Med Phys ; 47(6): 2380-2391, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32160322

RESUMO

PURPOSE: Many methods are available to segment structural magnetic resonance (MR) images of the brain into different tissue types. These have generally been developed for research purposes but there is some clinical use in the diagnosis of neurodegenerative diseases such as dementia. The potential exists for computed tomography (CT) segmentation to be used in place of MRI segmentation, but this will require a method to verify the accuracy of CT processing, particularly if algorithms developed for MR are used, as MR has notably greater tissue contrast. METHODS: To investigate these issues we have created a three-dimensional (3D) printed brain with realistic Hounsfield unit (HU) values based on tissue maps segmented directly from an individual T1 MRI scan of a normal subject. Several T1 MRI scans of normal subjects from the ADNI database were segmented using SPM12 and used to create stereolithography files of different tissues for 3D printing. The attenuation properties of several material blends were investigated, and three suitable formulations were used to print an object expected to have realistic geometry and attenuation properties. A skull was simulated by coating the object with plaster of Paris impregnated bandages. Using two CT scanners, the realism of the phantom was assessed by the measurement of HU values, SPM12 segmentation and comparison with the source data used to create the phantom. RESULTS: Realistic relative HU values were measured although a subtraction of 60 was required to obtain equivalence with the expected values (gray matter 32.9-35.8 phantom, 29.9-34.2 literature). Segmentation of images acquired at different kVps/mAs showed excellent agreement with the source data (Dice Similarity Coefficient 0.79 for gray matter). The performance of two scanners with two segmentation methods was compared, with the scanners found to have similar performance and with one segmentation method clearly superior to the other. CONCLUSION: The ability to use 3D printing to create a realistic (in terms of geometry and attenuation properties) head phantom has been demonstrated and used in an initial assessment of CT segmentation accuracy using freely available software developed for MRI.


Assuntos
Neuroimagem , Tomografia Computadorizada por Raios X , Cabeça/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
2.
Nucl Med Commun ; 39(3): 268-275, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29346173

RESUMO

The Alderson striatal phantom is frequently used to assess I-FP-CIT (Ioflupane) image quality and to test semi-quantification software. However, its design is associated with a number of limitations, in particular: unrealistic image appearances and inflexibility. A new physical phantom approach is proposed on the basis of subresolution phantom technology. The design incorporates thin slabs of attenuating material generated through additive manufacturing, and paper sheets with radioactive ink patterns printed on their surface, created with a conventional inkjet printer. The paper sheets and attenuating slabs are interleaved before scanning. Use of thin layers ensures that they cannot be individually resolved on reconstructed images. An investigation was carried out to demonstrate the performance of such a phantom in producing simplified I-FP-CIT uptake patterns. Single photon emission computed tomography imaging was carried out on an assembled phantom designed to mimic a healthy patient. Striatal binding ratio results and linear striatal dimensions were calculated from the reconstructed data and compared with that of 22 clinical patients without evidence of Parkinsonian syndrome, determined from clinical follow-up. Striatal binding ratio results for the fully assembled phantom were: 3.1, 3.3, 2.9 and 2.6 for the right caudate, left caudate, right putamen and right caudate, respectively. All were within two SDs of results derived from a cohort of clinical patients. Medial-lateral and anterior-posterior dimensions of the simulated striata were also within the range of values seen in clinical data. This work provides the foundation for the generation of a range of more clinically realistic, physical phantoms.


Assuntos
Análise Custo-Benefício , Imagens de Fantasmas/economia , Diagnóstico por Imagem , Impressão , Tropanos
3.
Med Phys ; 43(9): 5020, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27587032

RESUMO

PURPOSE: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. METHODS: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding (99m)Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. RESULTS: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. CONCLUSIONS: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.


Assuntos
Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Impressão Tridimensional , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Imageamento por Ressonância Magnética
4.
Ann Am Thorac Soc ; 13(3): 350-5, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26710080

RESUMO

RATIONALE: The definition of primary spontaneous pneumothorax excludes patients with known lung disease; however, the assumption that the underlying lung is normal in these patients is increasingly contentious. OBJECTIVES: The purpose of this study was to assess lung structure and compare the extent of emphysema in patients with primary versus secondary spontaneous pneumothorax and to patients with no pneumothorax in an otherwise comparable control group. METHODS: We identified patients treated for pneumothorax by screening inpatient and outpatient medical records at one medical center in the United Kingdom. From this group, 20 patients had no clinically apparent underlying lung disease and were classified as having a primary spontaneous pneumothorax, and 20 patients were classified as having a secondary spontaneous pneumothorax. We assembled a control group composed of 40 subjects matched for age and smoking history who had a unilateral pleural effusion or were suspected to have a thoracic malignancy and had a chest computed tomography scan suitable for quantitative analysis. Demographics and smoking histories were collected. Quantitative evaluation of low-attenuation areas of the lung on computed tomography imaging was performed using semiautomated software, and the extent of emphysema-like destruction was assessed visually. MEASUREMENTS AND MAIN RESULTS: The extent of emphysema and percentage of low-attenuation areas was greater for patients with primary spontaneous pneumothorax than for control subjects matched for age and smoking history (median, 0.25 vs. 0.00%; P = 0.019) and was also higher for patients with secondary pneumothorax than those with primary spontaneous pneumothorax (16.15 vs. 0.25%, P < 0.001). Patients with primary pneumothorax who smoked had significantly greater low-attenuation area than patients with primary pneumothorax who were nonsmokers (0.7 vs. 0.1%, P = 0.034). CONCLUSIONS: The majority of patients with primary spontaneous pneumothorax had quantifiable evidence of parenchymal destruction and emphysema. The exclusion of patients with underlying lung disease from the definition of primary spontaneous pneumothorax should be reappraised.


Assuntos
Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumotórax/complicações , Pneumotórax/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fumar , Tomografia Computadorizada por Raios X , Reino Unido , Adulto Jovem
5.
J Am Coll Cardiol ; 47(9): 1840-5, 2006 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-16682310

RESUMO

OBJECTIVES: The aim of this study was to quantify and compare effective doses from conventional angiography and multislice computed tomography (MSCT) coronary angiography using a 16-slice scanner. BACKGROUND: Multislice computed tomography is now a viable modality for cardiac imaging. However, for any diagnostic use of ionizing radiation, the risk to the patient must be considered and justified. METHODS: Multislice computed tomography angiography and conventional angiography were used to assess 180 patients with suspected coronary artery disease. Estimates of effective dose were derived from exposure data recorded for each patient examination. For each modality, a comparable calculation technique was used, based on Monte Carlo modeling of the standard Cristy phantom. RESULTS: In a subset of 91 directly comparable patients the mean effective dose for MSCT coronary angiography was 14.7 mSv (SD 2.2) and that for conventional angiography was 5.6 mSv (SD 3.6). A significant difference in effective dose was seen between the two protocols. CONCLUSIONS: The mean effective dose for MSCT coronary angiography was significantly higher than that for conventional angiography. As MSCT cardiac scanners become increasingly available, operators must be aware of the radiation dose and the factors that affect it.


Assuntos
Angiografia Coronária , Tomografia Computadorizada por Raios X , Doença das Coronárias/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação