Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 6(10): 4079-87, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26504655

RESUMO

In this work we demonstrate optical trapping and manipulation of microparticles suspended in water due to laser-induced convection currents. Convection currents are generated due to laser light absorption in an hydrogenated amorphous silicon (a:Si-H) thin film. The particles are dragged towards the beam's center by the convection currents (Stokes drag force) allowing trapping with powers as low as 0.8 mW. However, for powers >3 mW trapped particles form a ring around the beam due to two competing forces: Stokes drag and thermo-photophoretic forces. Additionally, we show that dynamic beam shaping can be used to trap and manipulate multiple particles by photophotophoresis without the need of lithographically created resistive heaters.

2.
J Pediatr ; 123(6): 963-8, 1993 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8229531

RESUMO

To obtain normal data on arterial oxygen saturation as measured by pulse oximetry (SpO2; Nellcor N200), we obtained 12-hour tape recordings of SpO2, photoplethysmographic waveforms, instantaneous pulse rate, and observations of breathing movements on 55 preterm neonates (25 girls) who had been admitted to one of four special care baby units but had no signs of respiratory distress and were breathing room air at 24 hours of age. Their median gestational age at birth was 35 weeks (range, 30 to 36), and their median age at the time of study 1 day (range, 1 to 7). Median baseline SpO2, measured only during regular breathing, was 99.4% (range, 90.7 to 100; 5th percentile, 95.5). Ten recordings (18%) contained a total of 83 episodes of desaturation (defined as a fall in SpO2 to < or = 80% for > or = 4 seconds). The 95th percentile for desaturation frequency was eight per recording. One infant had 55 episodes of desaturation and thus accounted for two thirds of all episodes observed. Only one of the episodes of desaturation in this infant, and none of those in the other nine infants, had been noted clinically, nor had the abnormally low baseline SpO2 (90.7%) in one infant. Baseline SpO2 in these nondistressed preterm neonates was higher than might be expected, given the SpO2 levels currently recommended for preterm infants with respiratory failure. A minority of infants, however, had a low baseline SpO2 or a high frequency of episodes of desaturation, the potential effects of which remain to be determined.


Assuntos
Recém-Nascido Prematuro/fisiologia , Oxigênio/sangue , Artérias , Feminino , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Oximetria , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA