon') of the myocardial tissue remains statistically unchanged. Acute ischemia for 2 hr causes significant frequency-dependent changes in both epsilon' and rho of myocardial tissue. Myocardial resistance increases, while the sign and amplitude of changes in the myocardial epsilon' are frequency and time dependent. These observations open up an opportunity for assessing the properties of myocardial tissue using dielectrical spectroscopy as well as noninvasively with the help of imaging methods based on electrical impedance and microwave tomography.


Assuntos
Impedância Elétrica , Coração/fisiopatologia , Hipóxia/fisiopatologia , Isquemia Miocárdica/fisiopatologia , Análise Espectral/métodos , Doença Aguda , Animais , Cães , Campos Eletromagnéticos , Hipóxia/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
IEEE Trans Biomed Eng ; 49(1): 55-63, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11794772

RESUMO

The purpose of this study was to construct a microwave tomographic system capable of conducting experiments with whole scale biological objects and to demonstrate the feasibility of microwave tomography for imaging such objects using a canine model. Experiments were conducted using a three-dimensional (3-D) microwave tomographic system with working chamber dimensions of 120 cm in diameter and 135 cm in height. The operating frequency was 0.9 GHz. The object under study was located in the central area of the tomographic chamber filled with a salt solution. Experimentally measured attenuation of the electromagnetic field through the thorax was about -120 dB. To obtain images, we used various two-dimensional and 3-D reconstruction schemes. Images of the canine were obtained. In spite of imperfections, the images represent a significant milestone in the development of microwave tomography for whole body imaging and demonstrate its feasibility.