Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 62(2): 476-87, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19488992

RESUMO

Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass perfusion MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and H(2)(15)O positron emission tomography (PET) imaging. Calculations of hemodynamic parameters were based on a one-compartment model (MR) and a two-compartment model (PET). Simulations showed a significant error when assuming a linear relation between MR SI and CA dose in the arterial input function (AIF), even at low doses of 0.025 mmol/kg body weight (BW). To correct for nonlinearity, a calibration curve was calculated on the basis of the signal equation. The required accuracy of equation parameters (like longitudinal relaxation time) was evaluated. Error analysis estimates <5% over-/underestimation of the corrected SI. Comparison of PET and MR flow values yielded a significant correlation (P < 0.001) in dorsal regions where signal-to-noise ratio (SNR) was sufficient. Changes in PBF due to the correction method were significant (P < 0.001) and resulted in a better agreement: mean values (standard deviation) in units of ml/min/100 ml lung tissue were 59 (15) for PET, 112 (28) for uncorrected MRI, and 80 (21) for corrected MRI.


Assuntos
Artefatos , Gadolínio DTPA , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Tomografia por Emissão de Pósitrons/métodos , Circulação Pulmonar/fisiologia , Animais , Meios de Contraste , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Água
2.
Eur Radiol ; 17(1): 11-21, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16838142

RESUMO

Chronic thromboembolic pulmonary hypertension (CTEPH) is a severe disease that has been ignored for a long time. However, with the development of improved therapeutic modalities, cardiologists and thoracic surgeons have shown increasing interest in the diagnostic work-up of this entity. The diagnosis and management of chronic thromboembolic pulmonary hypertension require a multidisciplinary approach involving the specialties of pulmonary medicine, cardiology, radiology, anesthesiology and thoracic surgery. With this approach, pulmonary endarterectomy (PEA) can be performed with an acceptable mortality rate. This review article describes the developments in magnetic resonance (MR) imaging techniques for the diagnosis of chronic thromboembolic pulmonary hypertension. Techniques include contrast-enhanced MR angiography (ce-MRA), MR perfusion imaging, phase-contrast imaging of the great vessels, cine imaging of the heart and combined perfusion-ventilation MR imaging with hyperpolarized noble gases. It is anticipated that MR imaging will play a central role in the initial diagnosis and follow-up of patients with CTEPH.


Assuntos
Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico , Imageamento por Ressonância Magnética , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Doença Crônica , Humanos , Hipertensão Pulmonar/fisiopatologia , Circulação Pulmonar , Embolia Pulmonar/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...