1.
Catheter Cardiovasc Interv ; 100(2): 207-213, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35621166

RESUMO

OBJECTIVE: This study was performed to investigate the efficacy and safety of robotic diagnostic coronary angiography. BACKGROUND: Robotic percutaneous coronary intervention is associated with marked reductions in physician radiation exposure. Development of robotic diagnostic coronary angiography might similarly impact occupational safety. METHODS: Stable patients referred for coronary angiography were prospectively enrolled. After obtaining vascular access, diagnostic catheters were manually advanced over a wire to the ascending aorta. All subsequent catheter movements were performed robotically. The primary endpoint was procedural success, defined as robotic completion of coronary angiography without conversion to a manual procedure and the absence of procedural major adverse cardiovascular events (MACE-cardiac death, cardiac arrest, or stroke) and major angiographic complications (coronary/aortic dissection or embolization). The primary hypothesis was that the observed rate of the primary endpoint, evaluated at the completion of coronary angiography, would meet a pre-specified performance goal of 74.5%. RESULTS: Among 46 consecutive patients (age 67 ± 12 years; 69.6% male), diagnostic coronary angiography was completed robotically in all cases without the need for manual conversion and without any MACE or major angiographic complications. Thus, procedural success was 100%, which was significantly higher than the pre-specified performance goal (p < 0.001). Robotic coronary angiography was completed using 2 [2, 3] catheters per case with a median procedural time of 15 [11, 20] minutes. CONCLUSIONS: Robotic diagnostic coronary angiography was performed with 100% procedural success and no observed complications. These results support the performance of future studies to further explore robotic coronary angiography.


Assuntos
Intervenção Coronária Percutânea , Robótica , Idoso , Angiografia Coronária/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Stents , Resultado do Tratamento
2.
Cardiovasc Revasc Med ; 19(8): 929-933, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30077495

RESUMO

BACKGROUND: The impact of patient obesity on scrub technologist radiation dose during coronary angiography has not been adequately studied. METHODS: Real-time radiation exposure data were prospectively collected during consecutive coronary angiography cases. Patient radiation dose was estimated by dose area product (DAP). Technologist radiation dose was recorded by a dosimeter as the personal dose equivalent (Hp (10)). Patients were categorized according to their body mass index (BMI): <25.0, lean; 25.0-29.9, overweight; ≥30.0, obese. The study had two phases: in Phase I (N = 351) standard radiation protection measures were used; and in Phase II (N = 268) standard radiation protection measures were combined with an accessory lead shield placed between the technologist and patient. RESULTS: In 619 consecutive coronary angiography procedures, significant increases in patient and technologist radiation doses were observed across increasing patient BMI categories (p < 0.001 for both). Compared to lean patients, patient obesity was associated with a 1.7-fold increase in DAP (73.0 [52.7, 127.5] mGy × cm2 vs 43.6 [25.1, 65.7] mGy × cm2, p < 0.001) and a 1.8-fold increase in technologist radiation dose (1.1 [0.3, 2.7] µSv vs 0.6 [0.1, 1.6] µSv, p < 0.001). Compared to Phase I, use of an accessory lead shield in Phase II was associated with a 62.5% reduction in technologist radiation dose when used in obese patients (p < 0.001). CONCLUSIONS: During coronary angiography procedures, patient obesity was associated with a significant increase in scrub technologist radiation dose. This increase in technologist radiation dose in obese patients may be mitigated by use of an accessory lead shield.


Assuntos
Obesidade/complicações , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Exposição à Radiação/efeitos adversos , Lesões por Radiação/epidemiologia , Medição de Risco/métodos , Idoso , Angiografia Coronária/métodos , Feminino , Seguimentos , Humanos , Incidência , Masculino , Estudos Prospectivos , Doses de Radiação , Lesões por Radiação/diagnóstico , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação , Proteção Radiológica/métodos , Fatores de Risco , Estados Unidos/epidemiologia