Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sens Diagn ; 2(6): 1623-1637, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-38013763

RESUMO

Measuring the complex processes of blood coagulation, haemostasis and thrombosis that are central to cardiovascular health and disease typically requires a choice between high-resolution low-throughput laboratory assays, or simpler less quantitative tests. We propose combining mass-produced microfluidic devices with open-source robotic instrumentation to enable rapid development of affordable and portable, yet high-throughput and performance haematological testing. A time- and distance-resolved fluid flow analysis by Raspberry Pi imaging integrated with controlled sample addition and illumination, enabled simultaneous tracking of capillary rise in 120 individual capillaries (∼160, 200 or 270 µm internal diameter), in 12 parallel disposable devices. We found time-resolved tracking of capillary rise in each individual microcapillary provides quantitative information about fluid properties and most importantly enables quantitation of dynamic changes in these properties following stimulation. Fluid properties were derived from flow kinetics using a pressure balance model validated with glycerol-water mixtures and blood components. Time-resolved imaging revealed fluid properties that were harder to determine from a single endpoint image or equilibrium analysis alone. Surprisingly, instantaneous superficial fluid velocity during capillary rise was found to be largely independent of capillary diameter at initial time points. We tested if blood function could be measured dynamically by stimulating blood with thrombin to trigger activation of global haemostasis. Thrombin stimulation slowed vertical fluid velocity consistent with a dynamic increase in viscosity. The dynamics were concentration-dependent, with highest doses reducing flow velocity faster (within 10 s) than lower doses (10-30 s). This open-source imaging instrumentation expands the capability of affordable microfluidic devices for haematological testing, towards high-throughput multi-parameter blood analysis needed to understand and improve cardiovascular health.

2.
Sens Diagn ; 2(3): 736-750, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37216011

RESUMO

Innovation in infection based point-of-care (PoC) diagnostics is vital to avoid unnecessary use of antibiotics and the development of antimicrobial resistance. Several groups including our research team have in recent years successfully miniaturised phenotypic antibiotic susceptibility tests (AST) of isolated bacterial strains, providing validation that miniaturised AST can match conventional microbiological methods. Some studies have also shown the feasibility of direct testing (without isolation or purification), specifically for urinary tract infections, paving the way for direct microfluidic AST systems at PoC. As rate of bacteria growth is intrinsically linked to the temperature of incubation, transferring miniaturised AST nearer the patient requires building new capabilities in terms of temperature control at PoC, furthermore widespread clinical use will require mass-manufacturing of microfluidic test strips and direct testing of urine samples. This study shows for the first-time application of microcapillary antibiotic susceptibility testing (mcAST) directly from clinical samples, using minimal equipment and simple liquid handling, and with kinetics of growth recorded using a smartphone camera. A complete PoC-mcAST system was presented and tested using 12 clinical samples sent to a clinical laboratory for microbiological analysis. The test showed 100% accuracy for determining bacteria in urine above the clinical threshold (5 out of 12 positive) and achieved 95% categorical agreement for 5 positive urines tested with 4 antibiotics (nitrofurantoin, ciprofloxacin, trimethoprim and cephalexin) within 6 h compared to the reference standard overnight AST method. A kinetic model is presented for metabolization of resazurin, demonstrating kinetics of degradation of resazurin in microcapillaries follow those observed for a microtiter plate, with time for AST dependent on the initial CFU ml-1 of uropathogenic bacteria in the urine sample. In addition, we show for the first time that use of air-drying for mass-manufacturing and deposition of AST reagents within the inner surface of mcAST strips matches results obtained with standard AST methods. These results take mcAST a step closer to clinical application, for example as PoC support for antibiotic prescription decisions within a day.

3.
Analyst ; 147(15): 3558-3569, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35801578

RESUMO

Antibiotic resistance is a major global challenge. Although microfluidic antibiotic susceptibility tests (AST) offer great potential for rapid and portable testing to inform correct antibiotic selection, the impact of miniaturisation on broth microdilution (BMD) is not fully understood. We developed a 10-plex microcapillary based broth microdilution using resazurin as a colorimetric indicator for bacterial growth. Each capillary had a 1 microlitre capillary volume, 100 times smaller than microplate broth microdilution. The microcapillary BMD was compared to an in-house standard microplate AST and commercial Vitek 2 system. When tested with 25 uropathogenic isolates (20 Escherichia coli and 5 Klebsiella pneumoniae) and 2 reference E. coli, these devices gave 96.1% (441/459 isolate/antibiotic combinations) categorical agreement, across 17 therapeutically beneficial antibiotics, compared to in-house microplate BMD with resazurin. A further 99 (50 E. coli and 49 K. pneumoniae) clinical isolates were tested against 10 antibiotics and showed 92.3% categorical agreement (914/990 isolate/antibiotic combinations) compared to the Vitek 2 measurements. These microcapillary tests showed excellent analytical agreement with existing AST methods. Furthermore, the small size and simple colour change can be recorded using a smartphone camera or it is feasible to follow growth kinetics using very simple, low-cost readers. The test strips used here are produced in large batches, allowing hundreds of multiplex tests to be made and tested rapidly. Demonstrating performance of miniaturised broth microdilution with clinical isolates paves the way for wider use of microfluidic AST.


Assuntos
Antibacterianos , Escherichia coli , Antibacterianos/farmacologia , Klebsiella pneumoniae , Testes de Sensibilidade Microbiana
4.
Lab Chip ; 22(15): 2820-2831, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35792607

RESUMO

Counting viable bacterial cells and functional bacteriophage is fundamental to microbiology underpinning research, surveillance, biopharmaceuticals and diagnostics. Colony forming unit (CFU) and plaque forming unit (PFU) counting still requires slow and laborious solid culture on agar in Petri dishes or plates. Here, we show that dip-stick microfluidic strips can be used without growth indicator dye for rapid and simple CFU ml-1 and PFU ml-1 measurement. We demonstrate for the first time that fluoropolymer microcapillaries combined with digital imaging allow bacteriophage plaques to be counted rapidly in a dip-and-test format. The microfluidic length scales offer a linear 1-dimensional alternative to a 2D solid agar medium surface, with colonies or plaques clearly visible as "dashes" or "gaps". An inexpensive open source darkfield biosensor system using Raspberry Pi imaging permits label-free detection and counting of colonies or plaques within 4-8 hours in a linear, liquid matrix within ∼200 µm inner diameter microcapillaries. We obtained full quantitative agreement between 1D microfluidic colony counting in dipsticks versus conventional 2D solid agar Petri dish plates for S. aureus and E. coli, and for T2 phage and phage K, but up to 6 times faster. Time-lapse darkfield imaging permitted detailed kinetic analysis of colony growth in the microcapillaries, providing new insight into microfluidic microbiology and colony growth, not possible with Petri dishes. Surprisingly, whilst E. coli colonies appeared earlier, subsequent colony expansion was faster along the microcapillaries for S. aureus. This may be explained by the microenvironment offered for 1D colony growth within microcapillaries, linked to a mass balance between nutrient (glucose) diffusion and bacterial growth kinetics. Counting individual colonies in liquid medium was not possible for motile strains that spread rapidly along the capillary, however inclusion of soft agar inhibited spreading, making this new simple dip-and-test counting method applicable to both motile and non-motile bacteria. Label-free dipstick colony and plaque counting has potential for many analytical microbial tasks, and the innovation of 1D colony counting has relevance to other microfluidic microbiology.


Assuntos
Bacteriófagos , Ágar , Bactérias , Contagem de Colônia Microbiana , Escherichia coli , Cinética , Microfluídica , Staphylococcus aureus
5.
FEBS J ; 289(11): 3115-3131, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34995415

RESUMO

The polycaspase inhibitor Z-VAD-fmk acts as an inhibitor of peptide: N-glycanase (NGLY1), an endoglycosidase which cleaves N-linked glycans from glycoproteins exported from the endoplasmic reticulum (ER) during ER-associated degradation (ERAD). Both pharmacological N-glycanase inhibition by Z-VAD-fmk and siRNA-mediated knockdown (KD) of NGLY1 induce GFP-LC3-positive puncta in HEK 293 cells. The activation of ER stress markers or induction of reactive oxygen species (ROS) is not observed under either condition. Moreover, Ca2+ handling is unaffected when observing release from intracellular stores. Under conditions of pharmacological NGLY1 inhibition or NGLY1 KD, upregulation of autophagosome formation without impairment of autophagic flux is observed. Enrichment of autophagosomes by immunoprecipitation (IP) and mass spectrometry-based proteomic analysis reveals comparable autophagosomal protein content. Gene ontology analysis of proteins enriched in autophagosome IPs shows overrepresentation of factors involved in protein translation, localization and targeting, RNA degradation and protein complex disassembly. Upregulation of autophagy represents a cellular adaptation to NGLY1 inhibition or KD, and ATG13-deficient mouse embryonic fibroblasts (MEFs) show reduced viability under these conditions. In contrast, treatment with pan-caspase inhibitor, Q-VD-OPh, does not induce cellular autophagy. Therefore, experiments with Z-VAD-fmk are complicated by the effects of NGLY1 inhibition, including induction of autophagy, and Q-VD-OPh represents an alternative caspase inhibitor free from this limitation. ENZYMES: Peptide:N-glycanase1, Peptide-N(4)-(N-acetyl-beta-glucosaminyl)asparagine amidase [EC:3.5.1.52].


Assuntos
Fibroblastos , Proteômica , Animais , Autofagia , Caspases , Fibroblastos/metabolismo , Células HEK293 , Humanos , Camundongos , Peptídeo-N4-(N-acetil-beta-glucosaminil) Asparagina Amidase/química , Peptídeo-N4-(N-acetil-beta-glucosaminil) Asparagina Amidase/genética , Peptídeo-N4-(N-acetil-beta-glucosaminil) Asparagina Amidase/metabolismo , Peptídeos/metabolismo
6.
ACS Sens ; 6(12): 4338-4348, 2021 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-34854666

RESUMO

A range of biosensing techniques including immunoassays are routinely used for quantitation of analytes in biological samples and available in a range of formats, from centralized lab testing (e.g., microplate enzyme-linked immunosorbent assay (ELISA)) to automated point-of-care (POC) and lateral flow immunochromatographic tests. High analytical performance is intrinsically linked to the use of a sequence of reagent and washing steps, yet this is extremely challenging to deliver at the POC without a high level of fluidic control involving, e.g., automation, fluidic pumping, or manual fluid handling/pipetting. Here we introduce a microfluidic siphon concept that conceptualizes a multistep ″dipstick″ for quantitative, enzymatically amplified immunoassays using a strip of microporous or microbored material. We demonstrated that gravity-driven siphon flow can be realized in single-bore glass capillaries, a multibored microcapillary film, and a glass fiber porous membrane. In contrast to other POC devices proposed to date, the operation of the siphon is only dependent on the hydrostatic liquid pressure (gravity) and not capillary forces, and the unique stepwise approach to the delivery of the sample and immunoassay reagents results in zero dead volume in the device, no reagent overlap or carryover, and full start/stop fluid control. We demonstrated applications of a 10-bore microfluidic siphon as a portable ELISA system without compromised quantitative capabilities in two global diagnostic applications: (1) a four-plex sandwich ELISA for rapid smartphone dengue serotype identification by serotype-specific dengue virus NS1 antigen detection, relevant for acute dengue fever diagnosis, and (2) quantitation of anti-SARS-CoV-2 IgG and IgM titers in spiked serum samples. Diagnostic siphons provide the opportunity for high-performance immunoassay testing outside sophisticated laboratories, meeting the rapidly changing global clinical and public health needs.


Assuntos
COVID-19 , Microfluídica , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoensaio , SARS-CoV-2
7.
J Microbiol Methods ; 187: 106199, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33771524

RESUMO

Viable bacterial cell counting is fundamental to analytical microbiology and agar plate colony counting remains common yet laborious and slow. Here, we demonstrate two methods for counting bacteria using commercially available microfluidic devices. We show that accurate viable cell counting is possible using simple and easy 'dip and test' arrays of microcapillaries. Colorimetric and fluorescent growth detection both permit viable cell counting in microcapillaries either by limiting dilution into multiple microfluidic compartments using a single endpoint measurement, or alternatively by quantifying growth kinetics. The microcapillary devices are compatible with conventional 96 well plates and multichannel pipettes, expanding each microplate row into 120 individual 1 or 2 µL samples. At limiting dilution, counting the proportion of positive compartments permitted accurate calculation of gram-negative and gram-positive bacteria (E. coli and S. saprophyticus) at concentrations down to as low as 10 CFU/mL with almost 1:1 agreement with agar plate colony counts over four orders of magnitude. A smartphone camera was sufficient to record endpoint images of resazurin growth detection both colorimetrically and fluorescently. Viable cell counting of E. coli and S. saprophyticus was also possible through recording growth kinetics and determining the time taken to detect resazurin conversion. However, only the limiting dilution method remained consistent in the presence of urine matrix, as some interference in growth rate was observed when bacteria were spiked into higher concentrations of normal urine to simulate urinary tract infection patient samples. However, with the limiting dilution counting method endpoint growth was always detected even in the presence of 90% urine matrix, suggesting that this method might permit bacterial pathogen counting directly in clinical samples without agar plating.


Assuntos
Carga Bacteriana , Dispositivos Lab-On-A-Chip , Viabilidade Microbiana , Contagem de Colônia Microbiana , Colorimetria , Escherichia coli/crescimento & desenvolvimento , Humanos , Oxazinas , Fitas Reagentes , Smartphone , Staphylococcus saprophyticus/crescimento & desenvolvimento , Infecções Urinárias/microbiologia , Urina/microbiologia , Xantenos
8.
PLoS One ; 14(11): e0224878, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31743346

RESUMO

Growth in open-source hardware designs combined with the low-cost of high performance optoelectronic and robotics components has supported a resurgence of in-house custom lab equipment development. We describe a low cost (below $700), open-source, fully customizable high-throughput imaging system for analytical microbiology applications. The system comprises a Raspberry Pi camera mounted on an aluminium extrusion frame with 3D-printed joints controlled by an Arduino microcontroller running open-source Repetier Host Firmware. The camera position is controlled by simple G-code scripts supplied from a Raspberry Pi singleboard computer and allow customized time-lapse imaging of microdevices over a large imaging area. Open-source OctoPrint software allows remote access and control. This simple yet effective design allows high-throughput microbiology testing in multiple formats including formats for bacterial motility, colony growth, microtitre plates and microfluidic devices termed 'lab-on-a-comb' to screen the effects of different culture media components and antibiotics on bacterial growth. The open-source robot design allows customization of the size of the imaging area; the current design has an imaging area of ~420 × 300mm, which allows 29 'lab-on-a-comb' devices to be imaged which is equivalent 3480 individual 1µl samples. The system can also be modified for fluorescence detection using LED and emission filters embedded on the PiCam for more sensitive detection of bacterial growth using fluorescent dyes.


Assuntos
Ensaios de Triagem em Larga Escala , Técnicas Microbiológicas , Impressão Tridimensional , Robótica , Imagem com Lapso de Tempo , Animais , Automação , Bactérias/isolamento & purificação , Bovinos , Resistência Microbiana a Medicamentos , Feminino , Fluorescência , Mastite Bovina/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...